These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
253 related items for PubMed ID: 5999313
1. [Replacement of the aortic and mitral valves by using the Starr-Edwards ball valve prothesis]. Kalagan DS. Khirurgiia (Mosk); 1966 Oct; 42(10):13-8. PubMed ID: 5999313 [No Abstract] [Full Text] [Related]
6. [Artificial heart valves and intravascular hemolysis]. Mezger J, Weinhold C, Kreuzer E, Erdmann E. Internist (Berl); 1988 Nov; 29(11):781-3. PubMed ID: 3069791 [No Abstract] [Full Text] [Related]
7. Intravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis. Falk RH, Mackinnon J, Wainscoat J, Melikian V, Bignell AH. Thorax; 1979 Dec; 34(6):746-8. PubMed ID: 542913 [Abstract] [Full Text] [Related]
8. Dynamic block of disc valve - blocking of aortic disc prosthesis due to protrusion of mitral prosthesis into the left ventricular outflow tract. Li R, Ni Y, Feng Q, Luo W. Thorac Cardiovasc Surg; 2007 Oct; 55(7):469-70. PubMed ID: 17902076 [Abstract] [Full Text] [Related]
9. Mitral valve repair versus replacement in simultaneous mitral and aortic valve surgery for rheumatic disease. Kuwaki K, Kawaharada N, Morishita K, Koyanagi T, Osawa H, Maeda T, Higami T. Ann Thorac Surg; 2007 Feb; 83(2):558-63. PubMed ID: 17257987 [Abstract] [Full Text] [Related]
11. Incidence of thromboembolic complications using totally cloth-covered Starr-Edwards prostheses. Vidne B, Levy MJ. Isr J Med Sci; 1974 Jun; 10(6):586-9. PubMed ID: 4852393 [No Abstract] [Full Text] [Related]
12. [Mitral valve substitution with the Starr-Edwards prosthesis. Results in 76 cases]. Benavides PH, Correa R, Corona E. Arch Inst Cardiol Mex; 1966 Jun; 36(3):255-63. PubMed ID: 5913226 [No Abstract] [Full Text] [Related]
13. Extended (31 years) durability of a Starr-Edwards prosthesis in mitral position. Tarzia V, Bottio T, Testolin L, Gerosa G. Interact Cardiovasc Thorac Surg; 2007 Aug; 6(4):570-1. PubMed ID: 17669941 [Abstract] [Full Text] [Related]
14. Patient with a Starr-Edwards prosthesis in the aortic position for 40 years. Miranda M, do Nascimento L, Haddad MR, Haddad WT, Haddad WT, Buffolo E. J Heart Valve Dis; 2013 Sep; 22(5):648-50. PubMed ID: 24383375 [Abstract] [Full Text] [Related]
15. Mechanical valves: a comparative analysis of the Starr-Edwards and Björk-Shiley prostheses. Murphy DA, Levine FH, Buckley MJ, Swinski L, Daggett WM, Akins CW, Austen WG. J Thorac Cardiovasc Surg; 1983 Nov; 86(5):746-52. PubMed ID: 6632948 [Abstract] [Full Text] [Related]
16. Aortic and mitral valve replacement in children: is there any role for biologic and bioprosthetic substitutes? Alsoufi B, Manlhiot C, McCrindle BW, Canver CC, Sallehuddin A, Al-Oufi S, Joufan M, Al-Halees Z. Eur J Cardiothorac Surg; 2009 Jul; 36(1):84-90; discussion 90. PubMed ID: 19369085 [Abstract] [Full Text] [Related]