These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
135 related items for PubMed ID: 4937815
1. A new inexpensive IPPV exhalation valve for automatic ventilators. Eross B. Anesthesiology; 1971 Sep; 35(3):317-9. PubMed ID: 4937815 [No Abstract] [Full Text] [Related]
2. A simple safety valve for infant resuscitator and ventilator gas circuits. Goddard PJ, Becket AJ. Lancet; 1971 Sep 11; 2(7724):584. PubMed ID: 4106110 [No Abstract] [Full Text] [Related]
3. An inexpensive continuous positive end-expiratory pressure (PEEP) adaptor for positive pressure respirators. Woods R, Rogers RM, Sugerman HJ, Tantum KR. Chest; 1972 Apr 11; 61(4):376-8. PubMed ID: 4553501 [No Abstract] [Full Text] [Related]
4. [Adaptation of the Chirolog 3 ventilator breathing system to intermittent artificial pulmonary respiration and its variants of spontaneous breathing with continuous pressure]. Pachl J, Zábrodský V, Pokorný J. Rozhl Chir; 1979 Nov 11; 58(11):701-5. PubMed ID: 394358 [No Abstract] [Full Text] [Related]
6. Apparatus for the administration of Entonox (50 percent N20: 50 percent O2 mixture) by intermittent positive pressure. The modified MinEpac ventilator and the Mini Resuscitator ventilation. Nancekievill D. Anaesthesia; 1974 Nov 11; 29(6):736-9. PubMed ID: 4611268 [No Abstract] [Full Text] [Related]
7. Noninvasive positive pressure ventilation. Equipment and techniques. Drinkwine J, Kacmarek RM. Respir Care Clin N Am; 1996 Jun 11; 2(2):183-94. PubMed ID: 9390878 [Abstract] [Full Text] [Related]
8. Respiratory therapy in the neonatal intensive care unit. Wimmer JE, Parsons DG. Clin Perinatol; 1976 Sep 11; 3(2):379-90. PubMed ID: 786525 [No Abstract] [Full Text] [Related]
9. A new piston ventilator for use in respiratory studies. Volgyesi GA, Nisbet HI. Can Anaesth Soc J; 1972 Nov 11; 19(6):662-9. PubMed ID: 4564460 [No Abstract] [Full Text] [Related]
10. Mechanical ventilators. Grogono AW. Int Anesthesiol Clin; 1966 Nov 11; 4(3):497-532. PubMed ID: 5335339 [No Abstract] [Full Text] [Related]
11. Monitoring of noninvasive ventilation by built-in software of home bilevel ventilators: a bench study. Contal O, Vignaux L, Combescure C, Pepin JL, Jolliet P, Janssens JP. Chest; 2012 Feb 11; 141(2):469-476. PubMed ID: 21778253 [Abstract] [Full Text] [Related]
12. Mechanical failure of a ventilator: a case report. Arkinstall WW, Epstein SW. Anesth Analg; 1973 Feb 11; 52(1):48-52. PubMed ID: 4567518 [No Abstract] [Full Text] [Related]
13. AN EXPIRATORY VALVE FOR USE WITH POSITIVE PRESSURE VENTILATORS IN INFANTS. SELLERS RD, LEVY MJ, LILLEHEI CW. J Thorac Cardiovasc Surg; 1964 May 11; 47():616-9. PubMed ID: 14159053 [No Abstract] [Full Text] [Related]
14. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation. DiBlasi RM, Salyer JW, Zignego JC, Redding GJ, Richardson CP. Respir Care; 2008 Nov 11; 53(11):1450-60. PubMed ID: 18957147 [Abstract] [Full Text] [Related]
15. [A new respiration monitor]. Stoeckel H. Z Prakt Anasth; 1971 Aug 11; 6(4):282-5. PubMed ID: 4259554 [No Abstract] [Full Text] [Related]
16. Influence of exhalation valve and nebulizer position on albuterol delivery during noninvasive positive pressure ventilation. Dai B, Kang J, Sun LF, Tan W, Zhao HW. J Aerosol Med Pulm Drug Deliv; 2014 Apr 11; 27(2):125-32. PubMed ID: 23668546 [Abstract] [Full Text] [Related]
17. [Quantitative comparison of ventilator-induced work during simulated CPAP in eight demand-flow valve ventilators]. Nishimura M, Imanaka H, Taenaka N, Yoshiya I, Takezawa J. Masui; 1989 Aug 11; 38(8):1017-29. PubMed ID: 2681861 [Abstract] [Full Text] [Related]
18. The bird respirator modified for PEEP, CPAP and IMV. Torda TA, Roderick C. Anaesth Intensive Care; 1978 May 11; 6(2):149-54. PubMed ID: 352194 [Abstract] [Full Text] [Related]