These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
905 related items for PubMed ID: 8436759
1. Measurements of cardiac output by impedance cardiography in pacemaker patients at rest: effects of various atrioventricular delays. Ovsyshcher I, Zimlichman R, Katz A, Bondy C, Furman S. J Am Coll Cardiol; 1993 Mar 01; 21(3):761-7. PubMed ID: 8436759 [Abstract] [Full Text] [Related]
2. Importance of heart rate response during exercise in patients using atrioventricular synchronous and ventricular pacemakers. McMeekin JD, Lautner D, Hanson S, Gulamhusein SS. Pacing Clin Electrophysiol; 1990 Jan 01; 13(1):59-68. PubMed ID: 1689036 [Abstract] [Full Text] [Related]
4. [The effect of changes in stroke volume on QT dispersion during long-term DDD and VVI pacing]. Lelakowski J, Majewski J, Bednarek J, Szczepkowski J, Machejek J. Przegl Lek; 2001 Jan 01; 58(3):111-6. PubMed ID: 11475854 [Abstract] [Full Text] [Related]
5. Superior cardiac hemodynamics of atrioventricular synchrony over rate responsive pacing at submaximal exercise: observations in activity sensing DDDR pacemakers. Lau CP, Wong CK, Leung WH, Liu WX. Pacing Clin Electrophysiol; 1990 Dec 01; 13(12 Pt 2):1832-7. PubMed ID: 1704550 [Abstract] [Full Text] [Related]
6. Lack of influence of atrioventricular delay on stroke volume at rest in patients with complete atrioventricular block and dual chamber pacing. Occhetta E, Piccinino C, Francalacci G, Magnani A, Bolognese L, Devecchi P, Rognoni G, Rossi P. Pacing Clin Electrophysiol; 1990 Jul 01; 13(7):916-26. PubMed ID: 1695749 [Abstract] [Full Text] [Related]
8. Clinical and hemodynamic comparison of VVI versus DDD pacing in patients with DDD pacemakers. Rediker DE, Eagle KA, Homma S, Gillam LD, Harthorne JW. Am J Cardiol; 1988 Feb 01; 61(4):323-9. PubMed ID: 3341209 [Abstract] [Full Text] [Related]
11. Higher sympathetic nerve activity during ventricular (VVI) than during dual-chamber (DDD) pacing. Taylor JA, Morillo CA, Eckberg DL, Ellenbogen KA. J Am Coll Cardiol; 1996 Dec 01; 28(7):1753-8. PubMed ID: 8962562 [Abstract] [Full Text] [Related]
12. Beat-to-beat variability in stroke volume during VVI pacing as predictor of hemodynamic benefit from DDD pacing. Dritsas A, Joshi J, Webb SC, Athanassopoulos G, Oakley CM, Nihoyannopoulos P. Pacing Clin Electrophysiol; 1993 Aug 01; 16(8):1713-8. PubMed ID: 7690940 [Abstract] [Full Text] [Related]
14. A randomized study on the effects of pacemaker programming to a lower output on projected pulse generator longevity. Schuchert A, Meinertz T, Low Output Programming (LOP) Investigators. Pacing Clin Electrophysiol; 2001 Aug 01; 24(8 Pt 1):1234-9. PubMed ID: 11523609 [Abstract] [Full Text] [Related]
15. Assessment of the optimal atrio-ventricular delay in DDD paced patients by impedance plethysmography. Eugene M, Lascault G, Frank R, Fontaine G, Grosgogeat Y, Teillac A. Eur Heart J; 1989 Mar 01; 10(3):250-5. PubMed ID: 2707272 [Abstract] [Full Text] [Related]
16. Hemodynamic importance of preserving the normal sequence of ventricular activation in permanent cardiac pacing. Leclercq C, Gras D, Le Helloco A, Nicol L, Mabo P, Daubert C. Am Heart J; 1995 Jun 01; 129(6):1133-41. PubMed ID: 7754944 [Abstract] [Full Text] [Related]
17. Dual chamber cardiac pacing in children: Single chamber pacing dual chamber sensing cardiac pacemaker or dual chamber pacing and sensing cardiac pacemaker? Bostan OM, Celiker A, Karagöz T, Ozer S, Ozme S. Pediatr Int; 2002 Dec 01; 44(6):635-40. PubMed ID: 12421261 [Abstract] [Full Text] [Related]
18. Evaluation of the early hemodynamic changes in carotid arteries during ventricular and dual chamber pacing. Soylu M, Ozdemir O, Geyik B, Ozbakir C, Demir AD, Duru E, Ozbal S, Hekimoglu B, Ozer T, Arda K. Pacing Clin Electrophysiol; 2004 Nov 01; 27(11):1540-4. PubMed ID: 15546310 [Abstract] [Full Text] [Related]