These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


130 related items for PubMed ID: 4578115

  • 1. [Measurement of cardiac output using localized thoracic electrical plethysmography (correlation study with the dye dilution technic].
    Demange J, Pernod J, Haguenauer G, Colin J.
    Ann Med Interne (Paris); 1972 Dec; 123(12):1019-24. PubMed ID: 4578115
    [No Abstract] [Full Text] [Related]

  • 2. [Measurement of cardiac output by localized thoracic electrical plethysmography].
    Demange J, Pernod J, Haguenauer G, Colin J.
    Nouv Presse Med; 1972 Dec 16; 1(45):3067-9. PubMed ID: 4567696
    [No Abstract] [Full Text] [Related]

  • 3.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 4.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 5.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 6.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 7. [Non-invasive continuous measurement of the cardiac minute-volume by means of impedance].
    Ritz R, Baitsch G, Burkart F.
    Schweiz Med Wochenschr; 1974 Nov 02; 104(44):1589-90. PubMed ID: 4607503
    [No Abstract] [Full Text] [Related]

  • 8. Development and evaluation of an impedance cardiac output system.
    Kubicek WG, Karnegis JN, Patterson RP, Witsoe DA, Mattson RH.
    Aerosp Med; 1966 Dec 02; 37(12):1208-12. PubMed ID: 5339656
    [No Abstract] [Full Text] [Related]

  • 9. [Comparative evaluation of impedance cardiographic and dye dilution methods in determining hemodynamic indices].
    Kaloianova A.
    Vutr Boles; 1981 Dec 02; 20(4):93-8. PubMed ID: 7029910
    [Abstract] [Full Text] [Related]

  • 10. [Quantitative aortic flow and cardiac output volume determinations in rabbits using tetrapolar impedance plethysmography].
    Schäfer RO, Bruchovetzkij VI, Sutschkov VV.
    Biomed Biochim Acta; 1983 Dec 02; 42(10):1287-97. PubMed ID: 6675670
    [Abstract] [Full Text] [Related]

  • 11. [Comparative study of 2 easy methods for calculation of cardiac output using a dye dilution technic].
    Farhad D, Bardet J, Roudy G, Bourdarias JP, Mathivat A.
    Arch Mal Coeur Vaiss; 1972 Jul 02; 65(7):827-35. PubMed ID: 4633520
    [No Abstract] [Full Text] [Related]

  • 12. Measurement of cardiac output by impedance cardiography in patients with myocardial infarction. Comparative evaluation of impedance and dye dilution methods.
    Gabriel S, Atterhög JH, Orö L, Ekelund LG.
    Scand J Clin Lab Invest; 1976 Jan 02; 36(1):29-34. PubMed ID: 769142
    [Abstract] [Full Text] [Related]

  • 13. [Comparative analysis of cardiac output determined by thermodilution, dye dilution and an impedance method in clinical application].
    Feng JZ.
    Zhonghua Nei Ke Za Zhi; 1982 Sep 02; 21(9):533-5. PubMed ID: 6759072
    [No Abstract] [Full Text] [Related]

  • 14. [Measurement of cardiac output by the dye dilution technic (simplified method of calculation by the so-called initial triangle method)].
    Gay A, Cachin JC, Zappacosta C, Ourbak P, Bourdarias JP, Scebat L.
    Arch Mal Coeur Vaiss; 1967 Dec 02; 60(12):1823-9. PubMed ID: 4969547
    [No Abstract] [Full Text] [Related]

  • 15. A survey of the clinical measurement of cardiac output.
    Kantrowitz P, Kingsley B.
    Med Res Eng; 1971 Dec 02; 10(6):12-9. PubMed ID: 4948525
    [No Abstract] [Full Text] [Related]

  • 16. [Measure of the cardiac output by the dye dilution technic. I. Comparative study with Fick's method].
    Bourdarias JP, Zappacosta C, Ourbak P, Cachin JC, Gay A, Scebat L.
    Rev Fr Etud Clin Biol; 1968 Mar 02; 13(3):299-305. PubMed ID: 4878786
    [No Abstract] [Full Text] [Related]

  • 17. [Measurement of cardiac output by indocyanine green dilution. Comparative clinical study after sampling from the pulmonary artery and the aorta].
    Raffestin B, Merillon JP, Masquet C, Lorente P, Gourgon R.
    Coeur Med Interne; 1975 Mar 02; 14(2):305-10. PubMed ID: 776515
    [No Abstract] [Full Text] [Related]

  • 18. Comparative evaluation of the thoracic impedance and isotope dilution methods for measuring cardiac output.
    Judy WV, Langley FM, McCowen KD, Stinnett DM, Baker LE, Johnson PC.
    Aerosp Med; 1969 May 02; 40(5):532-6. PubMed ID: 4890370
    [No Abstract] [Full Text] [Related]

  • 19. [An exact bloodless method for measuring of the cardiac ouput in man].
    Juchems R, Wertz U.
    Z Kreislaufforsch; 1969 Feb 02; 58(2):215-9. PubMed ID: 4893554
    [No Abstract] [Full Text] [Related]

  • 20. [Measurement of mean circulation time and cardiac volume by earpiece dilution technic--actual calculation method and evaluation of error factors].
    Watanabe T, Genda M, Ishimi Z.
    Naika; 1970 Oct 02; 26(4):706-11. PubMed ID: 4919225
    [No Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 7.