These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
82 related items for PubMed ID: 6836676
1. [Mechanical properties of the dura mater of the human brain]. Zhivoderov NN, Zavalishin NN, Neniukov AK. Sud Med Ekspert; 1983; 26(1):36-7. PubMed ID: 6836676 [No Abstract] [Full Text] [Related]
2. [The strength and elasticity of the dura mater]. Kargapol'tseva GV. Vopr Neirokhir; 1975; (1):53-4. PubMed ID: 1119129 [Abstract] [Full Text] [Related]
3. Mechanical Properties of Human Dura Mater in Tension - An Analysis at an Age Range of 2 to 94 Years. Zwirner J, Scholze M, Waddell JN, Ondruschka B, Hammer N. Sci Rep; 2019 Nov 13; 9(1):16655. PubMed ID: 31723169 [Abstract] [Full Text] [Related]
4. [Elasticity and tensile strength of human spinal dura mater]. Haupt W, Stofft E. Verh Anat Ges; 1978 Nov 13; (72):139-44. PubMed ID: 746694 [No Abstract] [Full Text] [Related]
5. [Study of some morphologic aspects of the human dura mater]. Jiang DF. Zhonghua Wai Ke Za Zhi; 1990 Feb 13; 28(2):108-9, 128. PubMed ID: 2364822 [Abstract] [Full Text] [Related]
6. [Evaluation of various characteristics of the human dura mater after preservation in absolute alcohol]. Dias AR, Mazzei FM, Kolbe W, Santos R, Zerbini EJ. Rev Paul Med; 1973 Mar 13; 81(3):137-40. PubMed ID: 4804002 [No Abstract] [Full Text] [Related]
8. [Structure and physicomechanical properties of the human dura mater from the age aspect]. Ziablov VI, Shapovalov IuN, Toskin KD, Tkach VV, Zhebrovskiĭ VV. Arkh Anat Gistol Embriol; 1982 Mar 13; 82(3):29-36. PubMed ID: 7092586 [Abstract] [Full Text] [Related]
11. Lumbar dura mater biomechanics: experimental characterization and scanning electron microscopy observations. Runza M, Pietrabissa R, Mantero S, Albani A, Quaglini V, Contro R. Anesth Analg; 1999 Jun 13; 88(6):1317-21. PubMed ID: 10357337 [Abstract] [Full Text] [Related]
13. Mechanical properties of the human lumbar dura mater. Zarzur E. Arq Neuropsiquiatr; 1996 Sep 13; 54(3):455-60. PubMed ID: 9109991 [Abstract] [Full Text] [Related]
14. [Problem of selection of the dura mater for implant. II: Investigation of some variables possibly interfering with their physical properties]. Raposo-Amaral CM, Pigossi N, Leonardi LS, Mazzei FM. Rev Paul Med; 1978 Sep 13; 91(1-2):6-9. PubMed ID: 635365 [No Abstract] [Full Text] [Related]
15. Autologous skin graft, human dura mater and polypropylene mesh for the repair of ventral abdominal hernias: an experimental study. Kama NA, Coskun T, Yavuz H, Doganay M, Reis E, Akat AZ. Eur J Surg; 1999 Nov 13; 165(11):1080-5. PubMed ID: 10595614 [Abstract] [Full Text] [Related]
19. Biomechanical study of human dura and its substitutes. Zhou L, Song D, Ding Z. Chin Med J (Engl); 2002 Nov 13; 115(11):1657-9. PubMed ID: 12609082 [Abstract] [Full Text] [Related]
20. [Evaluation of the resistance of human dura mater to traction and elongation until rupture. Presentation of a study method]. Dias AR, Mazzei FM, Kolbe W, Zerbini EJ. Arq Bras Cardiol; 1973 Jun 13; 26(3):211-5. PubMed ID: 4781334 [No Abstract] [Full Text] [Related] Page: [Next] [New Search]