These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
217 related items for PubMed ID: 6979489
1. An evaluation of 99mTc-labeled red blood cell scintigraphy for the detection and localization of gastrointestinal bleeding sites. Markisz JA, Front D, Royal HD, Sacks B, Parker JA, Kolodny GM. Gastroenterology; 1982 Aug; 83(2):394-8. PubMed ID: 6979489 [Abstract] [Full Text] [Related]
2. Use of technetium-labeled red blood cell scintigraphy in the detection and management of gastrointestinal hemorrhage. Voeller GR, Bunch G, Britt LG. Surgery; 1991 Oct; 110(4):799-804. PubMed ID: 1925969 [Abstract] [Full Text] [Related]
3. [Clinical value of gastrointestinal bleeding scintigraphy in vivo using 99mTc-labeled erythrocytes]. Heer M, Schaub W, Hany A. Schweiz Med Wochenschr; 1986 Jul 19; 116(29):953-5. PubMed ID: 3020681 [Abstract] [Full Text] [Related]
4. Accurate localization and surgical management of active lower gastrointestinal hemorrhage with technetium-labeled erythrocyte scintigraphy. Suzman MS, Talmor M, Jennis R, Binkert B, Barie PS. Ann Surg; 1996 Jul 19; 224(1):29-36. PubMed ID: 8678614 [Abstract] [Full Text] [Related]
5. Localization of obscure gastrointestinal bleeding by technetium 99m-labeled red blood cell scintigraphy. Wang CS, Tzen KY, Huang MJ, Wang JY, Chen MF. J Formos Med Assoc; 1992 Jan 19; 91(1):63-8. PubMed ID: 1352337 [Abstract] [Full Text] [Related]
6. The accuracy of technetium-99m-labeled red cell scintigraphy in localizing gastrointestinal bleeding. Dusold R, Burke K, Carpentier W, Dyck WP. Am J Gastroenterol; 1994 Mar 19; 89(3):345-8. PubMed ID: 8122642 [Abstract] [Full Text] [Related]
7. The use of technetium-labeled erythrocyte scintigraphy in the evaluation and treatment of lower gastrointestinal hemorrhage. Gutierrez C, Mariano M, Vander Laan T, Wang A, Faddis DM, Stain SC. Am Surg; 1998 Oct 19; 64(10):989-92. PubMed ID: 9764709 [Abstract] [Full Text] [Related]
8. [Improved detection of gastrointestinal bleeding sites with 99mTc market autologous erythrocytes and continuous dynamic scintigraphy with cine-mode display]. Meller J, Schönborn E, Conrad M, Horstmann O, Raddatz D, Becker W. Chirurg; 2000 Mar 19; 71(3):292-9. PubMed ID: 10789046 [Abstract] [Full Text] [Related]
9. Detection of gastrointestinal bleeding by radionuclide scintigraphy. Gupta S, Luna E, Kingsley S, Prince M, Herrera N. Am J Gastroenterol; 1984 Jan 19; 79(1):26-31. PubMed ID: 6318553 [Abstract] [Full Text] [Related]
10. [99mTc red blood cell scintigraphy for the assessment of active gastrointestinal bleeding]. Orellana P, Vial I, Prieto C, Rollán A, Olea E, Quintana JC, Foronda C, Pérez G, Astudillo S. Rev Med Chil; 1998 Apr 19; 126(4):413-8. PubMed ID: 9699372 [Abstract] [Full Text] [Related]
11. [Scintigraphy of bleeding. The diagnostic value based on a 10-year period]. Linnet J, Abrahamsen J. Ugeskr Laeger; 1995 Sep 25; 157(39):5373-7. PubMed ID: 7483048 [Abstract] [Full Text] [Related]
12. Scintigraphic diagnosis of gastrointestinal bleeding with 99mTc-labeled blood-pool agents. Miskowiak J, Nielsen SL, Munck O. Radiology; 1981 Nov 25; 141(2):499-504. PubMed ID: 6457317 [Abstract] [Full Text] [Related]
13. Limited value of technetium 99m-labeled red cell scintigraphy in localization of lower gastrointestinal bleeding. Hunter JM, Pezim ME. Am J Surg; 1990 May 25; 159(5):504-6. PubMed ID: 2334015 [Abstract] [Full Text] [Related]
14. Use of technetium-labeled autologous red blood cells in detection of gastrointestinal bleeding. Friedman HI, Hilts SV, Whitney PJ. Surg Gynecol Obstet; 1983 Apr 25; 156(4):449-52. PubMed ID: 6301085 [Abstract] [Full Text] [Related]
15. [Diagnosis of acute gastrointestinal bleeding using scintigraphy with 99mTc-labeled red blood cells]. Morita S, Ohzono H, Ishibashi M, Hirayama T, Nomura Y, Yoshii T, Takahashi K, Ohtake H, Araki T, Sakamoto T. Kaku Igaku; 1990 May 25; 27(5):459-66. PubMed ID: 2395229 [Abstract] [Full Text] [Related]
16. [Lower gastrointestinal bleeding: contribution of labeled erythrocytes scintigraphy]. Matrane A, Mariaule E, Martin P, Bergmann P. Rev Med Brux; 2009 May 25; 30(1):55-8. PubMed ID: 19353944 [Abstract] [Full Text] [Related]
17. Noninvasive evaluation of active lower gastrointestinal bleeding: comparison between contrast-enhanced MDCT and 99mTc-labeled RBC scintigraphy. Zink SI, Ohki SK, Stein B, Zambuto DA, Rosenberg RJ, Choi JJ, Tubbs DS. AJR Am J Roentgenol; 2008 Oct 25; 191(4):1107-14. PubMed ID: 18806152 [Abstract] [Full Text] [Related]
18. Single-photon emission computed tomography enhanced Tc-99m-pertechnetate disodium-labelled red blood cell scintigraphy in the localization of small intestine bleeding: a single-centre twelve-year study. Dolezal J, Vizda J, Kopacova M. Digestion; 2011 Oct 25; 84(3):207-11. PubMed ID: 21757912 [Abstract] [Full Text] [Related]
19. Evaluation of gastrointestinal bleeding by red blood cells labeled in vivo with technetium-99m. Winzelberg GG, McKusick KA, Strauss HW, Waltman AC, Greenfield AJ. J Nucl Med; 1979 Oct 25; 20(10):1080-6. PubMed ID: 317093 [Abstract] [Full Text] [Related]
20. Localization of gastrointestinal bleeding: superiority of 99mTc sulfur colloid compared with angiography. Alavi A, Ring EJ. AJR Am J Roentgenol; 1981 Oct 25; 137(4):741-8. PubMed ID: 6974970 [Abstract] [Full Text] [Related] Page: [Next] [New Search]