These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
90 related items for PubMed ID: 7626568
1. Longitudinal study of posterior subcapsular opacities using the National Eye Institute computer planimetry system. Lopez ML, Freidlin V, Datiles MB. Br J Ophthalmol; 1995 Jun; 79(6):535-40. PubMed ID: 7626568 [Abstract] [Full Text] [Related]
2. A longitudinal study of cortical cataracts using retroillumination photographs. Datiles MB, Lasa MS, Freidlin V. Curr Eye Res; 1996 Jan; 15(1):53-61. PubMed ID: 8631204 [Abstract] [Full Text] [Related]
3. Study of nuclear cataract progression using the National Eye Institute Scheimpflug system. Datiles MB, Magno BV, Freidlin V. Br J Ophthalmol; 1995 Jun; 79(6):527-34. PubMed ID: 7626567 [Abstract] [Full Text] [Related]
9. Measured changes in cataract over six months: sensitivity of the Nidek EAS-1000. Foo KP, Maclean H. Ophthalmic Res; 1996 Sep 05; 28 Suppl 2():32-6. PubMed ID: 8883087 [Abstract] [Full Text] [Related]
10. [The application of digital photography with retroillumination for lens in cataract study]. Li JJ, Xu L, Sun BC, Chen YJ, Ma K. Zhonghua Yan Ke Za Zhi; 2003 May 05; 39(5):278-82. PubMed ID: 12892603 [Abstract] [Full Text] [Related]
11. Incidence and progression of cortical and posterior subcapsular opacities: the Longitudinal Study of Cataract. The LSC Group. Leske MC, Chylack LT, He Q, Wu SY, Schoenfeld E, Friend J, Wolfe J. Ophthalmology; 1997 Dec 05; 104(12):1987-93. PubMed ID: 9400756 [Abstract] [Full Text] [Related]
13. Subjective (LOCS II) versus objective (BGS) measures of cortical and subcapsular cataracts in retroillumination photographs. Khu PM, Kashiwagi T. Ophthalmic Res; 1990 Dec 05; 22 Suppl 1():68-70. PubMed ID: 2388754 [Abstract] [Full Text] [Related]
15. The comparability of estimates of retroilluminated lens opacities as judged from film-based and digital imaging. Klein BE, Klein R, Hall ER, Lee KE, Jensen K. Am J Ophthalmol; 2004 Oct 05; 138(4):668-70. PubMed ID: 15488807 [Abstract] [Full Text] [Related]
16. Application of digital image analysis in cataract retroillumination photography. Mayer H. Ophthalmic Res; 1987 Oct 05; 19(5):266-70. PubMed ID: 2830568 [Abstract] [Full Text] [Related]
17. Validation of methods for the assessment of cataract progression in the Roche European-American Anticataract Trial (REACT). Chylack LT, Wolfe JK, Friend J, Tung W, Singer DM, Brown NP, Hurst MA, Köpcke W, Schalch W. Ophthalmic Epidemiol; 1995 Jun 05; 2(2):59-75. PubMed ID: 7585237 [Abstract] [Full Text] [Related]
18. Dynamic nature of posterior subcapsular cataract. Adrien Shun-Shin G, Brown NP, Bron AJ, Sparrow JM. Br J Ophthalmol; 1989 Jul 05; 73(7):522-7. PubMed ID: 2757992 [Abstract] [Full Text] [Related]
19. Evaluation of photographic methods for documentation of lens opacities. Lee JA, Taylor HR. Invest Ophthalmol Vis Sci; 1990 Jun 05; 31(6):1191-3. PubMed ID: 2354922 [Abstract] [Full Text] [Related]
20. Morphology of and visual performance with posterior subcapsular cataract. Vasavada AR, Mamidipudi PR, Sharma PS. J Cataract Refract Surg; 2004 Oct 05; 30(10):2097-104. PubMed ID: 15474821 [Abstract] [Full Text] [Related] Page: [Next] [New Search]