These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
103 related items for PubMed ID: 6338985
1. The isotope clearance technique for measuring skin blood flow. Young CM, Hopewell JW. Br J Plast Surg; 1983 Apr; 36(2):222-30. PubMed ID: 6338985 [Abstract] [Full Text] [Related]
2. Observations on dermal blood flow as reflected by technetium-99m pertechnetate clearance. Waterhouse N, Finney R, Griffiths RW, Richardson RB. Br J Plast Surg; 1986 Jul; 39(3):312-20. PubMed ID: 3015309 [Abstract] [Full Text] [Related]
3. The evaluation of an isotope clearance technique in the dermis of pig skin: a correlation of functional and morphological parameters. Young CM, Hopewell JW. Microvasc Res; 1980 Sep; 20(2):182-94. PubMed ID: 7432192 [No Abstract] [Full Text] [Related]
4. The effects of preoperative x-irradiation on the survival and blood flow of pedicle skin flaps in the pig. Young CM, Hopewell JW. Int J Radiat Oncol Biol Phys; 1983 Jun; 9(6):865-70. PubMed ID: 6863060 [Abstract] [Full Text] [Related]
5. The revascularization of pedicle skin flaps in pigs: a functional and morphologic study. Young CM. Plast Reconstr Surg; 1982 Oct; 70(4):455-64. PubMed ID: 6287512 [Abstract] [Full Text] [Related]
6. The evaluation of an isotopic clearance technique for the measurement of skin blood flow in the pig. Moustafa HF, Hopewell JW. Microvasc Res; 1976 Mar; 11(2):147-53. PubMed ID: 775255 [No Abstract] [Full Text] [Related]
7. The measurement of blood flow in pig skin after single or fractionated doses of x-irradiation. Young CM, Hopewell JW. Bibl Anat; 1977 Mar; (15 Pt 1):326-30. PubMed ID: 339901 [No Abstract] [Full Text] [Related]
8. Circulation of pedicle flaps studied by tissue clearance of 99mTc-pertechnetate. Schnur P, Simons JN, Tauxe WN. Surg Forum; 1969 Mar; 20():513-4. PubMed ID: 4910625 [No Abstract] [Full Text] [Related]
9. Technetium-99m pertechnetate disappearance studies in normal and psoriatic skin. DiLorenzo PA, Brown DW, Walker SH, Dern PL, Goltz RW. J Invest Dermatol; 1971 Jan; 56(1):39-43. PubMed ID: 4933756 [No Abstract] [Full Text] [Related]
10. Timing of distant flap pedicle division using xenon 133 clearance. Snelling CF, Poomee A, Sutherland JB, Waters WR, Wangsanutr L, Mackereth E. Ann Plast Surg; 1980 Sep; 5(3):205-11. PubMed ID: 7447289 [Abstract] [Full Text] [Related]
11. Hydrogen clearance: assessment of technique for measurement of skin-flap blood flow in pigs. Thomson JG, Kerrigan CL. Plast Reconstr Surg; 1991 Oct; 88(4):657-63. PubMed ID: 1896537 [Abstract] [Full Text] [Related]
12. Blood flow clearance changes in pig skin after single doses of X rays. Moustafa HF, Hopewell JW. Br J Radiol; 1979 Feb; 52(614):138-44. PubMed ID: 427365 [Abstract] [Full Text] [Related]
13. Measurement of skin and total blood flow to the rabbit lower limb by washout of freely diffusible radioactive tracers introduced intra-arterially. Adiseshiah M, Barber RW, Ritson A, Szaz KF. Eur Surg Res; 1984 Feb; 16(6):372-7. PubMed ID: 6394343 [Abstract] [Full Text] [Related]
14. Measurement of blood flow in skin with an intact vascular pedicle. Marcus FS, Cho SI, Kountz SL, Powell MR. Int J Dermatol; 1976 Mar; 15(2):131-5. PubMed ID: 1254385 [Abstract] [Full Text] [Related]
15. Hemodynamics and vascular sensitivity to circulating norepinephrine in normal skin and delayed and acute random skin flaps in the pig. Pang CY, Neligan PC, Forrest CR, Nakatsuka T, Sasaki GH. Plast Reconstr Surg; 1986 Jul; 78(1):75-84. PubMed ID: 3725957 [Abstract] [Full Text] [Related]
16. Augmentation of blood flow in delayed random skin flaps in the pig: effect of length of delay period and angiogenesis. Pang CY, Forrest CR, Neligan PC, Lindsay WK. Plast Reconstr Surg; 1986 Jul; 78(1):68-74. PubMed ID: 2425389 [Abstract] [Full Text] [Related]
17. On expander pressure and skin blood flow during tissue expansion in the pig. Min Z, Svensson H, Svedman P. Ann Plast Surg; 1988 Aug; 21(2):134-9. PubMed ID: 3178120 [Abstract] [Full Text] [Related]
18. [Measurement of renal circulation using isotope dilution technique after selective arterial injection of 99m-Tc-pertechnetate (author's transl)]. Oberdorfer M, Heidenreich P. Rofo; 1975 Mar; 122(3):251-6. PubMed ID: 124686 [Abstract] [Full Text] [Related]
19. The measurement of skin lymph flow by isotope clearance--reliability, reproducibility, injection dynamics, and the effect of massage. Mortimer PS, Simmonds R, Rezvani M, Robbins M, Hopewell JW, Ryan TJ. J Invest Dermatol; 1990 Dec; 95(6):677-82. PubMed ID: 2250109 [Abstract] [Full Text] [Related]
20. Decreased blood flow in a papaverine-induced passive vascular bed in sclerodermal skin. Kristensen JK, Henriksen O. Acta Derm Venereol; 1979 Dec; 59(2):145-7. PubMed ID: 84492 [Abstract] [Full Text] [Related] Page: [Next] [New Search]