These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
127 related items for PubMed ID: 8537025
1. Self-assessment of angles of strabismus with photographic Purkinje I and IV reflection pattern evaluation. Effert R, Barry JC, Colberg R, Kaupp A, Scherer G. Graefes Arch Clin Exp Ophthalmol; 1995 Aug; 233(8):494-506. PubMed ID: 8537025 [Abstract] [Full Text] [Related]
2. [Detection and diagnosis of small ocular misalignment with the Purkinje reflex pattern method]. Barry JC, Effert R, Hoffmann N. Klin Monbl Augenheilkd; 1996 Mar; 208(3):167-80. PubMed ID: 8699775 [Abstract] [Full Text] [Related]
3. Measurement of ocular alignment with photographic Purkinje I and IV reflection pattern evaluation. Barry JC, Effert R, Kaupp A, Burhoff A. Invest Ophthalmol Vis Sci; 1994 Dec; 35(13):4219-35. PubMed ID: 8002242 [Abstract] [Full Text] [Related]
4. [Computer-assisted measurement of ocular misalignment in infants and young children using the digital Purkinje reflection pattern procedure]. Barry JC, Effert R, Kaupp A, Kleine M, Reim M. Ophthalmologe; 1994 Feb; 91(1):51-61. PubMed ID: 8173252 [Abstract] [Full Text] [Related]
5. Computational principles in Purkinje I and IV reflection pattern evaluation for the assessment of ocular alignment. Barry JC, Effert R, Reim M, Meyer-Ebrecht D. Invest Ophthalmol Vis Sci; 1994 Dec; 35(13):4205-18. PubMed ID: 8002241 [Abstract] [Full Text] [Related]
6. Objective measurement of small angles of strabismus in infants and children with photographic reflection pattern evaluation. Barry JC, Effert R, Kaupp A. Ophthalmology; 1992 Mar; 99(3):320-8. PubMed ID: 1565443 [Abstract] [Full Text] [Related]
7. [A new photographic method for measuring squint angles in infants and small children]. Effert R, Barry JC, Dahm M, Kaupp A. Klin Monbl Augenheilkd; 1991 Apr; 198(4):284-9. PubMed ID: 1861407 [Abstract] [Full Text] [Related]
8. Vertical location of the corneal light reflex in strabismus photography. Hunter DG, Guyton DL. Arch Ophthalmol; 1998 Jun; 116(6):767-71. PubMed ID: 9639445 [Abstract] [Full Text] [Related]
9. Rate of Strabismus Detection on Digital Photographs Increases by Using Off-center Near Target. Maor R, Holland J, Tailor V, Banteka M, Khandelwal P, Glaze S, Barnard S, Yashiv Y, Dahlmann-Noor AH. J Pediatr Ophthalmol Strabismus; 2017 Mar 01; 54(2):90-96. PubMed ID: 28092398 [Abstract] [Full Text] [Related]
10. To compare horizontal strabismus deviation as assessed from photographs with that in the strabismus clinic using the prism bar. Bose A, Amitava AK, Gupta Y, Sharma N, Raza SA, Masood A, Singh R, Meena G. Indian J Ophthalmol; 2024 Aug 01; 72(8):1199-1203. PubMed ID: 39078965 [Abstract] [Full Text] [Related]
11. Evaluation of a Hirschberg Test-Based Application for Measuring Ocular Alignment and Detecting Strabismus. Garcia SSS, Santiago APD, Directo PMC. Curr Eye Res; 2021 Nov 01; 46(11):1768-1776. PubMed ID: 33856941 [Abstract] [Full Text] [Related]
12. Variability of Ocular Deviation in Strabismus. Economides JR, Adams DL, Horton JC. JAMA Ophthalmol; 2016 Jan 01; 134(1):63-9. PubMed ID: 26562632 [Abstract] [Full Text] [Related]
13. [Systemic bias in the photographic assessment of the first purkinje image]. Becker R, Gräf M. Klin Monbl Augenheilkd; 2006 Apr 01; 223(4):294-6. PubMed ID: 16639666 [Abstract] [Full Text] [Related]
17. Accurate gaze direction measurements with free head movement for strabismus angle estimation. Bakker NM, Lenseigne BA, Schutte S, Geukers EB, Jonker PP, van der Helm FC, Simonsz HJ. IEEE Trans Biomed Eng; 2013 Nov 01; 60(11):3028-35. PubMed ID: 23399951 [Abstract] [Full Text] [Related]
18. Quantitative measurement of horizontal strabismus with digital photography. Dericioğlu V, Çerman E. J AAPOS; 2019 Feb 01; 23(1):18.e1-18.e6. PubMed ID: 30682411 [Abstract] [Full Text] [Related]
19. A simple method for screening of children with strabismus, anisometropia or ametropia by simultaneous photography of the corneal and the fundus reflexes. Kaakinen K. Acta Ophthalmol (Copenh); 1979 Apr 01; 57(2):161-71. PubMed ID: 452880 [Abstract] [Full Text] [Related]
20. Eye position changes induced by neck muscle vibration in strabismic subjects. Han Y, Lennerstrand G. Graefes Arch Clin Exp Ophthalmol; 1999 Jan 01; 237(1):21-8. PubMed ID: 9951637 [Abstract] [Full Text] [Related] Page: [Next] [New Search]