These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
169 related items for PubMed ID: 7839778
1. Spinal anaesthesia with 29 gauge Quincke point needles and post dural puncture headache in 2,378 patients. Dittmann M, Schaefer HG, Renkl F, Greve I. Acta Anaesthesiol Scand; 1994 Oct; 38(7):691-3. PubMed ID: 7839778 [Abstract] [Full Text] [Related]
2. [The effect of needle type and immobilization on postspinal headache]. Hafer J, Rupp D, Wollbrück M, Engel J, Hempelmann G. Anaesthesist; 1997 Oct; 46(10):860-6. PubMed ID: 9424969 [Abstract] [Full Text] [Related]
3. Role of needle gauge and tip configuration in the production of lumbar puncture headache. Lambert DH, Hurley RJ, Hertwig L, Datta S. Reg Anesth; 1997 Oct; 22(1):66-72. PubMed ID: 9010949 [Abstract] [Full Text] [Related]
4. Post dural puncture headache in cesarean section: comparison of 25-gauge Whitacre with 25- and 26-gauge Quincke needles. Hwang JJ, Ho ST, Wang JJ, Liu HS. Acta Anaesthesiol Sin; 1997 Mar; 35(1):33-7. PubMed ID: 9212479 [Abstract] [Full Text] [Related]
5. Grading of severity of postdural puncture headache after 27-gauge Quincke and Whitacre needles. Corbey MP, Bach AB, Lech K, Frørup AM. Acta Anaesthesiol Scand; 1997 Jun; 41(6):779-84. PubMed ID: 9241342 [Abstract] [Full Text] [Related]
6. Postdural puncture headache: a randomized prospective comparison of the 24 gauge Sprotte and the 27 gauge Quincke needles in young patients. Wiesel S, Tessler MJ, Easdown LJ. Can J Anaesth; 1993 Jul; 40(7):607-11. PubMed ID: 8403134 [Abstract] [Full Text] [Related]
7. Postdural puncture headache and back pain after spinal anesthesia with 27-gauge Quincke and 26-gauge Atraucan needles. Schultz AM, Ulbing S, Kaider A, Lehofer F. Reg Anesth; 1996 Jul; 21(5):461-4. PubMed ID: 8896009 [Abstract] [Full Text] [Related]
8. Comparison of Sprotte and Quincke needles with respect to post dural puncture headache and backache. Tarkkila PJ, Heine H, Tervo RR. Reg Anesth; 1992 Jul; 17(5):283-7. PubMed ID: 1419942 [Abstract] [Full Text] [Related]
9. PDPH in obstetric anesthesia: comparison of 24-gauge Sprotte and 25-gauge Quincke needles and effect of subarachnoid administration of fentanyl. Devcic A, Sprung J, Patel S, Kettler R, Maitra-D'Cruze A. Reg Anesth; 1993 Jul; 18(4):222-5. PubMed ID: 8398955 [Abstract] [Full Text] [Related]
10. Comparison of post-dural puncture headache and low back pain between 23 and 25 gauge Quincke spinal needles in patients over 60 years: randomized, double-blind controlled trial. Kim M, Yoon H. Int J Nurs Stud; 2011 Nov; 48(11):1315-22. PubMed ID: 21561619 [Abstract] [Full Text] [Related]
11. Postdural puncture headache: a randomized comparison of five spinal needles in obstetric patients. Vallejo MC, Mandell GL, Sabo DP, Ramanathan S. Anesth Analg; 2000 Oct; 91(4):916-20. PubMed ID: 11004048 [Abstract] [Full Text] [Related]
12. Postdural puncture headache after spinal anaesthesia in young orthopaedic outpatients using 27-g needles. Despond O, Meuret P, Hemmings G. Can J Anaesth; 1998 Nov; 45(11):1106-9. PubMed ID: 10021962 [Abstract] [Full Text] [Related]
13. Comparison of 27-gauge (0.41-mm) Whitacre and Quincke spinal needles with respect to post-dural puncture headache and non-dural puncture headache. Santanen U, Rautoma P, Luurila H, Erkola O, Pere P. Acta Anaesthesiol Scand; 2004 Apr; 48(4):474-9. PubMed ID: 15025611 [Abstract] [Full Text] [Related]
14. The Sprotte needle and post dural puncture headache following caesarean section. Ross AW, Greenhalgh C, McGlade DP, Balson IG, Chester SC, Hutchinson RC, Ashley JE. Anaesth Intensive Care; 1993 Jun; 21(3):280-3. PubMed ID: 8342755 [Abstract] [Full Text] [Related]
15. Post-dural puncture headache in young orthopaedic in-patients: comparison of a 0.33 mm (29-gauge) Quincke-type with a 0.7 mm (22-gauge) Whitacre spinal needle in 200 patients. Lynch J, Arhelger S, Krings-Ernst I. Acta Anaesthesiol Scand; 1992 Jan; 36(1):58-61. PubMed ID: 1539481 [Abstract] [Full Text] [Related]
16. Postdural puncture headache and transient neurologic symptoms in children after spinal anaesthesia using cutting and pencil point paediatric spinal needles. Kokki H, Hendolin H, Turunen M. Acta Anaesthesiol Scand; 1998 Oct; 42(9):1076-82. PubMed ID: 9809091 [Abstract] [Full Text] [Related]
17. Post dural puncture headache after spinal anaesthesia for caesarean section: a comparison of 25 g Quincke, 27 g Quincke and 27 g Whitacre spinal needles. Shaikh JM, Memon A, Memon MA, Khan M. J Ayub Med Coll Abbottabad; 2008 Oct; 20(3):10-3. PubMed ID: 19610505 [Abstract] [Full Text] [Related]
18. [Comparison of two 27-G-caliber needles for spinal anesthesia. Study of 1,555 patients]. de Diego Fernández R, Tisner Madrid ML, Cabrerizo Torrente P, Sanjoaquín Mur T. Rev Esp Anestesiol Reanim; 2003 Apr; 50(4):182-7. PubMed ID: 12825306 [Abstract] [Full Text] [Related]
19. Incidence of post-dural puncture headache with 25-gauge Quincke spinal needle. Wu YW, Hui YL, Tan PP. Ma Zui Xue Za Zhi; 1991 Mar; 29(1):538-41. PubMed ID: 1758245 [Abstract] [Full Text] [Related]
20. Sprotte needle for obstetric anesthesia: decreased incidence of post dural puncture headache. Ross BK, Chadwick HS, Mancuso JJ, Benedetti C. Reg Anesth; 1992 Mar; 17(1):29-33. PubMed ID: 1599891 [Abstract] [Full Text] [Related] Page: [Next] [New Search]