These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Frequency-domain digital filtering techniques for the removal of powerline noise with application to the electrocardiogram. Ferdjallah M, Barr RE. Comput Biomed Res; 1990 Oct; 23(5):473-89. PubMed ID: 2225791 [Abstract] [Full Text] [Related]
5. A novel application of the S-transform in removing powerline interference from biomedical signals. Huang CC, Liang SF, Young MS, Shaw FZ. Physiol Meas; 2009 Jan; 30(1):13-27. PubMed ID: 19039164 [Abstract] [Full Text] [Related]
6. Adaptive noise removal from biomedical signals using warped polynomials. Philips W. IEEE Trans Biomed Eng; 1996 May; 43(5):480-92. PubMed ID: 8849461 [Abstract] [Full Text] [Related]
7. [Research of adaptive notch filter based on QRD-LS algorithm for power line interference in ECG]. Wang S, Dong J, Guan X. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Oct; 25(5):1044-7. PubMed ID: 19024443 [Abstract] [Full Text] [Related]
8. Elimination of AC interference in electrocardiogram using IIR notch filter with transient suppression. Pei SC, Tseng CC. IEEE Trans Biomed Eng; 1995 Nov; 42(11):1128-32. PubMed ID: 7498917 [Abstract] [Full Text] [Related]
9. Removing ECG noise from surface EMG signals using adaptive filtering. Lu G, Brittain JS, Holland P, Yianni J, Green AL, Stein JF, Aziz TZ, Wang S. Neurosci Lett; 2009 Oct 02; 462(1):14-9. PubMed ID: 19559751 [Abstract] [Full Text] [Related]
10. An improved adaptive power line interference canceller for electrocardiography. Martens SM, Mischi M, Oei SG, Bergmans JW. IEEE Trans Biomed Eng; 2006 Nov 02; 53(11):2220-31. PubMed ID: 17073327 [Abstract] [Full Text] [Related]
11. Integrating the ECG power-line interference removal methods with rule-based system. Kumaravel N, Senthil A, Sridhar KS, Nithiyanandam N. Biomed Sci Instrum; 1995 Nov 02; 31():115-20. PubMed ID: 7654947 [Abstract] [Full Text] [Related]
12. [The application of adaptive algorithm and wavelet transform in the filtering of ECG signal]. Zhang J, Zhang G, Dai G. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Oct 02; 23(5):977-80. PubMed ID: 17121335 [Abstract] [Full Text] [Related]
18. Filtering and thresholding the analytic signal envelope in order to improve peak and spike noise reduction in EEG signals. Melia U, Clariá F, Vallverdú M, Caminal P. Med Eng Phys; 2014 Apr 02; 36(4):547-53. PubMed ID: 24365255 [Abstract] [Full Text] [Related]
19. Constrained RLS algorithm for narrow band interference rejection from EEG signal during CES. Sezer O, Ferdjallah M. Conf Proc IEEE Eng Med Biol Soc; 2004 Apr 02; 2006():494-7. PubMed ID: 17271721 [Abstract] [Full Text] [Related]
20. Event-synchronous cancellation of the heart interference in biomedical signals. Strobach P, Abraham-Fuchs K, Härer W. IEEE Trans Biomed Eng; 1994 Apr 02; 41(4):343-50. PubMed ID: 8063300 [Abstract] [Full Text] [Related] Page: [Next] [New Search]