These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
109 related items for PubMed ID: 8116415
21. Mechanisms of failure of modular prostheses. Collier JP, Mayor MB, Jensen RE, Surprenant VA, Surprenant HP, McNamar JL, Belec L. Clin Orthop Relat Res; 1992 Dec; (285):129-39. PubMed ID: 1446428 [Abstract] [Full Text] [Related]
22. Osteointegration of bone graft in porous-coated total hip arthroplasty. Clarke HJ, Jinnah RH, Lennox D. Clin Orthop Relat Res; 1990 Sep; (258):160-7. PubMed ID: 2394044 [Abstract] [Full Text] [Related]
23. [The Balgrist acetabulum with uncemented endoprosthesis of dysplastic coxarthrosis and other acetabulum defects]. Hauser R. Z Orthop Ihre Grenzgeb; 1991 Sep; 129(2):183-7. PubMed ID: 1829301 [Abstract] [Full Text] [Related]
24. The porous-coated anatomic total hip prosthesis: failure of the metal-backed acetabular component. Astion DJ, Saluan P, Stulberg BN, Rimnac CM, Li S. J Bone Joint Surg Am; 1996 May; 78(5):755-66. PubMed ID: 8642033 [Abstract] [Full Text] [Related]
25. Pelvic lysis and polyethylene wear at 5-8 years in an uncemented total hip. Barrack RL, Folgueras A, Munn B, Tvetden D, Sharkey P. Clin Orthop Relat Res; 1997 Feb; (335):211-7. PubMed ID: 9020220 [Abstract] [Full Text] [Related]
26. Osteolysis around uncemented acetabular components of cobalt-chrome surface replacement hip arthroplasty. Buechel FF, Drucker D, Jasty M, Jiranek W, Harris WH. Clin Orthop Relat Res; 1994 Jan; (298):202-11. PubMed ID: 8118977 [Abstract] [Full Text] [Related]
27. [5 years' experiences with the Gersthof polyethylene peg-anchored acetabulum]. Knahr K, Böhler M, Frank P, Plenk H, Salzer M. Z Orthop Ihre Grenzgeb; 1987 Jan; 125(4):375-81. PubMed ID: 3673191 [Abstract] [Full Text] [Related]
28. Total hip acetabular cup flange design and its effect on cement fixation. Oh I, Sander TW, Treharne RW. Clin Orthop Relat Res; 1985 May; (195):304-9. PubMed ID: 3978965 [Abstract] [Full Text] [Related]
30. Separation of the polyethylene liner from acetabular cup metal backing. A report of three cases. Ries MD, Collis DK, Lynch F. Clin Orthop Relat Res; 1992 Sep; (282):164-9. PubMed ID: 1516308 [Abstract] [Full Text] [Related]
31. Complications of femoral and acetabular modularity. Salvati EA, Lieberman JR, Huk OL, Evans BG. Clin Orthop Relat Res; 1995 Oct; (319):85-93. PubMed ID: 7554653 [Abstract] [Full Text] [Related]
32. Tissue growth into porous-coated acetabular components in 42 patients. Effects of adjunct fixation. Cook SD, Thomas KA, Barrack RL, Whitecloud TS. Clin Orthop Relat Res; 1992 Oct; (283):163-70. PubMed ID: 1395241 [Abstract] [Full Text] [Related]
33. Considerations on seven cases of breakage of the polyethylene acetabular cup. Federici A, Sanguineti F, Santolini F, Gatto P. Chir Organi Mov; 1993 Oct; 78(3):155-60. PubMed ID: 8243134 [Abstract] [Full Text] [Related]
34. Uncemented total hip arthroplasty with superior acetabular deficiency. Femoral head autograft technique and early clinical results. Barrack RL, Newland CC. J Arthroplasty; 1990 Jun; 5(2):159-67. PubMed ID: 2358815 [Abstract] [Full Text] [Related]
39. [Roentgen criteria and radiologic results of the Hofer-Imhof (H-I) threaded acetabulum cup in first time implantation]. Effenberger H, Weber M, Dorn U, Hofer H. Z Orthop Ihre Grenzgeb; 1997 Sep; 135(5):434-43. PubMed ID: 9446437 [Abstract] [Full Text] [Related]
40. Contact finite element stress analysis of porous ingrowth acetabular cup implantation, ingrowth, and loosening. Rapperport DJ, Carter DR, Schurman DJ. J Orthop Res; 1987 Sep; 5(4):548-61. PubMed ID: 3681529 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]