These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
23. CFD and PTV steady flow investigation in an anatomically accurate abdominal aortic aneurysm. Boutsianis E, Guala M, Olgac U, Wildermuth S, Hoyer K, Ventikos Y, Poulikakos D. J Biomech Eng; 2009 Jan; 131(1):011008. PubMed ID: 19045924 [Abstract] [Full Text] [Related]
24. Derivation of shear rates from near-wall LDA measurements under steady and pulsatile flow conditions. Fatemi RS, Rittgers SE. J Biomech Eng; 1994 Aug; 116(3):361-8. PubMed ID: 7799640 [Abstract] [Full Text] [Related]
30. Investigation of pulsatile flowfield in healthy thoracic aorta models. Wen CY, Yang AS, Tseng LY, Chai JW. Ann Biomed Eng; 2010 Feb; 38(2):391-402. PubMed ID: 19890715 [Abstract] [Full Text] [Related]
31. The effect of pulsatile frequency on wall shear in a compliant cast of a human aortic bifurcation. Kuban BD, Friedman MH. J Biomech Eng; 1995 May; 117(2):219-23. PubMed ID: 7666659 [Abstract] [Full Text] [Related]
33. 4D model of hemodynamics in the abdominal aorta. Zbicinski I, Veshkina N, Stefańczyk L. Biomed Mater Eng; 2015 May; 26 Suppl 1():S257-64. PubMed ID: 26406010 [Abstract] [Full Text] [Related]
34. Flow and wall shear stress characterization after endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model. Boersen JT, Groot Jebbink E, Versluis M, Slump CH, Ku DN, de Vries JPM, Reijnen MMPJ. J Vasc Surg; 2017 Dec; 66(6):1844-1853. PubMed ID: 28285931 [Abstract] [Full Text] [Related]
37. Asymmetric radial expansion and contraction of rat carotid artery observed using a high-resolution ultrasound imaging system. Nam KH, Bok TH, Jin C, Paeng DG. Ultrasonics; 2014 Jan; 54(1):233-40. PubMed ID: 23664377 [Abstract] [Full Text] [Related]
38. Hemodynamics simulation and identification of susceptible sites of atherosclerotic lesion formation in a model abdominal aorta. Buchanan JR, Kleinstreuer C, Hyun S, Truskey GA. J Biomech; 2003 Aug; 36(8):1185-96. PubMed ID: 12831745 [Abstract] [Full Text] [Related]
39. Numerical simulation of pulsating flow in the aortic arch. Engelbrecht H, Steinmann CM, Pretorius L. S Afr Med J; 1998 Feb; 88 Suppl 1():C40-3. PubMed ID: 9542494 [Abstract] [Full Text] [Related]
40. Large curvature effect on pulsatile entrance flow in a curved tube: model experiment simulating blood flow in an aortic arch. Naruse T, Tanishita K. J Biomech Eng; 1996 May; 118(2):180-6. PubMed ID: 8738782 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]