These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


136 related items for PubMed ID: 524436

  • 21.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 22.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 23. Detection of red cell antibodies: comparison of two low ionic strength diluents.
    Skaik YA, Overfield J.
    Br J Biomed Sci; 2006; 63(1):18-20. PubMed ID: 16613136
    [Abstract] [Full Text] [Related]

  • 24. Weak "false positive" direct antiglobulin test reactions with polyspecific antiglobulin reagents: lack of correlation with red-blood-cell-bound C3d.
    Nasongkla M, Hummert J, Chaplin H.
    Transfusion; 1982; 22(4):273-5. PubMed ID: 6980507
    [Abstract] [Full Text] [Related]

  • 25. Pretransfusion blood group serology. Limited value of the antiglobulin phase of the crossmatch when a careful screening test for unexpected antibodies is performed.
    Heistø H.
    Transfusion; 1979; 19(6):761-3. PubMed ID: 118557
    [Abstract] [Full Text] [Related]

  • 26. [Quality control in immuno-hematology tests: evaluation and prospects].
    Rouger P, Salmon C.
    Rev Fr Transfus Immunohematol; 1984 Apr; 27(2):141-53. PubMed ID: 6431588
    [No Abstract] [Full Text] [Related]

  • 27. Red cell antibody screening with the Groupamatic system. I. Bromelin methyl-cellulose and saline techniques: evaluation of five years' routine use.
    Garretta M, Gener J, de Jerphanion I, Jacquet D, Muller A.
    Vox Sang; 1979 Apr; 37(1):55-61. PubMed ID: 115156
    [Abstract] [Full Text] [Related]

  • 28.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 29.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 30. A proposal for compatibility testing incorporating the manual hexadimethrine bromide (Polybrene) test.
    Steane EA, Steane SM, Montgomery SR, Pearson JR.
    Transfusion; 1985 Apr; 25(6):540-4. PubMed ID: 4071598
    [Abstract] [Full Text] [Related]

  • 31. Problems highlighted when using anticoagulated samples in the standard tube low ionic strength antiglobulin test.
    Sweeney AJ.
    Immunohematology; 2006 Apr; 22(2):72-7. PubMed ID: 16813469
    [Abstract] [Full Text] [Related]

  • 32. Paper-based assay for red blood cell antigen typing by the indirect antiglobulin test.
    Yeow N, McLiesh H, Guan L, Shen W, Garnier G.
    Anal Bioanal Chem; 2016 Jul; 408(19):5231-8. PubMed ID: 27185543
    [Abstract] [Full Text] [Related]

  • 33. Selection of procedures for compatibility testing of blood.
    Farr AD.
    Med Lab Sci; 1980 Mar; 37(2):105-6. PubMed ID: 6995773
    [No Abstract] [Full Text] [Related]

  • 34.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 35.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 36.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 37. The UK National External Quality Assessment Scheme in Blood Group Serology. Compatibility testing 1983-1984: the influence of variables in test procedures on detection of incomplete antibodies.
    Holburn AM, Prior D.
    Clin Lab Haematol; 1987 Mar; 9(1):33-48. PubMed ID: 3581715
    [Abstract] [Full Text] [Related]

  • 38.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 39.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 40. Two-stage papain-indirect antiglobulin test and LISS direct agglutination are not appropriate for pretransfusion screening for unexpected antibodies.
    Pereira A, Mazzara R, Gelabert A, Castillo R.
    Haematologica; 1991 Mar; 76(6):475-8. PubMed ID: 1820984
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 7.