These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
257 related items for PubMed ID: 4048206
1. U.S. Government quality control program for Limulus amebocyte lysate and endotoxin. Hochstein HD. Prog Clin Biol Res; 1985; 189():221-39. PubMed ID: 4048206 [Abstract] [Full Text] [Related]
2. Statistical procedure for standardizing control standard endotoxin against U.S. reference standard endotoxin using Limulus amebocyte lysate test. Rastogi SC. Prog Clin Biol Res; 1982; 93():49-54. PubMed ID: 7122604 [No Abstract] [Full Text] [Related]
3. Guideline for validation of the LAL test as an end-product endotoxin test for human and biological drug products. Munson TE. Prog Clin Biol Res; 1985; 189():211-20. PubMed ID: 4048205 [Abstract] [Full Text] [Related]
4. Collaborative study of a control standard endotoxin using the Limulus amebocyte (gel-clot) test. Adner N, Flink O, Nystrand R, Pihl B, Vegis P. J Parenter Sci Technol; 1991; 45(2):88-93. PubMed ID: 2051262 [Abstract] [Full Text] [Related]
5. The preparation of a control standard endotoxin to be used in both the gel-clot and chromogenic Limulus amebocyte lysate test. Berzofsky RN. Prog Clin Biol Res; 1987; 231():183-8. PubMed ID: 3588616 [No Abstract] [Full Text] [Related]
6. Limulus amebocyte lysate testing of nomral serum albumin (human) in the United States since 1975. Hochstein HD, Seligmann EB, Marquina RE, Rivera E. Dev Biol Stand; 1979; 44():35-42. PubMed ID: 544298 [Abstract] [Full Text] [Related]
7. Review of the Bureau of Biologic's experience with Limulus amebocyte lysate and endotoxin. Hochstein HD. Prog Clin Biol Res; 1982; 93():141-51. PubMed ID: 7122587 [No Abstract] [Full Text] [Related]
8. A modified Limulus amebocyte lysate test with increased sensitivity for detection of bacterial endotoxin. Roth RI, Levin J, Behr S. J Lab Clin Med; 1989 Sep; 114(3):306-11. PubMed ID: 2671216 [Abstract] [Full Text] [Related]
9. Optimization of a chromogenic Limulus amebocyte lysate (LAL) assay for automated endotoxin detection. Bussey DM, Tsuji K. J Parenter Sci Technol; 1984 Sep; 38(6):228-33. PubMed ID: 6527205 [No Abstract] [Full Text] [Related]
10. Comparison of E. coli endotoxin 055:B5 with U.S. Standard Endotoxin EC-5 using the Limulus amebocyte lysate assay. Hochstein HD, Rivera ES, Outschoorn AS. Prog Clin Biol Res; 1987 Sep; 231():133-41. PubMed ID: 3295885 [No Abstract] [Full Text] [Related]
11. Relative potency of "environmental" endotoxin as measured by the Limulus amebocyte lysate test and the USP rabbit pyrogen test. Pearson FC, Weary ME, Bohon J, Dabbah R. Prog Clin Biol Res; 1982 Sep; 93():65-77. PubMed ID: 7122606 [No Abstract] [Full Text] [Related]
12. The effect of refrigeration and mixing on detection of endotoxin in parenteral drugs using the Limulus Amebocyte Lysate (LAL) test. Guilfoyle DE, Yager JF, Carito SL. J Parenter Sci Technol; 1989 Sep; 43(4):183-7. PubMed ID: 2769526 [Abstract] [Full Text] [Related]
14. The use of a quantitative assay in endotoxin testing. Friberger P, Sörskog L, Nilsson K, Knös M. Prog Clin Biol Res; 1987 Sep; 231():149-69. PubMed ID: 3588614 [Abstract] [Full Text] [Related]
15. Chromogenic Limulus amebocyte lysate assay as an aid in the diagnosis of meningitis. Saubolle MA. Prog Clin Biol Res; 1985 Sep; 189():369-85. PubMed ID: 4048214 [Abstract] [Full Text] [Related]
16. Endotoxins and their detection with the Limulus amebocyte lysate test. Proceedings of an International Conference on Endotoxin Standards and Limulus Amebocyte Lysate Use with Parenteral Drugs, Woods Hole, Massachusetts, September 1981. Prog Clin Biol Res; 1982 Sep; 93():1-417. PubMed ID: 7122583 [No Abstract] [Full Text] [Related]
17. Endotoxins and medical devices. Ross VC, Twohy CW. Prog Clin Biol Res; 1985 Sep; 189():267-81. PubMed ID: 4048209 [Abstract] [Full Text] [Related]
18. Plastics, endotoxins, and the Limulus amebocyte lysate test. Roslansky PF, Dawson ME, Novitsky TJ. J Parenter Sci Technol; 1991 Sep; 45(2):83-7. PubMed ID: 2051261 [Abstract] [Full Text] [Related]
19. The bacterial endotoxin test in the PET facility. Williams CC, Borchert RD, Clanton JA. J Nucl Med; 1993 Mar; 34(3):469-73. PubMed ID: 8441042 [Abstract] [Full Text] [Related]
20. Detection of endotoxin in biological products by the limulus test. Cooper JF, Pearson SM. Dev Biol Stand; 1977 Mar; 34():7-13. PubMed ID: 838151 [Abstract] [Full Text] [Related] Page: [Next] [New Search]