These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
121 related items for PubMed ID: 4885292
21. [Simple method for quantitative description of the stroke volume-central pool ratio]. Klempt HW, Noder W. Z Kreislaufforsch; 1969 Oct; 58(10):1101-9. PubMed ID: 4917677 [No Abstract] [Full Text] [Related]
22. Tracer dilution curves in cardiology and random walk and lognormal distributions. Wise ME. Acta Physiol Pharmacol Neerl; 1966 Oct; 14(2):175-204. PubMed ID: 5336541 [No Abstract] [Full Text] [Related]
23. [Comparative evaluation of the radiocardiographic and the dye dilution methods of determining cardiac output and circulating blood volume]. Beloev I, Sheĭretova E, Kaloianova A. Vutr Boles; 1980 Oct; 19(1):40-4. PubMed ID: 6989114 [Abstract] [Full Text] [Related]
24. [A simple method for estimation of the cardiac output]. Noder W. Z Kreislaufforsch; 1970 Mar; 59(3):226-35. PubMed ID: 4919931 [No Abstract] [Full Text] [Related]
25. [Measurement of cardiac output using localized thoracic electrical plethysmography (correlation study with the dye dilution technic]. Demange J, Pernod J, Haguenauer G, Colin J. Ann Med Interne (Paris); 1972 Dec; 123(12):1019-24. PubMed ID: 4578115 [No Abstract] [Full Text] [Related]
26. [Determination of the cardiac output by the dye dilution technic: comparison between the conventional Stewart-Hamilton method, the simplified initial triangle method and Fick's methods]. Innocenti P, Toso M, Buoncristiani U, Alicandri C, Todisco T, Marchesi N. Folia Cardiol; 1968 Dec; 27(6):354-62. PubMed ID: 4898136 [No Abstract] [Full Text] [Related]
27. [The determination of cardiac minute volume by quantitative evaluation of ascorbate dilution curves]. Grabner G, Paumgartner G, Pokorny D. Wien Z Inn Med; 1965 Sep; 46(9):351-7. PubMed ID: 5328463 [No Abstract] [Full Text] [Related]
28. Determination of the cardiac output of anaesthetised pigs using a dye dilution method. Lucke JN. Res Vet Sci; 1976 Nov; 21(3):364-5. PubMed ID: 799827 [Abstract] [Full Text] [Related]
29. [Analysis of empyrical factors for the determination of cardiac output]. Herrera EL, Terwes E, Song Sang YP, Prefant C, Anthonisen NR. Arch Inst Cardiol Mex; 1978 Nov; 48(3):483-500. PubMed ID: 697453 [Abstract] [Full Text] [Related]
30. [Results with the dye dilution technic for the answering of clinical physiological questions]. Schneider KW. Z Gesamte Inn Med; 1969 Jan 15; 24(2):33-44. PubMed ID: 4894057 [No Abstract] [Full Text] [Related]
32. [Determination of the cardiac output by the dye dilution method using oximeter and continuous recording in comparison to Fick principle]. Ansari MA, Porstmann W, Günther KH, Wierny L. Dtsch Gesundheitsw; 1966 Jan 27; 21(4):176-82. PubMed ID: 5328962 [No Abstract] [Full Text] [Related]
33. Cardiac output determination: superiority of thermal dilution. Solomon HA, San Marco MA, Ellis RJ, Lillehei CW. Surg Forum; 1969 Jan 27; 20():28-30. PubMed ID: 4910599 [No Abstract] [Full Text] [Related]
34. [Determination of the heart-minute volume by means of dye dilution]. Günther KH, Strangfeld D, Ansari MA. Z Gesamte Inn Med; 1966 Jun 01; 21(11):Suppl:128. PubMed ID: 4869838 [No Abstract] [Full Text] [Related]
35. [Calculation of cardiac output by computer and planimetry. Comparison of results]. Diez Balda V, de la Serna JL, Rubio JJ, Galdoś Anuncibay P, Tomás Fanjul MI, Domińguez de Villota E, Mosquera Gonzalez JM. Rev Clin Esp; 1982 Apr 15; 165(1):31-4. PubMed ID: 6750706 [No Abstract] [Full Text] [Related]
36. [Dye dilution curves. II. Application to measurement of cardiac output]. Bourdarias JP, Ourbak P, Scebat L, Lenègre J. Coeur Med Interne; 1968 Jan 15; 7(1):133-48. PubMed ID: 4910265 [No Abstract] [Full Text] [Related]
37. [Use of Dow's formula for calculation of the volume of cardiac output by dye dilution curves]. Gratsianskiĭ NA. Kardiologiia; 1973 Oct 15; 13(10):119-20. PubMed ID: 4592665 [No Abstract] [Full Text] [Related]
38. Comparison of the determination of cardiac output by the dye dilution method and electromagnetic flowmetry. Brunsting JR, Bredée JJ, Eygelaar A, ten Hoor F, Visser KR. Pflugers Arch; 1970 Oct 15; 314(2):147-8. PubMed ID: 4903731 [No Abstract] [Full Text] [Related]
39. [Selection of a rational method of calculation of minute blood volume by the dye dilution curves]. Zhdanov VF, Akaeva TSh. Kardiologiia; 1975 Jun 15; 15(6):110-13. PubMed ID: 1102752 [Abstract] [Full Text] [Related]
40. Accuracy of calibration of electromagnetic flow-probe by dye dilution method. Min BG, Fich S, Shiang HS. Bull N Y Acad Med; 1977 Nov 15; 53(9):829-40. PubMed ID: 144539 [No Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]