These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Estimation of 241Am and 239Pu activity embedded in the tissue using portable planar HPGe detector. Murugan M, Ponraj S, Ramasamy M, Durairaj P, Balasubramanian V. Radiat Prot Dosimetry; 2024 Jun 03; 200(8):721-738. PubMed ID: 38690853 [Abstract] [Full Text] [Related]
6. Concentrations of plutonium and americium in plankton from the western Mediterranean Sea. Sanchez-Cabeza JA, Merino J, Masqué P, Mitchell PI, Vintró LL, Schell WR, Cross L, Calbet A. Sci Total Environ; 2003 Jul 20; 311(1-3):233-45. PubMed ID: 12826395 [Abstract] [Full Text] [Related]
7. Distribution of plutonium and americium in the body 5 years after an exposure via contaminated punctured wound. Lagerquist CR, Hammond SE, Hyltron DB. Health Phys; 1972 Jun 20; 22(6):921-4. PubMed ID: 5084028 [No Abstract] [Full Text] [Related]
8. A low-energy photon detector for the radioassay of Pu or Am in biological samples. Guilmette RA. Health Phys; 1986 Dec 20; 51(6):797-803. PubMed ID: 3781853 [No Abstract] [Full Text] [Related]
10. Origin and release date assessment of environmental plutonium by isotopic composition. Varga Z. Anal Bioanal Chem; 2007 Oct 20; 389(3):725-32. PubMed ID: 17554528 [Abstract] [Full Text] [Related]
11. [Rapid analysis of the radionuclides plutonium and americium-241 in soils]. Egorov AV, Klochkova NV. Gig Sanit; 2009 Oct 20; (3):64-6. PubMed ID: 19642559 [Abstract] [Full Text] [Related]
13. Determination of the ratios of 239Pu and 240Pu to 241Am for nuclear weapons test sites in Australia. Burns PA, Cooper MB, Johnston PN, Martin LJ, Williams GA. Health Phys; 1994 Sep 20; 67(3):226-32. PubMed ID: 8056588 [Abstract] [Full Text] [Related]
14. Development of a rapid technique for sequential separation of plutonium/americium in nasal swab using solvent extraction and liquid scintillation spectrometry. Panda S, Reddy PJ, Yadav JR, Sawant PD, Kulkarni MS. Appl Radiat Isot; 2022 Aug 20; 186():110297. PubMed ID: 35623136 [Abstract] [Full Text] [Related]
16. YAP:CE SCINTILLATOR APPLICATION FOR 241AM COUNTING IN WOUND INJURY. Fojtík P, Rovenská V. Radiat Prot Dosimetry; 2022 Aug 22; 198(9-11):586-589. PubMed ID: 36005964 [Abstract] [Full Text] [Related]
17. The determination of plutonium to americium ratios in biological specimens. BNWL-714. Jones YM, Jackson PO. BNWL Rep; 1968 May 22; ():3.11-3+. PubMed ID: 5307065 [No Abstract] [Full Text] [Related]
18. Body counter evaluations of plutonium exposures. Boss MR, Mann JR. Health Phys; 1967 Mar 22; 13(3):259-66. PubMed ID: 4962185 [No Abstract] [Full Text] [Related]