These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Closed intramedullary rodding of pathologic fractures with supplemental cement. Kunec JR, Lewis RJ. Clin Orthop Relat Res; 1984 Sep; (188):183-6. PubMed ID: 6467713 [Abstract] [Full Text] [Related]
3. Performance evaluation of a cement-augmented intramedullary fixation system for pathologic lesions of the femoral shaft. Miller GJ, Vander Griend RA, Blake WP, Springfield DS. Clin Orthop Relat Res; 1987 Aug; (221):246-54. PubMed ID: 3608306 [Abstract] [Full Text] [Related]
4. A new technique for cement augmentation of the sliding hip screw in proximal femur fractures. Stoffel KK, Leys T, Damen N, Nicholls RL, Kuster MS. Clin Biomech (Bristol); 2008 Jan; 23(1):45-51. PubMed ID: 17964016 [Abstract] [Full Text] [Related]
5. The strength of metal reinforced methylmethacrylate fixation of pathologic fractures. Wang GJ, Reger SI, Maffeo C, McLaughlin RE, Stamp WG. Clin Orthop Relat Res; 1978 Sep; (135):287-90. PubMed ID: 709941 [Abstract] [Full Text] [Related]
12. Sustained pressurization of polymethylmethacrylate: a comparison of low- and moderate-viscosity bone cements. Bean DJ, Hollis JM, Woo SL, Convery FR. J Orthop Res; 1988 Jun; 6(4):580-4. PubMed ID: 3379511 [Abstract] [Full Text] [Related]
13. Indications for use of the long Gamma nail. Rodriguez Alvarez J, Casteleiro Gonzolez C, Laguna Aranda R, Ferrer Blanco M, Cuervo Dehesa M. Clin Orthop Relat Res; 1998 May; (350):62-6. PubMed ID: 9602801 [Abstract] [Full Text] [Related]
14. A cement fixation system for total hip arthroplasty. Oh I, Harris WH. Clin Orthop Relat Res; 1982 Apr; (164):221-9. PubMed ID: 7067290 [Abstract] [Full Text] [Related]
15. [Improvement in the primary stability of the dynamic hip screw osteosynthesis in unstable, pertrochanteric femoral fractures of osteoporotic bones by a new glass ionomer cement]. Claes L, Becker C, Simnacher M, Hoellen I. Unfallchirurg; 1995 Mar; 98(3):118-23. PubMed ID: 7754397 [Abstract] [Full Text] [Related]
16. Mechanical characteristics of the bone-graft-cement interface after impaction allografting. Frei H, Mitchell P, Masri BA, Duncan CP, Oxland TR. J Orthop Res; 2005 Jan; 23(1):9-17. PubMed ID: 15607869 [Abstract] [Full Text] [Related]
20. [Femoral reconstruction with endosteal bone allografts protected by a metallic mesh in reoperation of total hip prosthesis. 19 cases with an average follow-up of 83 months]. Migaud H, Jardin C, Fontaine C, Pierchon F, d'Herbomez O, Duquennoy A. Rev Chir Orthop Reparatrice Appar Mot; 1997 Jan; 83(4):360-7. PubMed ID: 9452810 [Abstract] [Full Text] [Related] Page: [Next] [New Search]