21. Catheter introducers for rapid fluid resuscitation. Haynes BE, Carr FJ, Niemann JT. Ann Emerg Med; 1983 Oct; 12(10):606-9. PubMed ID: 6625261 [Abstract] [Full Text] [Related]
22. Does transfusion using a syringe infusion pump and small-gauge needle cause hemolysis? Wilcox GJ, Barnes A, Modanlou H. Transfusion; 1981 Oct; 21(6):750-1. PubMed ID: 7314226 [Abstract] [Full Text] [Related]
23. Confirmation of high blood flow rates through 150 mu filter/high-flow tubing. Iserson KV, Knauf MA. J Emerg Med; 1990 Oct; 8(6):689-91. PubMed ID: 2096162 [Abstract] [Full Text] [Related]
25. Flow rates of large animal fluid delivery systems used for high-volume crystalloid resuscitation. Nolen-Walston RD. J Vet Emerg Crit Care (San Antonio); 2012 Dec 17; 22(6):661-5. PubMed ID: 23216840 [Abstract] [Full Text] [Related]
26. Biocuff--a new pressure device for infusion bags. Mohr R, Dinbar I, Leibinsohn S, Elian Y. Crit Care Med; 1985 Dec 17; 13(12):1050-1. PubMed ID: 4064715 [Abstract] [Full Text] [Related]
27. Experience with a totally implantable venous device in children. Pegelow CH, Narvaez M, Toledano SR, Davis J, Oiticica C, Buckner D. Am J Dis Child; 1986 Jan 17; 140(1):69-71. PubMed ID: 3079946 [Abstract] [Full Text] [Related]
28. Prediction of flow capability in intravenous infusion systems: implications for fluid resuscitation. Philip BK, Philip JH. J Clin Monit; 1990 Apr 17; 6(2):113-7. PubMed ID: 2351999 [Abstract] [Full Text] [Related]
29. Effect of External Pressure and Catheter Gauge on Flow Rate, Kinetic Energy, and Endothelial Injury During Intravenous Fluid Administration in a Rabbit Model. Hu MH, Chan WH, Chen YC, Cherng CH, Lin CK, Tsai CS, Chou YC, Huang GS. Shock; 2016 Jan 17; 45(1):98-103. PubMed ID: 26674456 [Abstract] [Full Text] [Related]
30. New guide wire for high-flow infusion. Barnhart W, Snidow JJ, Smith TP, Castaneda F, Nakagawa N, Cragg AH. Radiology; 1990 Mar 17; 174(3 Pt 2):1058-9. PubMed ID: 2305092 [Abstract] [Full Text] [Related]
31. [Technical constraints in rapid vascular fluid replacement]. Noirot MT, Freysz M, Letourneau B, Defrance N, Angue M. Ann Fr Anesth Reanim; 1990 Mar 17; 9(5):433-42. PubMed ID: 2240696 [Abstract] [Full Text] [Related]
32. Maximum infusion rates and CVP accuracy during high-flow delivery through multilumen catheters. Ikeda S, Schweiss JF. Crit Care Med; 1985 Jul 17; 13(7):586-8. PubMed ID: 4006500 [Abstract] [Full Text] [Related]
33. Larger catheter sheath introducers and their side port functional gauge. Benumof JL, Trousdale FR, Alfery DD, Ozaki GT. Anesth Analg; 1981 Apr 17; 60(4):216-7. PubMed ID: 7193999 [No Abstract] [Full Text] [Related]
34. Hydrodynamic evaluation of intravenous infusion systems. Elad D, Zaretsky U, Heller O. Ann Emerg Med; 1994 Mar 17; 23(3):457-63. PubMed ID: 8135419 [Abstract] [Full Text] [Related]
35. Substandard infusion sets, inadequate transfusion sets, weak bottle hangers and missing spoons and droppers. Kulkarni KB. Indian Pediatr; 1989 Nov 17; 26(11):1167-8. PubMed ID: 2630485 [No Abstract] [Full Text] [Related]
36. An In Vitro Assessment of the Efficacy of Various IV Cannulas for the Rapid IV Fluid Administration. Kamata M, Walia H, Hakim M, Tumin D, Tobias JD. Pediatr Crit Care Med; 2017 May 17; 18(5):e224-e228. PubMed ID: 28319488 [Abstract] [Full Text] [Related]