These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


128 related items for PubMed ID: 6194228

  • 1. An enzyme-linked immunoassay for circulating immune complexes using solid phased goat Clq.
    Lin TM, Halbert SP, Cort R, Blaschke MJ.
    J Immunol Methods; 1983 Oct 14; 63(2):187-205. PubMed ID: 6194228
    [Abstract] [Full Text] [Related]

  • 2. The detection of circulating immune complexes containing C1q and IgG using a new rapid serum ELISA test system.
    Reckel RP, Harris J, Botsko E, Wellerson R, Varga S.
    Diagn Immunol; 1984 Oct 14; 2(4):228-37. PubMed ID: 6335421
    [Abstract] [Full Text] [Related]

  • 3. An enzyme-linked immunoassay for detection of IgG- and C3-containing circulating immune complexes: comparison with a radioimmunoassay and quantitation in patients with rheumatic diseases.
    Panush RS, Somberg LB, Katz P, Longley S.
    Diagn Immunol; 1983 Oct 14; 1(4):288-94. PubMed ID: 6388973
    [Abstract] [Full Text] [Related]

  • 4. Detection of C1q-bearing immune complexes by a monoclonal anti-C1q ELISA system.
    Antes U, Heinz HP, Loos M.
    J Immunol Methods; 1987 Sep 24; 102(2):149-56. PubMed ID: 2443573
    [Abstract] [Full Text] [Related]

  • 5. [Use of solid-phase Clq-ELISA for detecting circulating immune complexes in human diseases].
    Aleshkin VA, Nasonov EL, Eremeeva MV, Kobylianskiĭ AG.
    Ter Arkh; 1989 Sep 24; 61(6):113-6. PubMed ID: 2477907
    [Abstract] [Full Text] [Related]

  • 6. [Demonstration of circulating immune complexes using a C1q-solid phase enzyme immunoassay].
    Schössler W, Hiepe F, Courault K, Porstmann B, Apostoloff E.
    Biomed Biochim Acta; 1983 Sep 24; 42(7-8):1027-35. PubMed ID: 6360166
    [Abstract] [Full Text] [Related]

  • 7. Solid-phase Clq-binding fluorescence immunoassay for detection of circulating immune complexes.
    Collins MM, Casavant CH, Stites DP.
    J Clin Microbiol; 1982 Mar 24; 15(3):456-64. PubMed ID: 6804486
    [Abstract] [Full Text] [Related]

  • 8. Statistical analysis of five immune complex screening assays: patterns of detection in patients with rheumatoid arthritis, systemic lupus erythematosus, infectious endocarditis, and diabetes mellitus.
    Kilpatrick JM, Virella G.
    Diagn Immunol; 1983 Mar 24; 1(2):57-63. PubMed ID: 6388965
    [Abstract] [Full Text] [Related]

  • 9. [Determination of circulating immune complexes and of their component immunoglobulin classes M, G, and A with a C1q-ELISA].
    Sequeira Peña GA, Herrmann D, Vogt KH, Jäger L.
    Allerg Immunol (Leipz); 1991 Mar 24; 37(1):37-45. PubMed ID: 2063729
    [Abstract] [Full Text] [Related]

  • 10. Serum and plasma fibronectin binds to complement reacted immune complexes primarily via Clq.
    Baatrup G, Svehag SE.
    Scand J Immunol; 1986 Nov 24; 24(5):583-90. PubMed ID: 3097811
    [Abstract] [Full Text] [Related]

  • 11. Investigation of the recommended use of anti-Clq for reducing non-specific reactions in solid-phase C1q assays for circulating immune complexes.
    Wainer EM, Schepers G, Schweizer K, Pusztai-Markos Z.
    J Immunol Methods; 1984 Jan 20; 66(1):193-5. PubMed ID: 6363550
    [No Abstract] [Full Text] [Related]

  • 12. Measurement of circulating immune complexes in human sera by enzyme immunoassay.
    Cheung K, O'Kane D, Robinson MF.
    Aust J Exp Biol Med Sci; 1982 Dec 20; 60(6):593-605. PubMed ID: 6820632
    [Abstract] [Full Text] [Related]

  • 13. Characterization of the soluble immune complexes that are detected by three different techniques.
    van der Giessen M, The TH.
    Clin Immunol Immunopathol; 1986 Feb 20; 38(2):244-55. PubMed ID: 3484441
    [Abstract] [Full Text] [Related]

  • 14. A solid phase C1q enzyme assay for circulating immune complexes adapted for routine clinical laboratory testing.
    James K, Vahey A, Robinson M, Marder R.
    Am J Clin Pathol; 1983 Oct 20; 80(4):445-52. PubMed ID: 6353904
    [Abstract] [Full Text] [Related]

  • 15. [Determination of circulating immune complexes in hematological diseases by Clq ELISA (a microplate method)].
    Hayashi S, Oshida M, Tsubakio T, Kurata Y.
    Rinsho Byori; 1983 Jun 20; 31(6):621-4. PubMed ID: 6361331
    [No Abstract] [Full Text] [Related]

  • 16. The use of solid phase Clq and horseradish peroxidase-conjugated goat anti-IgG for the detection of immune complexes in human serum.
    Wehler C, Andrews JM, Bing DH.
    Mol Immunol; 1981 Mar 20; 18(3):157-62. PubMed ID: 6973690
    [No Abstract] [Full Text] [Related]

  • 17. Circulating immune complexes and rheumatoid arthritis.
    Faaber P, Rijke Schilder TP, Capel PJ, Koene RA.
    J Rheumatol; 1985 Oct 20; 12(5):849-53. PubMed ID: 3878875
    [Abstract] [Full Text] [Related]

  • 18. A Clq solid phase microenzymatic assay for the detection of soluble immune complexes.
    Cordiali Fei P, Natali PG.
    Ric Clin Lab; 1981 Oct 20; 11(3):207-14. PubMed ID: 6974886
    [Abstract] [Full Text] [Related]

  • 19. Evaluation of six tests for circulating IgG complexes with special reference to IgM rheumatoid factors: analysis of systemic lupus erythematosus and rheumatoid arthritis series.
    Wager O, Lindström P, Räsänen JA, Kekomäki R, Ziola B, Salmi A, Isomäki H, Skrifvars B, Penttinen K.
    Clin Exp Immunol; 1981 Oct 20; 46(1):149-60. PubMed ID: 7337967
    [Abstract] [Full Text] [Related]

  • 20. Circulating immune complex-like materials which bind to heat inactivated C1q interfere with the C1q solid phase assay for immune complexes.
    Fukuda K, Seino J, Kinoshita Y, Sudo K, Horigome I, Saito T, Furuyama T, Yoshinaga K.
    Tohoku J Exp Med; 1985 Aug 20; 146(4):449-56. PubMed ID: 3907015
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 7.