These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


121 related items for PubMed ID: 6671984

  • 1.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 2. Steady flow development past valve prostheses in a model human aorta. I. Centrally occluding valves.
    Khalighi B, Chandran KB, Chen CJ.
    J Biomech; 1983; 16(12):1003-11. PubMed ID: 6671983
    [Abstract] [Full Text] [Related]

  • 3. Experimental study of physiological pulsatile flow past valve prosthesis in a model of human aorta--II. Tilting disc valves and the effect of orientation.
    Chandran KB, Khalighi B, Chen CJ.
    J Biomech; 1985; 18(10):773-80. PubMed ID: 4066720
    [Abstract] [Full Text] [Related]

  • 4. Effect of valve orientation on flow development past aortic valve prostheses in a model human aorta.
    Chandran KB, Khalighi B, Chen CJ, Falsetti HL, Yearwood TL, Hiratzka LF.
    J Thorac Cardiovasc Surg; 1983 Jun; 85(6):893-901. PubMed ID: 6855259
    [Abstract] [Full Text] [Related]

  • 5. Pulsatile flow past aortic valve bioprostheses in a model human aorta.
    Chandran KB, Cabell GN, Khalighi B, Chen CJ.
    J Biomech; 1984 Jun; 17(8):609-19. PubMed ID: 6490673
    [Abstract] [Full Text] [Related]

  • 6. Experimental study of physiological pulsatile flow past valve prostheses in a model of human aorta--I. Caged ball valves.
    Chandran KB, Khalighi B, Chen CJ.
    J Biomech; 1985 Jun; 18(10):763-72. PubMed ID: 2933409
    [Abstract] [Full Text] [Related]

  • 7. Velocity field of a Björk-Shiley valve prosthesis: influence of the disc orientation.
    Farahifar D, Bodard H, Cassot F, Pelissier R.
    Cardiovasc Res; 1987 Feb; 21(2):90-8. PubMed ID: 3664546
    [Abstract] [Full Text] [Related]

  • 8. In vitro pulsatile flow measurements in the vicinity of mechanical heart valves in the mitral flow chamber.
    Woo YR, Yoganathan AP.
    Life Support Syst; 1986 Feb; 4(2):115-39. PubMed ID: 2943945
    [Abstract] [Full Text] [Related]

  • 9. In vitro fluid dynamic characteristics of the Medtronic-Hall pivoting disc heart valve prosthesis.
    Yoganathan AP, Stevenson DM, Williams FP, Woo YR, Franch RH, Harrison EC.
    Scand J Thorac Cardiovasc Surg; 1982 Feb; 16(3):235-43. PubMed ID: 6221405
    [Abstract] [Full Text] [Related]

  • 10.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 11.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 12. In vitro velocity and turbulence measurements in the vicinity of three new mechanical aortic heart valve prostheses: Björk-Shiley Monostrut, Omni-Carbon, and Duromedics.
    Yoganathan AP, Sung HW, Woo YR, Jones M.
    J Thorac Cardiovasc Surg; 1988 May; 95(5):929-39. PubMed ID: 3361941
    [Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14. In vitro flow dynamics of four prosthetic aortic valves: a comparative analysis.
    Hanle DD, Harrison EC, Yoganathan AP, Allen DT, Corcoran WH.
    J Biomech; 1989 May; 22(6-7):597-607. PubMed ID: 2808443
    [Abstract] [Full Text] [Related]

  • 15. Velocity and shear stress distribution downstream of mechanical heart valves in pulsatile flow.
    Giersiepen M, Krause U, Knott E, Reul H, Rau G.
    Int J Artif Organs; 1989 Apr; 12(4):261-9. PubMed ID: 2722280
    [Abstract] [Full Text] [Related]

  • 16. In vitro pulsatile flow velocity and turbulent shear stress measurements in the vicinity of mechanical aortic heart valve prostheses.
    Woo YR, Yoganathan AP.
    Life Support Syst; 1985 Apr; 3(4):283-312. PubMed ID: 4068753
    [Abstract] [Full Text] [Related]

  • 17. Variability of regurgitation in Björk-Shiley mitral valves and relationship to disc occluder design: an in vitro two-dimensional color-Doppler flow mapping study.
    Lindower PD, Dellsperger KC, Johnson B, Chandran KB, Vandenberg BF.
    J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S178-83. PubMed ID: 8905518
    [Abstract] [Full Text] [Related]

  • 18. Three-dimensional visualization of velocity fields downstream of six mechanical aortic valves in a pulsatile flow model.
    Hasenkam JM, Giersiepen M, Reul H.
    J Biomech; 1988 Aug; 21(8):647-61. PubMed ID: 3170619
    [Abstract] [Full Text] [Related]

  • 19. Velocity and turbulence measurements past mitral valve prostheses in a model left ventricle.
    Schoephoerster RT, Chandran KB.
    J Biomech; 1991 Aug; 24(7):549-62. PubMed ID: 1880139
    [Abstract] [Full Text] [Related]

  • 20. Bileaflet, tilting disc and porcine aortic valve substitutes: in vitro hydrodynamic characteristics.
    Yoganathan AP, Chaux A, Gray RJ, Woo YR, DeRobertis M, Williams FP, Matloff JM.
    J Am Coll Cardiol; 1984 Feb; 3(2 Pt 1):313-20. PubMed ID: 6693619
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 7.