These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
984 related items for PubMed ID: 7998522
1. Staging urinary bladder cancer: value of T1-weighted three-dimensional magnetization prepared-rapid gradient-echo and two-dimensional spin-echo sequences. Barentsz JO, Jager G, Mugler JP, Oosterhof G, Peters H, van Erning LT, Ruijs SH. AJR Am J Roentgenol; 1995 Jan; 164(1):109-15. PubMed ID: 7998522 [Abstract] [Full Text] [Related]
2. Pelvic adenopathy in prostatic and urinary bladder carcinoma: MR imaging with a three-dimensional TI-weighted magnetization-prepared-rapid gradient-echo sequence. Jager GJ, Barentsz JO, Oosterhof GO, Witjes JA, Ruijs SJ. AJR Am J Roentgenol; 1996 Dec; 167(6):1503-7. PubMed ID: 8956585 [Abstract] [Full Text] [Related]
3. MR imaging of the inner ear and cerebellopontine angle: comparison of three-dimensional and two-dimensional sequences. Czerny C, Rand T, Gstoettner W, Woelfl G, Imhof H, Trattnig S. AJR Am J Roentgenol; 1998 Mar; 170(3):791-6. PubMed ID: 9490977 [Abstract] [Full Text] [Related]
4. Evaluation of malignant biliary obstruction: efficacy of fast multiplanar spoiled gradient-recalled MR imaging vs spin-echo MR imaging, CT, and cholangiography. Low RN, Sigeti JS, Francis IR, Weinman D, Bower B, Shimakawa A, Foo TK. AJR Am J Roentgenol; 1994 Feb; 162(2):315-23. PubMed ID: 8310918 [Abstract] [Full Text] [Related]
5. Fast multiplanar spoiled gradient-recalled imaging of the liver: pulse sequence optimization and comparison with spin-echo MR imaging. Low RN, Francis IR, Herfkens RJ, Jeffrey RB, Glazer GM, Foo TK, Shimakawa A, Pelc NJ. AJR Am J Roentgenol; 1993 Mar; 160(3):501-9. PubMed ID: 8381572 [Abstract] [Full Text] [Related]
6. Gadolinium-enhanced three-dimensional magnetization-prepared rapid gradient-echo (3D MP-RAGE) imaging is superior to spin-echo imaging in delineating brain metastases. Takeda T, Takeda A, Nagaoka T, Kunieda E, Takemasa K, Watanabe M, Hatou T, Oguro S, Katayama M. Acta Radiol; 2008 Dec; 49(10):1167-73. PubMed ID: 18979271 [Abstract] [Full Text] [Related]
7. MR imaging of head and neck tumors: comparison of T1-weighted contrast-enhanced fat-suppressed images with conventional T2-weighted and fast spin-echo T2-weighted images. Ross MR, Schomer DF, Chappell P, Enzmann DR. AJR Am J Roentgenol; 1994 Jul; 163(1):173-8. PubMed ID: 8010208 [Abstract] [Full Text] [Related]
8. Fast spin-echo MR images of the pelvis obtained with a phased-array coil: value in localizing and staging prostatic carcinoma. Kier R, Wain S, Troiano R. AJR Am J Roentgenol; 1993 Sep; 161(3):601-6. PubMed ID: 8352116 [Abstract] [Full Text] [Related]
9. Conspicuity of tumors of the head and neck on fat-suppressed MR images: T2-weighted fast-spin-echo versus contrast-enhanced T1-weighted conventional spin-echo sequences. Dubin MD, Teresi LM, Bradley WG, Jordan JE, Pema PJ, Goergen SK, Tam JK. AJR Am J Roentgenol; 1995 May; 164(5):1213-21. PubMed ID: 7717234 [Abstract] [Full Text] [Related]
10. Contrast-enhanced 3-dimensional SPACE versus MP-RAGE for the detection of brain metastases: considerations with a 32-channel head coil. Reichert M, Morelli JN, Runge VM, Tao A, von Ritschl R, von Ritschl A, Padua A, Dix JE, Marra MJ, Schoenberg SO, Attenberger UI. Invest Radiol; 2013 Jan; 48(1):55-60. PubMed ID: 23192164 [Abstract] [Full Text] [Related]
11. Prostate cancer: Comparison of 3D T2-weighted with conventional 2D T2-weighted imaging for image quality and tumor detection. Rosenkrantz AB, Neil J, Kong X, Melamed J, Babb JS, Taneja SS, Taouli B. AJR Am J Roentgenol; 2010 Feb; 194(2):446-52. PubMed ID: 20093608 [Abstract] [Full Text] [Related]
12. Preoperative 3T MR imaging of rectal cancer: local staging accuracy using a two-dimensional and three-dimensional T2-weighted turbo spin echo sequence. Fütterer JJ, Yakar D, Strijk SP, Barentsz JO. Eur J Radiol; 2008 Jan; 65(1):66-71. PubMed ID: 18164156 [Abstract] [Full Text] [Related]
13. [The staging of bladder tumors in MRT: the value of the intravesical application of an iron oxide-containing contrast medium in combination with high-resolution T2-weighted imaging]. Beyersdorff D, Taupitz M, Giessing M, Türk I, Schnorr D, Loening S, Hamm B. Rofo; 2000 Jun; 172(6):504-8. PubMed ID: 10916545 [Abstract] [Full Text] [Related]
14. Characterization of carotid atherosclerosis with black-blood carotid plaque imaging using variable flip-angle 3D turbo spin-echo: comparison with 2D turbo spin-echo sequences. Takano K, Yamashita S, Takemoto K, Inoue T, Sakata N, Kuwabara Y, Yoshimitsu K. Eur J Radiol; 2012 Mar; 81(3):e304-9. PubMed ID: 22115798 [Abstract] [Full Text] [Related]
15. [Preoperative staging of bladder carcinomas with Gd-DTPA-supported dynamic magnetic resonance tomography. Comparison with plain and Gd-DTPA-supported spin-echo sequences]. Venz S, Hosten N, Ilg J, Mäurer J, Podrabsky P, Fedel M, Ebert T, Nagel R. Rofo; 1996 Mar; 164(3):218-25. PubMed ID: 8672777 [Abstract] [Full Text] [Related]
16. Dynamic gadolinium-enhanced magnetic resonance imaging in staging of superficial bladder cancer. Scattoni V, Da Pozzo LF, Colombo R, Nava L, Rigatti P, De Cobelli F, Vanzulli A, Del Maschio A. J Urol; 1996 May; 155(5):1594-9. PubMed ID: 8627831 [Abstract] [Full Text] [Related]
17. Preoperative staging of cervical carcinoma: phased array coil fast spin-echo versus body coil spin-echo T2-weighted MR imaging. Yu KK, Hricak H, Subak LL, Zaloudek CJ, Powell CB. AJR Am J Roentgenol; 1998 Sep; 171(3):707-11. PubMed ID: 9725301 [Abstract] [Full Text] [Related]
18. MP RAGE: a three-dimensional, T1-weighted, gradient-echo sequence--initial experience in the brain. Brant-Zawadzki M, Gillan GD, Nitz WR. Radiology; 1992 Mar; 182(3):769-75. PubMed ID: 1535892 [Abstract] [Full Text] [Related]
19. MR imaging of the brain: comparison of gradient-echo and spin-echo pulse sequences. Pui MH, Fok EC. AJR Am J Roentgenol; 1995 Oct; 165(4):959-62. PubMed ID: 7677001 [Abstract] [Full Text] [Related]
20. Squamous cell carcinoma of the oral cavity: MR findings and value of T1-versus T2-weighted fast spin-echo images. Yasumoto M, Shibuya H, Takeda M, Korenaga T. AJR Am J Roentgenol; 1995 Apr; 164(4):981-7. PubMed ID: 7726062 [Abstract] [Full Text] [Related] Page: [Next] [New Search]