These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
166 related items for PubMed ID: 6695664
1. Evaluation of blood flow velocity in the ascending aorta and main pulmonary artery of normal subjects by Doppler echocardiography. Gardin JM, Burn CS, Childs WJ, Henry WL. Am Heart J; 1984 Feb; 107(2):310-9. PubMed ID: 6695664 [Abstract] [Full Text] [Related]
2. Evaluation of dilated cardiomyopathy by pulsed Doppler echocardiography. Gardin JM, Iseri LT, Elkayam U, Tobis J, Childs W, Burn CS, Henry WL. Am Heart J; 1983 Nov; 106(5 Pt 1):1057-65. PubMed ID: 6637764 [Abstract] [Full Text] [Related]
3. Evaluation of pulmonary artery pressure and resistance by pulsed Doppler echocardiography. Dabestani A, Mahan G, Gardin JM, Takenaka K, Burn C, Allfie A, Henry WL. Am J Cardiol; 1987 Mar 01; 59(6):662-8. PubMed ID: 3825910 [Abstract] [Full Text] [Related]
6. Doppler echocardiographic comparison of flows distal to the four cardiac valves. Loeber CP, Goldberg SJ, Allen HD. J Am Coll Cardiol; 1984 Aug 01; 4(2):268-72. PubMed ID: 6736467 [Abstract] [Full Text] [Related]
7. Doppler blood velocity in the pulmonary artery of infants, children, and adults. Targett RC, Heldt GP, McIlroy MB. Cardiovasc Res; 1986 Nov 01; 20(11):816-21. PubMed ID: 3304640 [Abstract] [Full Text] [Related]
8. A pulsed Doppler echocardiographic study of the postnatal changes in pulmonary artery and ascending aortic flow in normal term newborn infants. Takenaka K, Waffarn F, Dabestani A, Gardin JM, Henry WL. Am Heart J; 1987 Mar 01; 113(3):759-66. PubMed ID: 3825866 [Abstract] [Full Text] [Related]
9. Doppler flow velocity mapping in an in vitro model of the normal pulmonary artery. Gardin JM, Sung HW, Yoganathan AP, Ball J, McMillan S, Henry WL. J Am Coll Cardiol; 1988 Nov 01; 12(5):1366-76. PubMed ID: 2971705 [Abstract] [Full Text] [Related]
10. [Hemodynamic determinants of late systolic reversed flow in the main pulmonary artery in pulmonary hypertension: a pulsed Doppler echocardiographic study]. Koizumi K, Tohda E, Kashida M, Isobe M, Kuwako K, Umeda T, Machii K. J Cardiogr; 1984 Aug 01; 14(2):359-74. PubMed ID: 6533197 [Abstract] [Full Text] [Related]
11. Pulsed Doppler findings in patients with coarctation of the aorta. Shaddy RE, Snider AR, Silverman NH, Lutin W. Circulation; 1986 Jan 01; 73(1):82-8. PubMed ID: 3940672 [Abstract] [Full Text] [Related]
12. Pulmonary and aortic blood flow measurements in normal subjects and patients after single lung transplantation at 0.5 T using velocity encoded cine MRI. Henk CB, Schlechta B, Grampp S, Gomischek G, Klepetko W, Mostbeck GH. Chest; 1998 Sep 01; 114(3):771-9. PubMed ID: 9743165 [Abstract] [Full Text] [Related]
13. Noninvasive evaluation of pulmonary hypertension by a pulsed Doppler technique. Kitabatake A, Inoue M, Asao M, Masuyama T, Tanouchi J, Morita T, Mishima M, Uematsu M, Shimazu T, Hori M, Abe H. Circulation; 1983 Aug 01; 68(2):302-9. PubMed ID: 6861308 [Abstract] [Full Text] [Related]
14. Acceleration time in the aorta and pulmonary artery measured by Doppler echocardiography in the midtrimester normal human fetus. Machado MV, Chita SC, Allan LD. Br Heart J; 1987 Jul 01; 58(1):15-8. PubMed ID: 3620237 [Abstract] [Full Text] [Related]
15. Doppler cardiac output and left ventricular performance after cardiac surgery. Pulsed Doppler ascending aorta and pulmonary blood flows and left ventricular function using implanted microprobes. Fratacci MD, Payen D, Beloucif S, Laborde F. Chest; 1992 Aug 01; 102(2):380-6. PubMed ID: 1643918 [Abstract] [Full Text] [Related]
16. Prediction of pulmonary arterial pressure in adults by pulsed Doppler echocardiography. Isobe M, Yazaki Y, Takaku F, Koizumi K, Hara K, Tsuneyoshi H, Yamaguchi T, Machii K. Am J Cardiol; 1986 Feb 01; 57(4):316-21. PubMed ID: 3946222 [Abstract] [Full Text] [Related]
17. [Determination of normal values of the aortic blood flow profile using continuous Doppler echocardiography from apical and suprasternal echo position]. Gabrielsen FG, Bonnekoh A, Felder C, Eggeling T, Kochs M, Hilger HH, Hombach V. Z Kardiol; 1992 Jan 01; 81(1):30-6. PubMed ID: 1570726 [Abstract] [Full Text] [Related]
18. Is noninvasive determination of pulmonary artery pressure feasible using deceleration phase Doppler flow velocity characteristics in mechanically ventilated children with congenital heart disease? van Dijk AP, Hopman JC, Klaessens JH, van der Werf T, Daniëls O. Am J Cardiol; 1996 Dec 15; 78(12):1394-9. PubMed ID: 8970413 [Abstract] [Full Text] [Related]
19. Doppler echocardiographic measurement of flow velocity in the ascending aorta during supine and upright exercise. Daley PJ, Sagar KB, Wann LS. Br Heart J; 1985 Dec 15; 54(6):562-7. PubMed ID: 4074587 [Abstract] [Full Text] [Related]
20. Normal intracardiac and great artery blood velocity measurements by pulsed Doppler echocardiography. Wilson N, Goldberg SJ, Dickinson DF, Scott O. Br Heart J; 1985 Apr 15; 53(4):451-8. PubMed ID: 3986059 [Abstract] [Full Text] [Related] Page: [Next] [New Search]