These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
23. External quality assessment for clinical microbiological laboratories in Norway 1982. 1. Evaluation of the identifications of 24 bacterial strains. Lassen J, Sandven P. NIPH Ann; 1983 Jun; 6(1):23-35. PubMed ID: 6621930 [Abstract] [Full Text] [Related]
24. [Comparative evaluation of 3 miniaturized systems (API 20E, Enterotube II, Sensititre AP60) commonly used in clinical microbiology laboratories]. Chiaradia V, Pistello M, Pascoli L, Tarabini Castellani G, Beduz R, Menin A, Santini G. Quad Sclavo Diagn; 1983 Jun; 19(2):159-75. PubMed ID: 6374735 [Abstract] [Full Text] [Related]
25. Comparison of Crystal Enteric/Nonfermenter system, API 20E system, and Vitek AutoMicrobic system for identification of gram-negative bacilli. Robinson A, McCarter YS, Tetreault J. J Clin Microbiol; 1995 Feb; 33(2):364-70. PubMed ID: 7714193 [Abstract] [Full Text] [Related]
27. [Evaluation of API 20 NE (version 6.0) in rare Gram-negative non-glucose-fermenting bacilli]. Vay C, Almuzara M, Mattera J, de Mier C, Famiglietti A. Rev Argent Microbiol; 2003 Feb; 35(3):133-7. PubMed ID: 14587374 [Abstract] [Full Text] [Related]
28. Comparison of enteric identification systems. Borchardt KA, Gibson J. Health Lab Sci; 1977 Jan; 14(1):5-10. PubMed ID: 319082 [Abstract] [Full Text] [Related]
29. Evaluation of the four-hour rapid 20E system for identification of members of the family Enterobacteriaceae. Izard D, Husson MO, Vincent P, Leclerc H, Monget D, Boeufgras JM. J Clin Microbiol; 1984 Jul; 20(1):51-4. PubMed ID: 6378967 [Abstract] [Full Text] [Related]
32. 16S rRNA gene sequencing versus the API 20 NE system and the VITEK 2 ID-GNB card for identification of nonfermenting Gram-negative bacteria in the clinical laboratory. Bosshard PP, Zbinden R, Abels S, Böddinghaus B, Altwegg M, Böttger EC. J Clin Microbiol; 2006 Apr; 44(4):1359-66. PubMed ID: 16597863 [Abstract] [Full Text] [Related]
33. [Use of the API 20E system for rapid identification of Enterobacteriaceae (six hours) (author's transl)]. Pinon G, Loulergue J, Quentin R, Darchis JP, Prieur D, Vargues R. Ann Biol Clin (Paris); 1979 Apr; 37(4):221-3. PubMed ID: 525850 [Abstract] [Full Text] [Related]
34. Evaluation of a new identification system, Crystal Enteric/Non-Fermenter, for gram-negative bacilli. Wauters G, Boel A, Voorn GP, Verhaegen J, Meunier F, Janssens M, Verbist L. J Clin Microbiol; 1995 Apr; 33(4):845-9. PubMed ID: 7790449 [Abstract] [Full Text] [Related]
35. Accuracies of Leuconostoc phenotypic identification: a comparison of API systems and conventional phenotypic assays. Kulwichit W, Nilgate S, Chatsuwan T, Krajiw S, Unhasuta C, Chongthaleong A. BMC Infect Dis; 2007 Jul 02; 7():69. PubMed ID: 17605772 [Abstract] [Full Text] [Related]
36. Comparison of the Quantum II Bacterial Identification System and the AutoMicrobic System for the identification of gram-negative bacilli. Pfaller MA, Bale MJ, Schulte KR, Koontz FP. J Clin Microbiol; 1986 Jan 02; 23(1):1-5. PubMed ID: 3517034 [Abstract] [Full Text] [Related]
37. Comparison of the Microbact-12E and 24E systems and the API-20E system for the identification of Enterobacteriaceae. Mugg P, Hill A. J Hyg (Lond); 1981 Oct 02; 87(2):287-97. PubMed ID: 7026673 [Abstract] [Full Text] [Related]
38. Use of the API 20E, Oxi/Ferm, and Minitek systems to identify nonfermentative and oxidase-positive fermentative bacteria: seven years of experience. Oberhofer TR. Diagn Microbiol Infect Dis; 1983 Sep 02; 1(3):241-56. PubMed ID: 6370567 [Abstract] [Full Text] [Related]
39. Comparison of six systems for the identification of Enterobacteriaceae. Mastroeni P, Carbone M, Fera MT, Teti G. G Batteriol Virol Immunol; 1983 Sep 02; 76(1-6):3-19. PubMed ID: 6383930 [Abstract] [Full Text] [Related]