These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


126 related items for PubMed ID: 6548435

  • 1. A count-dependent filter for smoothing flow cytometric histograms.
    Schuette WH, Shackney SE, MacCollum MA, Smith CA.
    Cytometry; 1984 Sep; 5(5):487-93. PubMed ID: 6548435
    [Abstract] [Full Text] [Related]

  • 2. Count-dependent filter for smoothing bivariate FCM histograms.
    Schuette WH, Shackney SE, Marti GE.
    Cytometry; 1986 May; 7(3):274-80. PubMed ID: 3709307
    [Abstract] [Full Text] [Related]

  • 3. Effects of resolution reduction on data analysis.
    Hunsberger B, Bagwell CB, Herbert D, Bray C, Langweiler M.
    Cytometry A; 2003 Jun; 53(2):103-11. PubMed ID: 12766972
    [Abstract] [Full Text] [Related]

  • 4. A review of techniques and results obtained in one laboratory by an integrated system of methods designed for routine clinical flow cytometric DNA analysis.
    Vindeløv LL, Christensen IJ.
    Cytometry; 1990 Jun; 11(7):753-70. PubMed ID: 2272241
    [Abstract] [Full Text] [Related]

  • 5. Statistical evaluation of cell kinetic data from DNA flow cytometry (FCM) by the EM algorithm.
    Baldetorp B, Dalberg M, Holst U, Lindgren G.
    Cytometry; 1989 Nov; 10(6):695-705. PubMed ID: 2582959
    [Abstract] [Full Text] [Related]

  • 6. Quadratic form: a robust metric for quantitative comparison of flow cytometric histograms.
    Bernas T, Asem EK, Robinson JP, Rajwa B.
    Cytometry A; 2008 Aug; 73(8):715-26. PubMed ID: 18561196
    [Abstract] [Full Text] [Related]

  • 7. Flow cytometry histograms: transformations, resolution, and display.
    Novo D, Wood J.
    Cytometry A; 2008 Aug; 73(8):685-92. PubMed ID: 18615596
    [Abstract] [Full Text] [Related]

  • 8. Conversion of linear histogram flow cytometry data to a logarithmic display.
    Brunk CF, Bohman RE, Brunk CA.
    Cytometry; 1982 Sep; 3(2):138-41. PubMed ID: 6897221
    [Abstract] [Full Text] [Related]

  • 9. Automated peak detection and cell cycle analysis of flow cytometric DNA histograms.
    Kallioniemi OP, Visakorpi T, Holli K, Isola JJ, Rabinovitch PS.
    Cytometry; 1994 Jul 01; 16(3):250-5. PubMed ID: 7924694
    [Abstract] [Full Text] [Related]

  • 10. Modified histogram subtraction technique for analysis of flow cytometry data.
    Overton WR.
    Cytometry; 1988 Nov 01; 9(6):619-26. PubMed ID: 3061754
    [Abstract] [Full Text] [Related]

  • 11. High resolution method for the analysis of DNA histograms that is suitable for the detection of multiple aneuploid G1 peaks in clinical samples.
    Schuette WH, Shackney SE, MacCollum MA, Smith CA.
    Cytometry; 1983 Mar 01; 3(5):376-86. PubMed ID: 6839887
    [Abstract] [Full Text] [Related]

  • 12. Mathematical evaluation of two parameter flow cytometric histograms.
    Scholz KU.
    Cytometry; 1981 Nov 01; 2(3):159-64. PubMed ID: 6170498
    [Abstract] [Full Text] [Related]

  • 13. Parametric analysis of histograms measured in flow cytometry.
    Mann RC, Hand RE, Braslawsky GR.
    Cytometry; 1983 Jul 01; 4(1):75-82. PubMed ID: 6617397
    [Abstract] [Full Text] [Related]

  • 14. Data analysis of two-parameter flow cytometric measurements.
    Scholz KU.
    Anal Quant Cytol; 1981 Dec 01; 3(4):323-9. PubMed ID: 7036811
    [Abstract] [Full Text] [Related]

  • 15. A method to estimate cell cycle time and growth fraction using bromodeoxyuridine-flow cytometry data from a single sample.
    Eidukevicius R, Characiejus D, Janavicius R, Kazlauskaite N, Pasukoniene V, Mauricas M, Den Otter W.
    BMC Cancer; 2005 Sep 22; 5():122. PubMed ID: 16176590
    [Abstract] [Full Text] [Related]

  • 16. Evaluation of the S phase distribution of flow cytometric DNA histograms by autoradiography and computer algorithms.
    Sheck LE, Muirhead KA, Horan PK.
    Cytometry; 1980 Sep 22; 1(2):109-17. PubMed ID: 7297344
    [Abstract] [Full Text] [Related]

  • 17. Spectral analysis of flow cytometric data: design of a special-purpose low-pass digital filter.
    Sloot PM, Tensen P, Figdor CG.
    Cytometry; 1987 Nov 22; 8(6):545-51. PubMed ID: 3428039
    [Abstract] [Full Text] [Related]

  • 18. [Mathematical methods in flow cytometry: the problem of evaluating DNA histograms of partially synchronous cell populations].
    Schmidt W, Langen P, Graetz H, Lehmann W.
    Acta Biol Med Ger; 1982 Nov 22; 41(9):787-99. PubMed ID: 7164698
    [Abstract] [Full Text] [Related]

  • 19. A new flow cytometric pulse height analyzer offering microprocessor controlled data acquisition and statistical analysis.
    Kachel V, Schneider H, Schedler K.
    Cytometry; 1980 Nov 22; 1(3):175-92. PubMed ID: 7021102
    [Abstract] [Full Text] [Related]

  • 20. Flow cytometric S-phase fraction measurement in breast carcinoma: Influence of software and histogram resolution.
    Jourdan ML, Ferrero-Poüs M, Spyratos F, Romain S, Martin PM, Chassevent A.
    Cytometry; 2002 Jun 01; 48(2):66-70. PubMed ID: 12116366
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 7.