These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
207 related items for PubMed ID: 7989803
1. [Aortic dissection with giant pseudoaneurysm as a rare late complication of aortic valve replacement--a case report]. Seki K, Abe T, Kuribayashi R, Sekine S, Shibata Y, Yamagishi I. Nihon Kyobu Geka Gakkai Zasshi; 1994 Sep; 42(9):1382-7. PubMed ID: 7989803 [Abstract] [Full Text] [Related]
2. [A case report of type A dissection of the aorta presenting as a superior vena cava syndrome 10 years after aortic valve replacement]. Murai N, Kaneko T, Obayashi T, Aizaki M, Ichikawa H. Kyobu Geka; 1997 Feb; 50(2):146-9. PubMed ID: 9028072 [Abstract] [Full Text] [Related]
3. [Aortic dissection (DeBakey type I) associated with pseudoaneurysm 21 years after aortic valve replacement; report of a case]. Nakajima M, Tsuchiya K, Kobayashi K, Amano H, Takizawa K. Kyobu Geka; 2004 Jul; 57(7):565-8. PubMed ID: 15285385 [Abstract] [Full Text] [Related]
4. [A repair of the aortic pseudoaneurysm after ascending aortic grafting in acute type A dissection--a case report]. Fukuda I, Ohuchi H, Matsuzaki K. Nihon Kyobu Geka Gakkai Zasshi; 1995 Apr; 43(4):502-5. PubMed ID: 7608601 [Abstract] [Full Text] [Related]
5. [Successful surgical treatment of intraoperative aortic dissection complicating aortic valve replacement]. Ozaki S, Toyama M, Kawase I, Horimi H. Nihon Kyobu Geka Gakkai Zasshi; 1996 Jul; 44(7):1022-6. PubMed ID: 8741569 [Abstract] [Full Text] [Related]
6. [A case report of successful management of intraoperative aortic dissection during aorta-coronary bypass and aortic valve replacement]. Murayama H, Murase M, Maeda M, Teranishi K, Sakurai H, Nishizawa T. Kyobu Geka; 1994 May; 47(5):368-72. PubMed ID: 8196240 [Abstract] [Full Text] [Related]
7. [A case of acute dissecting aortic aneurysm associated with congenital bicuspid aortic valve]. Hirai M, Takemura T, Ohno H, Furukawa H. Nihon Kyobu Geka Gakkai Zasshi; 1995 Mar; 43(3):335-9. PubMed ID: 7769339 [Abstract] [Full Text] [Related]
8. [Acute aortic dissection after aortic valve replacement]. Kohata S, Sugama M, Ogata T. Jpn J Thorac Cardiovasc Surg; 1998 Jan; 46(1):101-4. PubMed ID: 9513534 [Abstract] [Full Text] [Related]
9. [Acute type A aortic dissection, developed shortly after aortic valve replacement and coronary artery bypass grafting]. Nishimura O, Suzuki T, Hosoba S, Takashima N, Hiramatsu N, Kinoshita T, Kambara A, Matsubayashi K, Asai T. Kyobu Geka; 2010 Dec; 63(13):1141-4. PubMed ID: 21174664 [Abstract] [Full Text] [Related]
10. [Pseudoaneurysm after Bentall's procedure in acute aortic dissection type A: diagnosis using electron beam tomography]. Gulbins H, Becker C, Kilian E, Reichenspurner H, Reichart B. Z Kardiol; 2000 Mar; 89(3):195-8. PubMed ID: 10798275 [Abstract] [Full Text] [Related]
11. Late reoperations after acute aortic dissection repair: Single-center experience. Luciani N, De Geest R, Lauria G, Farina P, Luciani M, Glieca F, Massetti M. Asian Cardiovasc Thorac Ann; 2015 Sep; 23(7):787-94. PubMed ID: 25972294 [Abstract] [Full Text] [Related]
12. Rupture of aortic pseudoaneursym arising from a transverse aortotomy line 12 years following mechanical aortic valve replacement. Galvin SD, Ninan SB, Lau GB, Galvin IF. J Card Surg; 2010 Sep; 25(5):563-5. PubMed ID: 20546076 [Abstract] [Full Text] [Related]
13. Zone zero thoracic endovascular aortic repair: A proposed modification to the classification of landing zones. Roselli EE, Idrees JJ, Johnston DR, Eagleton MJ, Desai MY, Svensson LG. J Thorac Cardiovasc Surg; 2018 Apr; 155(4):1381-1389. PubMed ID: 29395197 [Abstract] [Full Text] [Related]
14. Outcomes of thoracic endovascular aortic repair in adult coarctation patients. Lala S, Scali ST, Feezor RJ, Chandrekashar S, Giles KA, Fatima J, Berceli SA, Back MR, Huber TS, Beaver TM, Beck AW. J Vasc Surg; 2018 Feb; 67(2):369-381.e2. PubMed ID: 28947226 [Abstract] [Full Text] [Related]
15. Percutaneous occlusion of the entry to a leaking false aneurysm after ascending aortic replacement for aortic dissection type A facilitating surgical repair. Henriques JP, Brutel de la Riviere A, Schepens MA, Ernst JM. Eur J Cardiothorac Surg; 1997 Feb; 11(2):381-3. PubMed ID: 9080172 [Abstract] [Full Text] [Related]
16. Repair of Chronic Aneurysmal Aortic Dissection Using a Stent Graft and an Amplatzer® Vascular Plug: A Case Study. Kanaoka Y, Ohki T, Ozawa H. Ann Vasc Surg; 2017 Feb; 39():288.e5-288.e12. PubMed ID: 27671450 [Abstract] [Full Text] [Related]
17. [The usefulness of transesophageal echocardiography in the follow-up of patients operated on for replacement of the ascending aorta with a tubular-valvular prosthesis (Cabrol's intervention)]. Morocutti G, Di Chiara A, Fontanelli A, Bernardi G, Gianfagna P, Frassani R, Morelli A, Puricelli C, Feruglio GA. G Ital Cardiol; 1995 Feb; 25(2):183-92. PubMed ID: 7642023 [Abstract] [Full Text] [Related]
18. [A case report of the dissecting aneurysm of ascending aorta, which was surmised to be developed after aortic valve replacement]. Nakano H, Hayashi K, Ootsuka G, Daimon M, Okamura H. Kyobu Geka; 2001 Oct; 54(11):977-80. PubMed ID: 11593739 [Abstract] [Full Text] [Related]
19. [Successful surgical treatment for type B aortic dissection with Marfan's syndrome after aortic root and mitral valve replacement: report of a case]. Ueno K, Kozuka Y, Kawauchi M, Tanaka O, Hirata K, Furuse A. Kyobu Geka; 1997 Oct; 50(11):983-8. PubMed ID: 9330527 [Abstract] [Full Text] [Related]
20. [A case report of ruptured pseudoaneurysm into the left lung after graft replacement of the descending thoracic aorta]. Koshino T, Kazui T, Tamiya Y, Fukada J, Koushima R, Abe T. Kyobu Geka; 1998 Feb; 51(2):120-4. PubMed ID: 9492461 [Abstract] [Full Text] [Related] Page: [Next] [New Search]