These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
175 related items for PubMed ID: 7435383
1. Chronic intravascular hemolysis after aortic valve replacement with Ionescu-Shiley xenograft: comparative study with Bjork-Shiley prosthesis. Febres-Roman PR, Bourg WC, Crone RA, Davis RC, Williams TH. Am J Cardiol; 1980 Nov; 46(5):735-8. PubMed ID: 7435383 [Abstract] [Full Text] [Related]
2. Evaluation of intravascular hemolysis by haptoglobin administration after prosthetic valve replacement. Shioi K, Nagata Y, Mase T, Aoyama T, Katoh S, Tsuchioka H. Jpn Circ J; 1993 Apr; 57(4):322-7. PubMed ID: 8497113 [Abstract] [Full Text] [Related]
3. Chronic haemolysis following combined mitral and aortic valve replacement. A randomized study between the Björk-Shiley and Lillehei-Kaster disc valve prostheses. Nitter-Hauge S. Scand J Thorac Cardiovasc Surg; 1979 Apr; 13(2):97-101. PubMed ID: 472679 [Abstract] [Full Text] [Related]
4. Haemolysis after mitral valve replacement with the Björk-Shiley and the Lillehei-Kaster disc valve prosthesis. Nitter-Hauge S. Br Heart J; 1976 Sep; 38(9):977-80. PubMed ID: 971382 [Abstract] [Full Text] [Related]
5. [Effect of valve type and valve function on chronic intravascular hemolysis after alloprosthetic mitral and aortic valve replacement]. Horstkotte D, Aul C, Seipel L, Körfer R, Budde T, Schulte HD, Bircks W, Loogen F. Z Kardiol; 1983 Feb; 72(2):119-31. PubMed ID: 6845808 [Abstract] [Full Text] [Related]
6. Intravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis. Falk RH, Mackinnon J, Wainscoat J, Melikian V, Bignell AH. Thorax; 1979 Dec; 34(6):746-8. PubMed ID: 542913 [Abstract] [Full Text] [Related]
7. Chronic hemolysis following mitral valve replacement. A comparative study of the Björk-Shiley, composite-seat Starr-Edwards, and frame-mounted aortic homograft valves. Ahmad R, Manohitharajah SM, Deverall PB, Watson DA. J Thorac Cardiovasc Surg; 1976 Feb; 71(2):212-7. PubMed ID: 1246146 [Abstract] [Full Text] [Related]
15. Haematological evaluation of the Björk-Shiley tilting disc valve prosthesis in isolated aortic valvular disease. Björk VO, Henze A, Carlström A. Scand J Thorac Cardiovasc Surg; 1974 Apr; 8(1):12-22. PubMed ID: 4831280 [No Abstract] [Full Text] [Related]
16. [Chronic intravascular hemolysis following mitral valve replacement with Björk-Shiley, Lillehei-Kaster, and Starr-Edwards prosthesis]. Horstkotte D, Haerten K, Leuner C, Pottgen W, Kindler U, Loogen F. Z Kardiol; 1978 Sep; 67(9):629-36. PubMed ID: 716536 [No Abstract] [Full Text] [Related]
17. Aortic valve replacement with the Hancock standard, Björk-Shiley, and Lillehei-Kaster prostheses. A comparison based on follow-up from 1 to 15 years. Milano AD, Bortolotti U, Mazzucco A, Guerra F, Magni A, Gallucci V. J Thorac Cardiovasc Surg; 1989 Jul; 98(1):37-47. PubMed ID: 2739424 [Abstract] [Full Text] [Related]
18. Rest and exercise hemodynamics following aortic valve replacement. A comparison between 19 and 21 mm Ionescu-Shiley pericardial and Carpentier-Edwards porcine valves. Bove EL, Marvasti MA, Potts JL, Reger MJ, Zamora JL, Eich RH, Parker FB. J Thorac Cardiovasc Surg; 1985 Nov; 90(5):750-5. PubMed ID: 4058047 [Abstract] [Full Text] [Related]
19. Symptomatic anaemia 17 years after double valve replacement. Wong MH, Chee KH, Azman W. Singapore Med J; 2009 Oct; 50(10):e362-4. PubMed ID: 19907876 [Abstract] [Full Text] [Related]