These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


164 related items for PubMed ID: 6749451

  • 1. [Current possibilities of reconstruction of the lower jaw in bony defects following tumor resection. Animal experiments and clinical results].
    Raveh J, Stich H, Sutter F, Greiner R.
    Chirurg; 1982 Jul; 53(7):459-67. PubMed ID: 6749451
    [Abstract] [Full Text] [Related]

  • 2. New concepts in the reconstruction of mandibular defects following tumor resection.
    Raveh Y, Stich H, Sutter F, Greiner R.
    J Oral Maxillofac Surg; 1983 Jan; 41(1):3-16. PubMed ID: 6571737
    [Abstract] [Full Text] [Related]

  • 3. [Titanium-coated hollow screw and reconstruction plate system for the bridging of jaw defects. II. Possible reconstruction variants with the THRP system].
    Raveh J, Stich H, Sutter F.
    Chirurg; 1985 May; 56(5):337-44. PubMed ID: 3891246
    [Abstract] [Full Text] [Related]

  • 4. [Titanium plasma-coated hollow screws and reconstruction plate system for the bridging of jaw defects. I. Basic principles and biomechanical properties].
    Sutter F, Raveh J, Schürch H, Stich H.
    Chirurg; 1984 Nov; 55(11):741-8. PubMed ID: 6510088
    [No Abstract] [Full Text] [Related]

  • 5. [The use of titanium mesh plates for graft fixation in mandibular osteoplasty].
    Temerkhanov FT, Piatnitskiĭ BG, Iurmazov NB.
    Stomatologiia (Mosk); 1998 Nov; 77(6):31-3. PubMed ID: 10067412
    [Abstract] [Full Text] [Related]

  • 6. Surgical procedures for reconstruction of the lower jaw using the titanium-coated hollow-screw reconstruction plate system: bridging of defects.
    Raveh J, Sutter F, Hellem S.
    Otolaryngol Clin North Am; 1987 Aug; 20(3):535-58. PubMed ID: 3684291
    [Abstract] [Full Text] [Related]

  • 7. [Immediate reconstruction of mandibular defects following tumor surgery with Ti-plate system].
    Zhang Y.
    Zhonghua Kou Qiang Yi Xue Za Zhi; 1994 Jan; 29(1):3-5, 62. PubMed ID: 7995131
    [Abstract] [Full Text] [Related]

  • 8. Primary mandibular reconstruction: analysis of 64 cases and evaluation of interface radiation dosimetry on bridging plates.
    Gullane PJ.
    Laryngoscope; 1991 Jun; 101(6 Pt 2 Suppl 54):1-24. PubMed ID: 2041453
    [Abstract] [Full Text] [Related]

  • 9. Use of the titanium-coated hollow screw and reconstruction plate system in bridging of lower jaw defects.
    Raveh J, Stich H, Sutter F, Greiner R.
    J Oral Maxillofac Surg; 1984 May; 42(5):281-94. PubMed ID: 6371200
    [Abstract] [Full Text] [Related]

  • 10. Mandibular reconstruction with the titanium hollow screw reconstruction plate (THORP) system: evaluation of 62 cases.
    Vuillemin T, Raveh J, Sutter F.
    Plast Reconstr Surg; 1988 Nov; 82(5):804-14. PubMed ID: 3174870
    [Abstract] [Full Text] [Related]

  • 11. Analysis of complications after reconstruction of bone defects involving complete mandibular resection using finite element modelling.
    Markwardt J, Pfeifer G, Eckelt U, Reitemeier B.
    Onkologie; 2007 Mar; 30(3):121-6. PubMed ID: 17341898
    [Abstract] [Full Text] [Related]

  • 12. [Bridging of the defect by the lingual approach and bone graft fixation in the mandible with the THRP (titanium-coated hollow-screw and reconstruction plate) system].
    Raveh J, Sutter F.
    Schweiz Monatsschr Zahnmed (1984); 1984 Feb; 94(2):134-42. PubMed ID: 6367030
    [No Abstract] [Full Text] [Related]

  • 13. [A retrospective study of 541 cases with segmental resection of mandible].
    Ji T, Zhang CP.
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2006 Dec; 41(12):705-8. PubMed ID: 17349186
    [Abstract] [Full Text] [Related]

  • 14. [Lower jaw reconstruction using titanium mesh and removal of iliac crest grafts while maintaining the crista contour].
    Cesteleyn L, Akuamoa-Boateng E.
    Acta Stomatol Belg; 1985 Jun; 82(2):85-94. PubMed ID: 3895851
    [No Abstract] [Full Text] [Related]

  • 15. [Light microscopic observation of bone interface of titanium-coated 317L plate screw].
    Yao X, Zhu M, Yin X.
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 1997 Dec; 14(4):327-9. PubMed ID: 11367620
    [Abstract] [Full Text] [Related]

  • 16. Efficacy of small reconstruction plates in vascularized bone graft mandibular reconstruction.
    Farwell DG, Kezirian EJ, Heydt JL, Yueh B, Futran ND.
    Head Neck; 2006 Jul; 28(7):573-9. PubMed ID: 16755584
    [Abstract] [Full Text] [Related]

  • 17. [New reconstruction potentials in mandibular defects after tumor resection].
    Raveh J, Stich H, Sutter F, Schawalder P.
    SSO Schweiz Monatsschr Zahnheilkd; 1981 Nov; 91(11):899-920. PubMed ID: 7031877
    [No Abstract] [Full Text] [Related]

  • 18. [Can steel screws be combined with titanium plates? Hard polishing technique and SEM in animal experiments].
    Wächter R, Stoll P.
    Dtsch Z Mund Kiefer Gesichtschir; 1991 Nov; 15(4):275-84. PubMed ID: 1816958
    [Abstract] [Full Text] [Related]

  • 19. Reconstruction of segmental mandibular defects by distraction osteogenesis for mandibular reconstruction.
    Kuriakose MA, Shnayder Y, DeLacure MD.
    Head Neck; 2003 Oct; 25(10):816-24. PubMed ID: 12966505
    [Abstract] [Full Text] [Related]

  • 20. Endosseous implant and autogenous bone graft reconstruction of mandibular discontinuity: a 12-year longitudinal study of 31 patients.
    Keller EE, Tolman D, Eckert S.
    Int J Oral Maxillofac Implants; 1998 Oct; 13(6):767-80. PubMed ID: 9857587
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]