These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
164 related items for PubMed ID: 7616784
1. Comparative analysis of power-line interference between two- or three-electrode biopotential amplifiers. Wood DE, Ewins DJ, Balachandran W. Med Biol Eng Comput; 1995 Jan; 33(1):63-8. PubMed ID: 7616784 [Abstract] [Full Text] [Related]
3. Double-differential recording and AGC using microcontrolled variable gain ASIC. Rieger R, Deng SL. IEEE Trans Neural Syst Rehabil Eng; 2013 Jan; 21(1):47-54. PubMed ID: 22929480 [Abstract] [Full Text] [Related]
11. High-quality biopotential acquisition without a reference electrode: power-line interference reduction by adaptive impedance balancing in a mixed analog-digital design. Dobrev DP, Neycheva TD. Med Biol Eng Comput; 2022 Jun; 60(6):1801-1814. PubMed ID: 35505176 [Abstract] [Full Text] [Related]
12. A multichannel EEG acquisition scheme based on single ended amplifiers and digital DRL. Haberman MA, Spinelli EM. IEEE Trans Biomed Circuits Syst; 2012 Dec; 6(6):614-8. PubMed ID: 23853262 [Abstract] [Full Text] [Related]
13. A Two-Wired Ultra-High Input Impedance Active Electrode. Guerrero FN, Spinelli EM. IEEE Trans Biomed Circuits Syst; 2018 Apr; 12(2):437-445. PubMed ID: 29570069 [Abstract] [Full Text] [Related]
14. Two-electrode-pair electrocardiogram with no common ground between two pairs. Hsieh HY, Luo CH, Ye JW, Tai CC. Rev Sci Instrum; 2019 Nov 01; 90(11):114703. PubMed ID: 31779454 [Abstract] [Full Text] [Related]
15. Monitoring instrumentation. Isolated inputs, electrosurgery filtering, burns protection: what does it mean? Uyttendaele K, Grobstein S, Svetz P. Acta Anaesthesiol Belg; 1978 Nov 01; 29(3):317-30. PubMed ID: 751436 [Abstract] [Full Text] [Related]
16. Simple two-electrode biosignal amplifier. Dobrev D, Neycheva T, Mudrov N. Med Biol Eng Comput; 2005 Nov 01; 43(6):725-30. PubMed ID: 16594298 [Abstract] [Full Text] [Related]
17. Can driven-right-leg circuits increase interference in ECG amplifiers? Gomez-Clapers J, Serrano-Finetti E, Casanella R, Pallas-Areny R. Annu Int Conf IEEE Eng Med Biol Soc; 2011 Nov 01; 2011():4780-3. PubMed ID: 22255407 [Abstract] [Full Text] [Related]
18. A 0.09 μW low power front-end biopotential amplifier for biosignal recording. Tseng Y, Ho Y, Kao S, Su C. IEEE Trans Biomed Circuits Syst; 2012 Oct 01; 6(5):508-16. PubMed ID: 23853237 [Abstract] [Full Text] [Related]
19. On the reduction of interference due to common mode voltage in two-electrode biopotential amplifiers. Pallás-Areny R. IEEE Trans Biomed Eng; 1986 Nov 01; 33(11):1043-6. PubMed ID: 3793125 [No Abstract] [Full Text] [Related]
20. A biosignal instrumentation system using capacitive coupling for power and signal isolation. Piipponen KV, Sepponen R, Eskelinen P. IEEE Trans Biomed Eng; 2007 Oct 01; 54(10):1822-8. PubMed ID: 17926680 [Abstract] [Full Text] [Related] Page: [Next] [New Search]