These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. [Pneumatic extracorporeal driving system for a double chamber blood pump (author's transl)]. Wallner F. Langenbecks Arch Chir; 1974 May 02; 335(1):41-6. PubMed ID: 4837034 [No Abstract] [Full Text] [Related]
3. [Historical development of the research project: total heart replacement by artificial blood pumps in Berlin (author's transl)]. Bücherl ES. Langenbecks Arch Chir; 1974 May 02; 335(1):3-11. PubMed ID: 4837032 [No Abstract] [Full Text] [Related]
4. [A short historical outline of the development of extracorporeal circulation and some apparatus artificial "lung-heart" (author's transl)]. Antoszewski Z. Przegl Lek; 1979 May 02; 36(12):869-72. PubMed ID: 397531 [No Abstract] [Full Text] [Related]
5. [The recording-resusci-Anne for training in techniques of cardio-pulmonary resuscitation (author's transl)]. Specht N. Prakt Anaesth; 1974 Jun 02; 9(3):192-6. PubMed ID: 4459911 [No Abstract] [Full Text] [Related]
6. [Development of a circulation mock-up (author's transl)]. Wallner F. Langenbecks Arch Chir; 1974 May 02; 335(1):61-5. PubMed ID: 4837036 [No Abstract] [Full Text] [Related]
7. [Dynamic response of the mock-circulation (author's transl)]. Oh T. Langenbecks Arch Chir; 1974 May 02; 335(1):75-82. PubMed ID: 4837038 [No Abstract] [Full Text] [Related]
8. [Implantation technique in total heart replacement by artificial blood pumps (author's transl)]. Keilbach H, Kleine HO, Götz H, Clevert HD, Krautzberger W, Ruf W, Grosse-Siestrup C, Hennig E, Affeld K, Mohnhaupt A, Mohnhaupt R, Bücherl ES. Langenbecks Arch Chir; 1974 May 02; 335(1):139-55. PubMed ID: 4837040 [No Abstract] [Full Text] [Related]
9. [In vivo experiments for a control system (author's transl)]. Oh T. Langenbecks Arch Chir; 1974 May 02; 335(1):67-74. PubMed ID: 4837037 [No Abstract] [Full Text] [Related]
10. [Automatic regulation of heart synchronically blood circulation pumps]. Thoma H. Biomed Tech (Berl); 1973 Jun 02; 18(3):106-17 concl. PubMed ID: 4740958 [No Abstract] [Full Text] [Related]
11. [Functional replacement of the left heart with an intrathoracally implantable ventricular-aortic blood pump (author's transl)]. Fasching W. Wien Klin Wochenschr Suppl; 1975 Jun 02; 32():3-20. PubMed ID: 1064249 [Abstract] [Full Text] [Related]
12. The permanently implanted bypass heart. Zuhdi N, Ritchie C, Musa N, Carey J, Greer A. J Thorac Cardiovasc Surg; 1965 Dec 02; 50(6):800-10. PubMed ID: 5846182 [No Abstract] [Full Text] [Related]
13. [A self-regulating blood pump for extracorporeal circulation (author's transl)]. Butruille Y, Chevallet J, Granger A, Lissot J, Sausse A. Ann Chir Thorac Cardiovasc; 1977 Jan 02; 16(1):11-5. PubMed ID: 835987 [No Abstract] [Full Text] [Related]
14. [Concerning the question of blood prime of the apparatus for extracorporeal circulation in cardiosurgical operations (author's transl)]. Petri G, GAL G, Kaiser G, Kovács G. Bratisl Lek Listy; 1976 Mar 02; 65(3):271-7. PubMed ID: 181118 [No Abstract] [Full Text] [Related]
15. [Intraocular pressure during operations using the heart-lung machine (author's transl)]. Stellpflug H, Busse H, Niedermeier M, Dittrich H. Klin Monbl Augenheilkd; 1980 Mar 02; 176(3):402-8. PubMed ID: 7421001 [Abstract] [Full Text] [Related]
16. Experience in the development of low haemolysis pumps. Sallam IA, Shaw A, Bain WH. Phys Med Biol; 1976 Mar 02; 21(2):272-9. PubMed ID: 1257305 [Abstract] [Full Text] [Related]
17. Artificial blood-gas interfaces and their application to "membrane oxygenators." Author's oxygenator module represents closest approximation to natural lung yet devised. Galletti PM. R I Med J; 1970 Sep 02; 53(9):503-5 passim. PubMed ID: 5272952 [No Abstract] [Full Text] [Related]
18. [Present status and future problems on the research and development of artificial heart (author's transl)]. Atsumi K. Nihon Kyobu Geka Gakkai Zasshi; 1975 Apr 02; 23(4):372-7. PubMed ID: 1170257 [No Abstract] [Full Text] [Related]
19. [Studies on changes in blood coagulation during and after operations with the help of the heart lung machine (author's transl)]. Köstering H, Kirchhoff PG, Völker P, Warmann E, Koncz J. Thoraxchir Vask Chir; 1973 Dec 02; 21(6):534-43. PubMed ID: 4544868 [No Abstract] [Full Text] [Related]
20. [Regulation problems in circulation relieving pumps]. Schaldach M, Dittrich H. Thoraxchir Vask Chir; 1970 Oct 02; 18(5):370-6. PubMed ID: 5275529 [No Abstract] [Full Text] [Related] Page: [Next] [New Search]