These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


148 related items for PubMed ID: 7970116

  • 1. Influence of dialyser clearance measurement accuracy on haemodialysis prescription based on Kt/V.
    Zehnder C, Blumberg A.
    Nephrol Dial Transplant; 1994; 9(7):753-7. PubMed ID: 7970116
    [Abstract] [Full Text] [Related]

  • 2. Causes of impaired delivery of hemodialysis prescription.
    Fourtounas C, Kopelias I, Paraskevopoulos A, Dimitriadis G, Agroyannis B.
    Artif Organs; 2006 Nov; 30(11):878-81. PubMed ID: 17062111
    [Abstract] [Full Text] [Related]

  • 3. In vivo effects of dialysate flow rate on Kt/V in maintenance hemodialysis patients.
    Hauk M, Kuhlmann MK, Riegel W, Köhler H.
    Am J Kidney Dis; 2000 Jan; 35(1):105-11. PubMed ID: 10620551
    [Abstract] [Full Text] [Related]

  • 4. Increasing dialysate flow rate increases dialyzer urea clearance and dialysis efficiency: an in vivo study.
    Azar AT.
    Saudi J Kidney Dis Transpl; 2009 Nov; 20(6):1023-9. PubMed ID: 19861865
    [Abstract] [Full Text] [Related]

  • 5. Effects of different sampling methods for measurement of post dialysis blood urea nitrogen on urea kinetic modeling derived parameters in patients undergoing long-term hemodialysis.
    Lai YH, Guh JY, Chen HC, Tsai JH.
    ASAIO J; 1995 Nov; 41(2):211-5. PubMed ID: 7640430
    [Abstract] [Full Text] [Related]

  • 6.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 7. Hemodialysis blood access flow rates can be estimated accurately from on-line dialysate urea measurements and the knowledge of effective dialyzer urea clearance.
    Lindsay RM, Sternby J, Olde B, Persson R, Thatcher ME, Sargent K.
    Clin J Am Soc Nephrol; 2006 Sep; 1(5):960-4. PubMed ID: 17699313
    [Abstract] [Full Text] [Related]

  • 8. Assessment of the length of each hemodialysis session by on-line dialysate urea monitoring.
    Hernandez-Herrera G, Martin-Malo A, Rodriguez M, Aljama P.
    Nephron; 2001 Sep; 89(1):37-42. PubMed ID: 11528230
    [Abstract] [Full Text] [Related]

  • 9. A comparison of methods for determining urea distribution volume for routine use in on-line monitoring of haemodialysis adequacy.
    Lindley EJ, Chamney PW, Wuepper A, Ingles H, Tattersall JE, Will EJ.
    Nephrol Dial Transplant; 2009 Jan; 24(1):211-6. PubMed ID: 18697799
    [Abstract] [Full Text] [Related]

  • 10. Dialysis dose (Kt/V) and clearance variation sensitivity using measurement of ultraviolet-absorbance (on-line), blood urea, dialysate urea and ionic dialysance.
    Uhlin F, Fridolin I, Magnusson M, Lindberg LG.
    Nephrol Dial Transplant; 2006 Aug; 21(8):2225-31. PubMed ID: 16611681
    [Abstract] [Full Text] [Related]

  • 11. Adequacy of haemodialysis and nutrition in maintenance haemodialysis patients: clinical evaluation of a new on-line urea monitor.
    Chauveau P, Naret C, Puget J, Zins B, Poignet JL.
    Nephrol Dial Transplant; 1996 Aug; 11(8):1568-73. PubMed ID: 8856213
    [Abstract] [Full Text] [Related]

  • 12. Blood urea levels 30 minutes before the end of dialysis are equivalent to equilibrated blood urea.
    Bhaskaran S, Tobe S, Saiphoo C, Moldoveanu A, Raj DS, Manuel MA.
    ASAIO J; 1997 Aug; 43(5):M759-62. PubMed ID: 9360148
    [Abstract] [Full Text] [Related]

  • 13. Use of ionic dialysance to calculate Kt/V in pediatric hemodialysis.
    Marsenic O, Booker K, Studnicka K, Wilson D, Beck A, Swanson T, Henry D, Turman M.
    Hemodial Int; 2011 Oct; 15 Suppl 1():S2-8. PubMed ID: 22093596
    [Abstract] [Full Text] [Related]

  • 14.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 15. [Kt/V as a measure of hemodialysis adequacy].
    Kovacić V.
    Lijec Vjesn; 2003 Oct; 125(7-8):188-91. PubMed ID: 14692093
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17. Comparison of high-efficiency and standard haemodialysis providing equal urea clearances by partial and total dialysate quantification.
    Mactier RA, Madi AM, Allam BF.
    Nephrol Dial Transplant; 1997 Jun; 12(6):1182-6. PubMed ID: 9198048
    [Abstract] [Full Text] [Related]

  • 18. Higher Kt/V is needed for adequate dialysis if the treatment time is reduced. Insights from a blood flow distribution model.
    Haraldsson B.
    Nephrol Dial Transplant; 1995 Oct; 10(10):1845-51. PubMed ID: 8592592
    [Abstract] [Full Text] [Related]

  • 19. Mathematical analysis of urea rebound in long-term hemodialysis patients.
    Ookawara S, Suzuki M, Saitou M, Tabei K.
    Ther Apher Dial; 2005 Apr; 9(2):167-72. PubMed ID: 15828930
    [Abstract] [Full Text] [Related]

  • 20. Comparison of standard and artificial neural network estimators of hemodialysis adequacy.
    Fernández EA, Valtuille R, Rodriguez Presedo J, Willshaw P.
    Artif Organs; 2005 Feb; 29(2):159-65. PubMed ID: 15670285
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 8.