These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
122 related items for PubMed ID: 6427131
1. Comparative study of glomerular filtration rate with diverse labelled agents. Eberstadt PL. Int Urol Nephrol; 1984; 16(1):3-11. PubMed ID: 6427131 [Abstract] [Full Text] [Related]
2. Utility of radioisotopic filtration markers in chronic renal insufficiency: simultaneous comparison of 125I-iothalamate, 169Yb-DTPA, 99mTc-DTPA, and inulin. The Modification of Diet in Renal Disease Study. Perrone RD, Steinman TI, Beck GJ, Skibinski CI, Royal HD, Lawlor M, Hunsicker LG. Am J Kidney Dis; 1990 Sep; 16(3):224-35. PubMed ID: 2205098 [Abstract] [Full Text] [Related]
3. Comparison of inulin, iothalamate, and 99mTc-DTPA for measurement of glomerular filtration rate. Barbour GL, Crumb CK, Boyd CM, Reeves RD, Rastogi SP, Patterson RM. J Nucl Med; 1976 Apr; 17(4):317-20. PubMed ID: 1255261 [Abstract] [Full Text] [Related]
4. Simultaneous measurement of renal clearance and plasma clearance of 99mTc-labelled diethylenetriaminepenta-acetate, 51Cr-labelled ethylenediaminetetra-acetate and inulin in man. Rehling M, Møller ML, Thamdrup B, Lund JO, Trap-Jensen J. Clin Sci (Lond); 1984 May; 66(5):613-9. PubMed ID: 6423339 [Abstract] [Full Text] [Related]
5. Reliability of a 99mTc-DTPA gamma camera technique for determination of single kidney glomerular filtration rate. A comparison to plasma clearance of 51Cr-EDTA in one-kidney patients, using the renal clearance of inulin as a reference. Rehling M, Møller ML, Thamdrup B, Lund JO, Trap-Jensen J. Scand J Urol Nephrol; 1986 May; 20(1):57-62. PubMed ID: 3085214 [Abstract] [Full Text] [Related]
6. Measurement of glomerular filtration rate via urinary clearance of inulin and plasma clearance of technetium Tc 99m pentetate and exogenous creatinine in dogs. Finco DR. Am J Vet Res; 2005 Jun; 66(6):1046-55. PubMed ID: 16008230 [Abstract] [Full Text] [Related]
7. Comparison of methods for calculating glomerular filtration rate: technetium-99m-DTPA scintigraphic analysis, protein-free and whole-plasma clearance of technetium-99m-DTPA and iodine-125-iothalamate clearance. Goates JJ, Morton KA, Whooten WW, Greenberg HE, Datz FL, Handy JE, Scuderi AJ, Haakenstad AO, Lynch RE. J Nucl Med; 1990 Apr; 31(4):424-9. PubMed ID: 2182797 [Abstract] [Full Text] [Related]
8. Determination of glomerular filtration rate using technetium-99m-DTPA with differing degrees of renal function. Morton KA, Pisani DE, Whiting JH, Cheung AK, Arias JM, Valdivia S. J Nucl Med Technol; 1997 Jun; 25(2):110-4. PubMed ID: 9239614 [Abstract] [Full Text] [Related]
9. Comparison of 51Cr-EDTA and 99mTc-DTPA slope clearances in children with vesicoureteric reflux. Griffiths PD, Drolc Z, Green A, Taylor CM, White RH. Child Nephrol Urol; 1997 Jun; 9(5):283-5. PubMed ID: 3152160 [Abstract] [Full Text] [Related]
10. Radionuclide measurement of differential glomerular filtration rate in urinary tract obstruction. Powers TA, Stone WJ, Lowe BA, Patton JA, Bowen RD. Invest Radiol; 1982 Jun; 17(4):417-21. PubMed ID: 6290414 [Abstract] [Full Text] [Related]
11. Post-transplant glomerular filtration rate as a marker for long-term outcome. Pouteil-Noble C, Maiza H, Remontet L. Ann Transplant; 2000 Jun; 5(2):29-36. PubMed ID: 11217204 [No Abstract] [Full Text] [Related]
12. Correlation of I-125 iothalamate and tc-99m DPTA measurements of GFR using the single injection method. Wiener SN, Shah YP, Mares RM, Flynn MJ. Clin Nucl Med; 1982 Aug; 7(8):359-63. PubMed ID: 7049493 [Abstract] [Full Text] [Related]
13. 113mIn-DTPA, a useful compound for the determination of glomerular filtration rate (GFR). The binding of 113mIn to DTPA and a comparison between GFR estimated with 113mIn-DTPA and 125I-iothalamate. Johansson RS, Falch DK. Eur J Nucl Med; 1978 Jul 01; 3(3):179-81. PubMed ID: 738287 [Abstract] [Full Text] [Related]
15. Cadmium telluride detectors in the external measurement of glomerular filtration rate using 99mTc-DTPA (Sn): comparison with 51Cr-EDTA and 99mTc-DTPA (Sn) plasma sample methods. Owen JE, Walker RG, Willems D, Guignard PA, d'Apice AJ. Clin Nephrol; 1982 Oct 01; 18(4):200-3. PubMed ID: 6814803 [Abstract] [Full Text] [Related]
16. Radionuclide measurement of differential glomerular filtration rate. Powers TA, Stone WJ, Grove RB, Plunkett JM, Kadir S, Patton JA, Bowen RD. Invest Radiol; 1981 Oct 01; 16(1):59-64. PubMed ID: 6260704 [Abstract] [Full Text] [Related]
17. Measurement of glomerular filtration rate in children using technetium-99m diethylenetriamine penta-acetic acid. Aaronson IA, Mann MD. S Afr Med J; 1985 Mar 30; 67(13):507-9. PubMed ID: 3885427 [Abstract] [Full Text] [Related]
18. [Comparison of 51Cr-EDTA with 99m-Tc-DTPA slope clearance for estimation of glomerular filtration rate using the one compartment model]. Chapot C, Seifert H, Samnick S, Kirsch CM. Nuklearmedizin; 1998 Jun 30; 37(4):124-8. PubMed ID: 9650211 [Abstract] [Full Text] [Related]
19. Evaluation of 99m Tc-DTPA for the measurement of glomerular filtration rate. Klopper JF, Hauser W, Atkins HL, Eckelman WC, Richards P. J Nucl Med; 1972 Jan 30; 13(1):107-10. PubMed ID: 5007959 [No Abstract] [Full Text] [Related]
20. Radioisotopic measurement of glomerular filtration rate in severe chronic renal failure. LaFrance ND, Drew HH, Walser M. J Nucl Med; 1988 Dec 30; 29(12):1927-30. PubMed ID: 3057129 [Abstract] [Full Text] [Related] Page: [Next] [New Search]