These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
155 related items for PubMed ID: 4510852
21. [Moving-filter applied to arc therapy. Studies on conformation radiotherapy. 15. Studies on telecobalt therapy, 26]. Morita K. Nihon Igaku Hoshasen Gakkai Zasshi; 1966 Apr; 26(1):66-77. PubMed ID: 5231510 [No Abstract] [Full Text] [Related]
22. An evaluation of an equation which estimates percentage depth dose for cobalt-60 teletherapy. Schaeflein JW, Neblett DL, Sterling TD, Cember H. Health Phys; 1966 Nov; 12(11):1617-20. PubMed ID: 5971948 [No Abstract] [Full Text] [Related]
23. [Dose computation for telecobalt therapy using a computer]. Leetz HK. Rontgenpraxis; 1969 Nov; 22(11):257-65. PubMed ID: 5367995 [No Abstract] [Full Text] [Related]
24. [Dose distribution within the pelvis using telecobalt moving therapy]. Otake H, Yanagisawa T, Higuchi K, Iida H. Nihon Igaku Hoshasen Gakkai Zasshi; 1969 Apr; 29(1):89-92. PubMed ID: 5255730 [No Abstract] [Full Text] [Related]
25. Intercomparison of absorbed dose in cobalt 60 teletherapy using mailed LiF dosimeters. Pfalzner PM, Malo Alvarez S. Acta Radiol Ther Phys Biol; 1968 Oct; 7(5):379-88. PubMed ID: 5735627 [No Abstract] [Full Text] [Related]
26. The influence of field size, field shape, and source-to-skin distance upon the dose rate in fixed field telecobalt therapy. Anttila P, Spring E. Strahlentherapie; 1968 Feb; 135(2):181-5. PubMed ID: 5670503 [No Abstract] [Full Text] [Related]
27. [The design of aluminium wedge filter for use on cobalt-60 teletherapy]. Urano M, Yamada C, Kikkawa S. Nihon Igaku Hoshasen Gakkai Zasshi; 1966 Jun; 26(3):258-63. PubMed ID: 5231655 [No Abstract] [Full Text] [Related]
28. A computer method for calculating multi-field and rotational dose distributions in Co-60 teletherapy. Jayaraman S. Strahlentherapie; 1970 Sep; 140(3):283-5. PubMed ID: 5509812 [No Abstract] [Full Text] [Related]
29. [On the control of field adjustment by means of exposure with the source of the cobalt therapy unit]. Schuhknecht HJ, Tietze D. Radiobiol Radiother (Berl); 1966 Sep; 7(4):415-20. PubMed ID: 5955438 [No Abstract] [Full Text] [Related]
30. [Telecobalt irradiation of bladder carcinoma with refeence to dose distribution]. Gyenes G. Radiobiol Radiother (Berl); 1969 Sep; 10(6):715-8. PubMed ID: 5379962 [No Abstract] [Full Text] [Related]
31. [Development of a telecobalt therapy unit with a new collimator for conformation radiotherapy. (A study on conformation radiotherapy. 16)]. Kitabatake T, Yamamoto C, Makino S, Nagai K, Takahashi S. Nihon Igaku Hoshasen Gakkai Zasshi; 1966 May; 26(2):192-200. PubMed ID: 5232384 [No Abstract] [Full Text] [Related]
32. [Dosage calculation for conformation radiotherapy applied to cancer of the uterine cervix]. Okumura Y, Mori T, Kitabatake T. Nihon Igaku Hoshasen Gakkai Zasshi; 1967 Nov 25; 27(8):1059-63. PubMed ID: 5245248 [No Abstract] [Full Text] [Related]
33. [Calculation of integral doses in radiotherapy with a cobalt bomb]. Dubinin I, Chvojka Z. Sb Ved Pr Lek Fak Karlovy Univerzity Hradci Kralove; 1969 Nov 25; 12(3):293-301. PubMed ID: 4983369 [No Abstract] [Full Text] [Related]
34. [STUDY OF DOSE TO PROXIMITY OF AIR-TISSUE AND TISSUE-AIR INTERSPACES IN TELECOBALT THERAPY]. LEGARE JM. Acta Radiol Ther Phys Biol; 1964 Apr 25; 2():150-60. PubMed ID: 14162832 [No Abstract] [Full Text] [Related]
35. [Influence of the lung in the distribution of the dose in telecobalt therapy]. da Silva JG. Arq Patol; 1971 Dec 25; 43(3):241-6. PubMed ID: 5154941 [No Abstract] [Full Text] [Related]
36. [Special cones for a telecobalt apparatus and studies on dose distribution in the use of various satellite diaphragms]. Weishaar J, Vogelsang B, Reuss A. Strahlentherapie; 1967 Apr 25; 132(4):504-15. PubMed ID: 4967274 [No Abstract] [Full Text] [Related]
37. The construction of individualised intensity modifying filters in cobalt 60 teletherapy. van de Grijn J. Br J Radiol; 1965 Nov 25; 38(455):865-70. PubMed ID: 5842584 [No Abstract] [Full Text] [Related]
38. [Dose distribution in telecobalt irradiation of collum carcinoma using a central lead filter]. Frischbier HJ, Würthner K. Strahlentherapie; 1972 Sep 25; 144(3):293-306. PubMed ID: 5085137 [No Abstract] [Full Text] [Related]
39. [Evaluation of the therapeutic results of linear x-ray, telecobalt gamma-ray and betatron therapy in internal medicine]. Tsuya A, Kaneta K, Okano S, Goto H, Kamata R. Naika; 1968 Sep 25; 22(3):713-21. PubMed ID: 5708438 [No Abstract] [Full Text] [Related]
40. [Use of wedge filters in telecobalt therapy]. Kuttig H, Herbig W. Strahlentherapie; 1965 Jul 25; 127(3):336-46. PubMed ID: 5841457 [No Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]