These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
164 related items for PubMed ID: 8353961
1. Evaluation of evacuated blood-collection tubes: effects of three types of polymeric separators on therapeutic drug-monitoring specimens. Landt M, Smith CH, Hortin GL. Clin Chem; 1993 Aug; 39(8):1712-7. PubMed ID: 8353961 [Abstract] [Full Text] [Related]
2. Evaluation of serum and rapid serum separator collection tubes for therapeutic drug assays. Garza KY, Carter J, Mercer A, Jarrar P, Martin J, Daughtry S, Mahomes A, Knezevic CE. Clin Biochem; 2023 May; 115():81-85. PubMed ID: 36027943 [Abstract] [Full Text] [Related]
3. Absorption of therapeutic drugs by barrier gels in serum separator blood collection tubes. Volume- and time-dependent reduction in total and free drug concentrations. Dasgupta A, Dean R, Saldana S, Kinnaman G, McLawhon RW. Am J Clin Pathol; 1994 Apr; 101(4):456-61. PubMed ID: 8160636 [Abstract] [Full Text] [Related]
4. Stability of therapeutic drug measurement in specimens collected in VACUTAINER plastic blood-collection tubes. Dasgupta A, Blackwell W, Bard D. Ther Drug Monit; 1996 Jun; 18(3):306-9. PubMed ID: 8738774 [Abstract] [Full Text] [Related]
5. Stability of drug concentrations in plasma stored in serum separator blood collection tubes. Bailey DN, Coffee JJ, Briggs JR. Ther Drug Monit; 1988 Jun; 10(3):352-4. PubMed ID: 3176115 [Abstract] [Full Text] [Related]
6. Evaluation of BD Barricor™ and PST™ blood collection tubes compared to serum for testing 11 therapeutic drugs on a Roche Cobas® 8000 platform. Jordan A, Sherazi A, Stevens A, Quondam Franks C, Sturgeon K, Northrup V, Shea JL. Clin Biochem; 2022 Feb; 100():60-66. PubMed ID: 34788637 [Abstract] [Full Text] [Related]
7. Assessment of the Corvac blood collection tube for drug specimen processing. Devine JE. Ther Drug Monit; 1986 Feb; 8(2):241-3. PubMed ID: 3726942 [Abstract] [Full Text] [Related]
8. Monoject Samplette capillary blood container with serum separator evaluated for collection of specimens for therapeutic drug assays and common clinical-chemical tests. Landt M, Norling LL, Steelman M, Smith CH. Clin Chem; 1986 Mar; 32(3):523-6. PubMed ID: 3948399 [Abstract] [Full Text] [Related]
9. Time-dependent absorption of therapeutic drugs by the gel of the Greiner Vacuette blood collection tube. Dasgupta A, Yared MA, Wells A. Ther Drug Monit; 2000 Aug; 22(4):427-31. PubMed ID: 10942183 [Abstract] [Full Text] [Related]
10. A new plastic evacuated tube with plasma separator. Landt M, Wilhite TR, Smith CH. J Clin Lab Anal; 1995 Aug; 9(2):101-6. PubMed ID: 7714661 [Abstract] [Full Text] [Related]
11. Clinical evaluation of the Abbott TDx fluorescence polarization immunoassay analyzer. Oeltgen PR, Shank WA, Blouin RA, Clark T. Ther Drug Monit; 1984 Aug; 6(3):360-7. PubMed ID: 6390799 [Abstract] [Full Text] [Related]
12. Stability of therapeutic drugs in serum collected in vacutainer serum separator tubes containing a new gel (SST II). Bush V, Blennerhasset J, Wells A, Dasgupta A. Ther Drug Monit; 2001 Jun; 23(3):259-62. PubMed ID: 11360035 [Abstract] [Full Text] [Related]
13. Effect of use of gel-barrier sampling tubes on determination of some antiepileptic drugs in serum. Bergqvist Y, Eckerbom S, Funding L. Clin Chem; 1984 Mar; 30(3):465-6. PubMed ID: 6697500 [Abstract] [Full Text] [Related]
14. [Determination and stability of 4 therapeutic drugs collected into evacuated tubes with serum gel separator]. Vigier JP, Guerber F, Pinel N. Ann Biol Clin (Paris); 2000 Mar; 58(6):738-9. PubMed ID: 11098172 [No Abstract] [Full Text] [Related]
15. Effect of serum separator tubes on free and total phenytoin and carbamazepine serum concentrations. Mauro LS, Mauro VF. Ther Drug Monit; 1991 May; 13(3):240-3. PubMed ID: 1926278 [Abstract] [Full Text] [Related]
16. Do evacuated blood collection tubes interfere with therapeutic drug monitoring? Janknegt R, Lohman JJ, Hooymans PM, Merkus FW. Pharm Weekbl Sci; 1983 Dec 16; 5(6):287-90. PubMed ID: 6664820 [Abstract] [Full Text] [Related]
17. A Multicenter Evaluation of a Nongel Mechanical Separator Plasma Blood Collection Tube for Testing of Selected Therapeutic Drugs. Morosyuk S, Berube J, Christenson R, Wu AHB, Uettwiller-Geiger D, Palicka V, Prusa R, Zima T, Shaw K, Plokhoy E, Ahuja AJ, Stankovic AK. J Appl Lab Med; 2020 Jul 01; 5(4):671-685. PubMed ID: 32603441 [Abstract] [Full Text] [Related]
18. Suitability of collection tubes with separator gels for therapeutic drug monitoring. Koch TR, Platoff G. Ther Drug Monit; 1990 May 01; 12(3):277-80. PubMed ID: 2349612 [Abstract] [Full Text] [Related]
19. Stability of digoxin and digitoxin in specimens collected in blood collection tubes containing serum separator gels. Datta P. Clin Biochem; 1998 Jun 01; 31(4):273-5. PubMed ID: 9646952 [No Abstract] [Full Text] [Related]
20. Evaluation of three different specimen types (serum, plasma lithium heparin and serum gel separator) for analysis of certain analytes: clinical significance of differences in results and efficiency in use. O'Keane MP, Cunningham SK. Clin Chem Lab Med; 2006 Jun 01; 44(5):662-8. PubMed ID: 16681442 [Abstract] [Full Text] [Related] Page: [Next] [New Search]