These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
6. Measurement of glycosylated amino acids and peptides from urine of diabetic patients using affinity chromatography. Brownlee M, Vlassara H, Cerami A. Diabetes; 1980 Dec; 29(12):1044-7. PubMed ID: 6777222 [Abstract] [Full Text] [Related]
7. Demonstration of a minor hemoglobin with modified alpha chains and additional modified hemoglobins in normal and diabetic adults. Abraham EC, Stallings M, Abraham A, Clardy R. Biochim Biophys Acta; 1983 May 18; 744(3):335-41. PubMed ID: 6849935 [Abstract] [Full Text] [Related]
8. Effects of whole blood storage on results for glycosylated hemoglobin as measured by ion-exchange chromatography, affinity chromatography, and colorimetry. Little RR, England JD, Wiedmeyer HM, Goldstein DE. Clin Chem; 1983 Jun 18; 29(6):1113-5. PubMed ID: 6851106 [Abstract] [Full Text] [Related]
9. Determination of glycosylated hemoglobin by affinity chromatography: comparison with colorimetric and ion-exchange methods, and effects of common interferences. Klenk DC, Hermanson GT, Krohn RI, Fujimoto EK, Mallia AK, Smith PK, England JD, Wiedmeyer HM, Little RR, Goldstein DE. Clin Chem; 1982 Oct 18; 28(10):2088-94. PubMed ID: 7127736 [Abstract] [Full Text] [Related]
10. Quantitation of glycosylated hemoglobin by boronate affinity chromatography. Flückiger R, Woodtli T, Berger W. Diabetes; 1984 Jan 18; 33(1):73-6. PubMed ID: 6690345 [Abstract] [Full Text] [Related]
11. Determination of glycosylated adult and foetal haemoglobins by affinity chromatography. Talwar D, Barr BB, Kesson CM, Robb DA. Clin Chim Acta; 1983 Feb 28; 128(1):61-7. PubMed ID: 6188558 [Abstract] [Full Text] [Related]
12. Glycosylated hemoglobins: increased glycosylation of hemoglobin A in diabetic patients. Gabbay KH, Sosenko JM, Banuchi GA, Mininsohn MJ, Flückiger R. Diabetes; 1979 Apr 28; 28(4):337-40. PubMed ID: 437373 [Abstract] [Full Text] [Related]
13. Hemoglobin Raleigh as the cause of a falsely increased hemoglobin A1C in an automated ion-exchange HPLC method. Chen D, Crimmins DL, Hsu FF, Lindberg FP, Scott MG. Clin Chem; 1998 Jun 28; 44(6 Pt 1):1296-301. PubMed ID: 9625056 [Abstract] [Full Text] [Related]
17. Effects of azotemia on results of the boronate-agarose affinity and ion-exchange methods for glycated hemoglobin. Scott MG, Hoffmann JW, Meltzer VN, Siegfried BA, Chan KM. Clin Chem; 1984 Jun 28; 30(6):896-8. PubMed ID: 6723047 [Abstract] [Full Text] [Related]
18. Application of shielding boronate affinity chromatography in the study of the glycation pattern of haemoglobin. Li Y, Jeppsson JO, Jörntén-Karlsson M, Linné Larsson E, Jungvid H, Galaev IY, Mattiasson B. J Chromatogr B Analyt Technol Biomed Life Sci; 2002 Sep 05; 776(2):149-60. PubMed ID: 12137996 [Abstract] [Full Text] [Related]