These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
75 related items for PubMed ID: 4864848
1. Measurement of stroke volume by the vibrocardiogram. Agress CM, Wegner S, Fremont RP, Mori I, Day DJ. Aerosp Med; 1967 Dec; 38(12):1248-52. PubMed ID: 4864848 [No Abstract] [Full Text] [Related]
2. [Cardiodynamic findings during muscular activity in cases of myocardial infarct]. Strozzi C. Policlinico Med; 1968 Dec; 75(6):339-56. PubMed ID: 5733999 [No Abstract] [Full Text] [Related]
3. [Heart rate at the working site and physical capacity in heart infarct patients and normal persons]. Weidemann H, Kluxen M, Roskamm H, Reindell H, Nöcker J. Med Klin; 1970 Apr 24; 65(17):828-35. PubMed ID: 5519241 [No Abstract] [Full Text] [Related]
4. [Interpretation of the kinetocardiogram of the right heart]. Degtiarev VA, Kormer AIa, Rogov VA, Tolpekin VE, Tsyganov LP. Kosm Biol Aviakosm Med; 1986 Apr 24; 20(3):69-71. PubMed ID: 3525981 [Abstract] [Full Text] [Related]
5. [On the effect of moderate blood loss on the cardiac output, stroke volume and the whole peripheral resistance]. Juchems R, Ammerschläger G. Z Kreislaufforsch; 1967 Oct 24; 56(10):963-72. PubMed ID: 4873963 [No Abstract] [Full Text] [Related]
6. Measurement of cardiac output by impedance cardiography in patients with myocardial infarction. Comparative evaluation of impedance and dye dilution methods. Gabriel S, Atterhög JH, Orö L, Ekelund LG. Scand J Clin Lab Invest; 1976 Jan 24; 36(1):29-34. PubMed ID: 769142 [Abstract] [Full Text] [Related]
7. [The measuring of the amount of cardiac output as a monitor (author's transl)]. Hamano A. Masui; 1978 Jan 24; 27(1):21-30. PubMed ID: 344926 [No Abstract] [Full Text] [Related]
9. [Determination of the indicators of stroke volume by the methods of dye dilution and echocardiography in mycardial infarct]. Golyshnikov VA, Kutsenko AI. Kardiologiia; 1976 Jun 24; 16(6):101-4. PubMed ID: 799182 [Abstract] [Full Text] [Related]
10. [Relaibility of the cardiac output determination by the method of dye dilution curves]. Ambrosioni E, Altilia F, Bracchetti D. G Clin Med; 1967 Jan 24; 48(1):49-65. PubMed ID: 4883269 [No Abstract] [Full Text] [Related]
11. Earpiece dye dilution technique as a method for evaluation of haemodynamic changes during standardized effort test. Zochowski RJ, Serzysko W. Cor Vasa; 1971 Jan 24; 13(1):50-63. PubMed ID: 4935543 [No Abstract] [Full Text] [Related]
12. [Left ventricular performance in sequelae of myocardial infarct without manifest ventricular insufficiency--evaluation by multiple non-invasive methods]. Gherasim L, Cinteză M, Mihăileanu S, Pop T, Toporan M, Petcu E, Pirvu V. Rev Med Interna Neurol Psihiatr Neurochir Dermatovenerol Med Interna; 1980 Jan 24; 32(5):417-32. PubMed ID: 6113660 [No Abstract] [Full Text] [Related]
14. [Stroke volume and human cardiac output in random contraction rhythm]. Izakov VIa, Antiuf'ev VF. Fiziol Cheloveka; 1984 Jan 24; 10(4):631-9. PubMed ID: 6530103 [No Abstract] [Full Text] [Related]
15. [Hemodynamic findings in patients with myocardial infarct in the acute stage and at the end of hospitalization (with special reference to stress capacity of the infarct-injured heart)]. Lönne E, Weidemann H, Herkel L, Schnellbacher K, Scholz H, Möller K, Baumeister L, Roskamm H, Pabst K. Verh Dtsch Ges Kreislaufforsch; 1971 Jan 24; 37():187-91. PubMed ID: 4946595 [No Abstract] [Full Text] [Related]
16. [Measurement of cardiac output by the dye dilution technic (simplified method of calculation by the so-called initial triangle method)]. Gay A, Cachin JC, Zappacosta C, Ourbak P, Bourdarias JP, Scebat L. Arch Mal Coeur Vaiss; 1967 Dec 24; 60(12):1823-9. PubMed ID: 4969547 [No Abstract] [Full Text] [Related]
17. Hemodynamic observations during closed-chest cardiac massage. Oriol A, Smith HJ. Can Med Assoc J; 1968 May 04; 98(18):841-3. PubMed ID: 4869681 [No Abstract] [Full Text] [Related]
18. Hemodynamics of acute myocardial infarction. Comparison of "uncomplicated" and mild left ventricular failure. Goulden DD, Friesinger GC, Hodges M. Johns Hopkins Med J; 1972 Oct 04; 131(4):271-80. PubMed ID: 5081729 [No Abstract] [Full Text] [Related]
19. Comparison of stroke volume and cardiac output determination by ultrasound and dye dilution in acute myocardial infarction. Pombo JF, Russell RO, Rackley CE, Foster GL. Am J Cardiol; 1971 Jun 04; 27(6):630-5. PubMed ID: 4932616 [No Abstract] [Full Text] [Related]
20. [Comparative evaluation of the radiocardiographic and the dye dilution methods of determining cardiac output and circulating blood volume]. Beloev I, Sheĭretova E, Kaloianova A. Vutr Boles; 1980 Jun 04; 19(1):40-4. PubMed ID: 6989114 [Abstract] [Full Text] [Related] Page: [Next] [New Search]