2. Optimization of platelet concentrate collection for continuous flow cell separation devices (CFCS). Hester JP, Ventura J. Ann Med Interne (Paris); 1988; 139 Suppl 1():7-10. PubMed ID: 3247996 [Abstract] [Full Text] [Related]
3. Platelet collection and transfusion using the fenwal CS-3000 cell separator. Katz AJ, Genco PV, Blumberg N, Snyder EL, Camp B, Morse EE. Transfusion; 1981; 21(5):560-3. PubMed ID: 7292585 [Abstract] [Full Text] [Related]
4. A critical review of platelet yield by Haemonetics 30 . Based on literature and own observations. Rosenkvist J, Holsøe E, Freiesleben E, Sørensen H. Scand J Haematol; 1980 Aug; 25(2):165-70. PubMed ID: 7466305 [Abstract] [Full Text] [Related]
5. Plateletpheresis concentrates produced in 30 minutes along with plasma and packed red cells: preliminary results. Valbonesi M, Frisoni R, Capra C, Lercari G, Fella M, Pittaluga P. J Clin Apher; 1988 Aug; 4(4):152-4. PubMed ID: 3220817 [Abstract] [Full Text] [Related]
6. Factors influencing yield of plateletpheresis using intermittent flow cell separator. DAS SS, Chaudhary RK, Shukla JS. Clin Lab Haematol; 2005 Oct; 27(5):316-9. PubMed ID: 16178912 [Abstract] [Full Text] [Related]
7. Determination in vivo viability of a transfused platelet product by corrected count increment and percentage platelet response. Thuku NW, Shikuku K, Mbugua A. Pan Afr Med J; 2017 Oct; 27():226. PubMed ID: 28979628 [Abstract] [Full Text] [Related]
8. Collection and transfusion of single donor platelets and their clinical response. Hester J, Ventura G. Infusionstherapie; 1989 Aug; 16 Suppl 2():4-9; discussion 28-9. PubMed ID: 2583843 [Abstract] [Full Text] [Related]
9. [The eccentriplate device on the Dideco Vivacell cell separator for the collection of platelets]. Andreu G, Gautheron A, Nicod-Tran A, Lecrubier C, Samama M. Ann Med Interne (Paris); 1988 Aug; 139 Suppl 1():13-7. PubMed ID: 3247982 [Abstract] [Full Text] [Related]
10. Effect of donor variables on yield in single donor plateletpheresis by continuous flow cell separator. Chaudhary R, Das SS, Khetan D, Sinha P. Transfus Apher Sci; 2006 Apr; 34(2):157-61. PubMed ID: 16510315 [Abstract] [Full Text] [Related]
11. Effective cell support by repeat plateletpheresis of related donors on the IBM 2997 cell separator. Langley JW, Spiva D, Hendren D, Orrell J. Am J Clin Pathol; 1981 Aug; 76(2):148-54. PubMed ID: 7270495 [Abstract] [Full Text] [Related]
12. Effectiveness of the haemonetics MCS cell separator in the collection of apheresis platelets. Keklik M, Keklik E, Korkmaz S, Aygun B, Arik F, Kilic O, Sarikoc M. Transfus Apher Sci; 2015 Dec; 53(3):396-8. PubMed ID: 26283175 [Abstract] [Full Text] [Related]
13. [Isolation and use of thrombocyte and leukocyte concentrates]. Kalinin NN. Probl Gematol Pereliv Krovi; 1980 Oct; 25(10):50. PubMed ID: 6999495 [No Abstract] [Full Text] [Related]
14. [A new separation protocol (DRBCP-F) for automated blood component donation with the MCS 3p cell separator for collection of leukocyte depleted erythrocyte concentrates and plasma]. Zeiler T, Kretschmer V. Beitr Infusionsther Transfusionsmed; 1997 Oct; 34():118-22. PubMed ID: 9417335 [Abstract] [Full Text] [Related]
16. Peripheral blood stem cell collection with reduced platelet loss to the patient/donor. Orlina AR, DeChristopher PJ, Conant JC, Catchatourian R, Cano P. J Clin Apher; 1995 Oct; 10(1):1-6. PubMed ID: 7601861 [Abstract] [Full Text] [Related]
17. Donor platelet response and product quality assurance in plateletpheresis. Lasky LC, Lin A, Kahn RA, McCullough J. Transfusion; 1981 Oct; 21(3):247-60. PubMed ID: 7233509 [Abstract] [Full Text] [Related]
18. Donor selection criteria to maximize double platelet products (DPP) by platelet apheresis. Wollersheim J, Dautzenberg M, van de Griendt A, Sybesma B. Transfus Apher Sci; 2006 Apr; 34(2):179-86. PubMed ID: 16574489 [Abstract] [Full Text] [Related]
19. Fuji surge technique and continuous in-line filtration to improve the quality of single donor platelet concentrates. Moog R. J Clin Apher; 2002 Apr; 17(4):199-203. PubMed ID: 12494413 [Abstract] [Full Text] [Related]
20. A comparison of platelets prepared by the Haemonetics Model 30 and multiunit bag plateletpheresis. Daly PA, Schiffer CA, Aisner J, Wiernik PH. Transfusion; 1979 Apr; 19(6):778-81. PubMed ID: 524435 [Abstract] [Full Text] [Related] Page: [Next] [New Search]