These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


189 related items for PubMed ID: 672815

  • 1. Fast and slow neutrons in an 18-MV photon beam from a Philips SL/75-20 linear accelerator.
    Gur D, Rosen JC, Bukovitz AG, Gill AW.
    Med Phys; 1978; 5(3):221-2. PubMed ID: 672815
    [Abstract] [Full Text] [Related]

  • 2. Fast neutrons from a 25-MeV betatron.
    Fox JG, McAllister JD.
    Med Phys; 1977; 4(5):387-96. PubMed ID: 409919
    [Abstract] [Full Text] [Related]

  • 3. Relative measurements of fast neutron contamination in 18-MV photon beams from two linear accelerators and a betatron.
    Gur D, Bukovitz G, Rosen JC, Holmes BG.
    Med Phys; 1979; 6(2):140-1. PubMed ID: 460063
    [Abstract] [Full Text] [Related]

  • 4. Neutron source strength measurements for Varian, Siemens, Elekta, and General Electric linear accelerators.
    Followill DS, Stovall MS, Kry SF, Ibbott GS.
    J Appl Clin Med Phys; 2003; 4(3):189-94. PubMed ID: 12841788
    [Abstract] [Full Text] [Related]

  • 5. Dose levels due to neutrons in the vicinity of high-energy medical accelerators.
    McGinley PH, Wood M, Mills M, Rodriguez R.
    Med Phys; 1976; 3(6):397-402. PubMed ID: 826776
    [Abstract] [Full Text] [Related]

  • 6. Fast and thermal neutron profiles for a 25-MV x-ray beam.
    Price KW, Nath R, Holeman GR.
    Med Phys; 1978; 5(4):285-9. PubMed ID: 98695
    [Abstract] [Full Text] [Related]

  • 7. THERMAL AND FAST NEUTRON DOSE EQUIVALENT DISTRIBUTION MEASUREMENT OF 15-MV LINEAR ACCELERATOR USING A CR-39 NUCLEAR TRACK DETECTORS.
    Mohammadi S, Behmadi M, Mohammadi A, Toossi MTB.
    Radiat Prot Dosimetry; 2020 Jul 02; 188(4):503-507. PubMed ID: 32025737
    [Abstract] [Full Text] [Related]

  • 8. Study on the measurement of photo-neutron for15 MV photon beam from medical linear accelerator under different irradiation geometries using passive detectors.
    Thekkedath SC, Raman RG, Musthafa MM, Bakshi AK, Pal R, Dawn S, Kummali AH, Huilgol NG, Selvam TP, Datta D.
    J Cancer Res Ther; 2016 Jul 02; 12(2):1060-4. PubMed ID: 27461699
    [Abstract] [Full Text] [Related]

  • 9. Neutron dosimetry in high energy X-ray beams of medical accelerators.
    Sohrabi M, Morgan KZ.
    Phys Med Biol; 1979 Jul 02; 24(4):756-66. PubMed ID: 112596
    [Abstract] [Full Text] [Related]

  • 10. Investigating in-field and out-of-field neutron contamination in high-energy medical linear accelerators based on the treatment factors of field size, depth, beam modifiers, and beam type.
    Biltekin F, Yeginer M, Ozyigit G.
    Phys Med; 2015 Jul 02; 31(5):517-23. PubMed ID: 25873196
    [Abstract] [Full Text] [Related]

  • 11. In-phantom dosimetry and spectrometry of photoneutrons from an 18 MV linear accelerator.
    d'Errico F, Nath R, Tana L, Curzio G, Alberts WG.
    Med Phys; 1998 Sep 02; 25(9):1717-24. PubMed ID: 9775378
    [Abstract] [Full Text] [Related]

  • 12. Neutron spectra and dosimetric features around an 18 mv linac accelerator.
    Barquero R, Mendez R, Vega-Carrillo HR, Iñiguez MP, Edwards TM.
    Health Phys; 2005 Jan 02; 88(1):48-58. PubMed ID: 15596989
    [Abstract] [Full Text] [Related]

  • 13. Neutron energies in medical electron accelerator rooms.
    LaRiviere PD.
    Med Phys; 1985 Jan 02; 12(6):769-75. PubMed ID: 4079870
    [Abstract] [Full Text] [Related]

  • 14. Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.
    Chibani O, Ma CM.
    Med Phys; 2003 Aug 02; 30(8):1990-2000. PubMed ID: 12945965
    [Abstract] [Full Text] [Related]

  • 15. Neutron spectral measurements in an intense photon field associated with a high-energy x-ray radiotherapy machine.
    Holeman GR, Price KW, Friedman LF, Nath R.
    Med Phys; 1977 Aug 02; 4(6):508-15. PubMed ID: 412048
    [Abstract] [Full Text] [Related]

  • 16. Neutron leakage measurements from a medical linear accelerator.
    Palta JR, Hogstrom KR, Tannanonta C.
    Med Phys; 1984 Aug 02; 11(4):498-501. PubMed ID: 6434916
    [Abstract] [Full Text] [Related]

  • 17. Neutron dose equivalent measured at the maze door with various openings for the jaws and MLC.
    Krmar M, Baucal M, Bozic N, Jovancevic N, Ciraj-Bjelac O.
    Med Phys; 2012 Mar 02; 39(3):1278-81. PubMed ID: 22380359
    [Abstract] [Full Text] [Related]

  • 18. Experimental determination of thermal neutron fluence around Elekta Versa HD linear accelerator for various photon energies.
    Vysakh R, Musthafa MM, Midhun CV, Niyas P, Anjana PT, Krishnan MPA, Ranjith CP, Irfad MP, Ganapathi Raman R.
    Biomed Phys Eng Express; 2020 Sep 08; 6(5):055018. PubMed ID: 33444249
    [Abstract] [Full Text] [Related]

  • 19. Phosphorus activation neutron dosimetry and its application to an 18-MV radiotherapy accelerator.
    Bading JR, Zeitz L, Laughlin JS.
    Med Phys; 1982 Sep 08; 9(6):835-43. PubMed ID: 6819434
    [Abstract] [Full Text] [Related]

  • 20. A Monte Carlo study on neutron and electron contamination of an unflattened 18-MV photon beam.
    Mesbahi A.
    Appl Radiat Isot; 2009 Jan 08; 67(1):55-60. PubMed ID: 18760613
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 10.