These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


159 related items for PubMed ID: 7247005

  • 1. [Gas-diffusion induced pressure kinetics in low pressure cuffs. Continuous pressure measurement in vivo and in vitro (author's transl)].
    Brandt L, Renz D, Pokar H.
    Anaesthesist; 1981 Apr; 30(4):200-5. PubMed ID: 7247005
    [Abstract] [Full Text] [Related]

  • 2. [The rediffusion system. Limitation of nitrous oxide increases the cuff pressure of endotracheal tubes].
    Brandt L, Pokar H.
    Anaesthesist; 1983 Sep; 32(9):459-64. PubMed ID: 6638471
    [Abstract] [Full Text] [Related]

  • 3. [Cuff pressure changes due to diffusion of nitrous oxide. A contribution to the question of the in vivo-diffusion--area of the cuff].
    Brandt L, Pokar H, Renz D, Schütte H.
    Anaesthesist; 1982 Jul; 31(7):345-8. PubMed ID: 7125178
    [Abstract] [Full Text] [Related]

  • 4. [Volume and pressure changes due to nitrousoxide diffusion in costumary and in low-pressure cuffs of endotracheal tubes (author's transl)].
    Lanz E, Zimmerschitt W.
    Anaesthesist; 1976 Oct; 25(10):491-8. PubMed ID: 984380
    [Abstract] [Full Text] [Related]

  • 5. Nitrous oxide diffusion into tracheal tube cuffs: comparison of five different tracheal tube cuffs.
    Dullenkopf A, Gerber AC, Weiss M.
    Acta Anaesthesiol Scand; 2004 Oct; 48(9):1180-4. PubMed ID: 15352966
    [Abstract] [Full Text] [Related]

  • 6. Tracheal tube cuff pressures. The effects of different gas mixtures.
    Raeder JC, Borchgrevink PC, Sellevold OM.
    Anaesthesia; 1985 May; 40(5):444-7. PubMed ID: 4014621
    [Abstract] [Full Text] [Related]

  • 7. [The intracuff pressure changes in N2O gas-barrier cuff made of a special material].
    Kitamura A, Yamada K, Ishihara Y, Ogawa R.
    Masui; 1993 Jun; 42(6):826-30. PubMed ID: 8320798
    [Abstract] [Full Text] [Related]

  • 8. Preventive measure against nitrous oxide induced volume and pressure changes of endotracheal tube cuffs.
    Konchigeri HN, Lee YE.
    Middle East J Anaesthesiol; 1979 Oct; 5(5):369-73. PubMed ID: 542139
    [Abstract] [Full Text] [Related]

  • 9. Does sealing endotracheal tube cuff pressure diminish the frequency of postoperative laryngotracheal complaints after nitrous oxide anesthesia?
    Braz JR, Volney A, Navarro LH, Braz LG, Nakamura G.
    J Clin Anesth; 2004 Aug; 16(5):320-5. PubMed ID: 15374551
    [Abstract] [Full Text] [Related]

  • 10. [Decreased pressure of endotracheal tube cuff in general anesthesia without nitrous oxide].
    Komatsu H, Mitsuhata H, Hasegawa J, Matsumoto S.
    Masui; 1993 Jun; 42(6):831-4. PubMed ID: 8320799
    [Abstract] [Full Text] [Related]

  • 11. [Monitoring of cuff pressure in double-lumen endotracheal tubes during anesthesia for thoracic surgery].
    Pfaender M, Casetti PG, Battisti D, Azzolini M, Gasperotti G, Gazzini I, Rainer W.
    Minerva Anestesiol; 1994 Mar; 60(3):123-7. PubMed ID: 8090302
    [Abstract] [Full Text] [Related]

  • 12. Profile soft-seal cuff, a new endotracheal tube, effectively inhibits an increase in the cuff pressure through high compliance rather than low diffusion of nitrous oxide.
    Karasawa F, Mori T, Okuda T, Satoh T.
    Anesth Analg; 2001 Jan; 92(1):140-4. PubMed ID: 11133616
    [Abstract] [Full Text] [Related]

  • 13. Nitrous oxide use and endotracheal tube rupture.
    Mosby EL, Schelkun PM, Vincent SK.
    Anesth Prog; 1988 Jan; 35(1):14-6. PubMed ID: 3422793
    [Abstract] [Full Text] [Related]

  • 14. [Changes in intracuff pressure of endotracheal tubes permeable or resistant to nitrous oxide and incidence of postoperative sore throat].
    Sato K, Tanaka M, Nishikawa T.
    Masui; 2004 Jul; 53(7):767-71. PubMed ID: 15298243
    [Abstract] [Full Text] [Related]

  • 15. The Microcuff tube allows a longer time interval until unsafe cuff pressures are reached in children.
    Dullenkopf A, Gerber A, Weiss M.
    Can J Anaesth; 2004 Dec; 51(10):997-1001. PubMed ID: 15574550
    [Abstract] [Full Text] [Related]

  • 16. The TaperGuard™ endotracheal tube intracuff pressure increase is less than that of the Hi-Lo™ tube during nitrous oxide exposure: a model trachea study.
    Tsuboi S, Miyashita T, Yamaguchi Y, Yamamoto Y, Sakamaki K, Goto T.
    Anesth Analg; 2013 Mar; 116(3):609-12. PubMed ID: 23400983
    [Abstract] [Full Text] [Related]

  • 17. [Variation in the intracuff pressure of the tracheal tube during general anesthesia without nitrous oxide--the comparison of gas-barrier cuff and conventional "high-volume, low-pressure" cuff].
    Ohtsubo T, Ohishi S, Sakio H, Umezono Y.
    Masui; 2002 Jul; 51(7):750-4. PubMed ID: 12166280
    [Abstract] [Full Text] [Related]

  • 18. Comparison of air-sealing characteristics of tapered- vs. cylindrical-shaped high-volume, low-pressure tube cuffs.
    Madjdpour C, Mauch J, Dave MH, Spielmann N, Weiss M.
    Acta Anaesthesiol Scand; 2012 Feb; 56(2):230-5. PubMed ID: 22091784
    [Abstract] [Full Text] [Related]

  • 19. Deflationary phenomenon of the nitrous oxide-filled endotracheal tube cuff after cessation of nitrous oxide administration.
    Karasawa F, Mori T, Kawatani Y, Ohshima T, Satoh T.
    Anesth Analg; 2001 Jan; 92(1):145-8. PubMed ID: 11133617
    [Abstract] [Full Text] [Related]

  • 20. Rediffusion of nitrous oxide prevents increases in endotracheal tube cuff pressure.
    Fill DM, Dosch MP, Bruni MR.
    AANA J; 1994 Feb; 62(1):77-81. PubMed ID: 8122493
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 8.