These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


160 related items for PubMed ID: 8549196

  • 21. False aneurysm of the pulmonary artery induced by a Swan-Ganz catheter: clinical presentation and radiologic management.
    Ferretti GR, Thony F, Link KM, Durand M, Wollschläger K, Blin D, Coulomb M.
    AJR Am J Roentgenol; 1996 Oct; 167(4):941-5. PubMed ID: 8819388
    [Abstract] [Full Text] [Related]

  • 22. Pulmonary artery pseudoaneurysm secondary to Swan-Ganz catheterization--a case report.
    Pezzulli F, Goldberg N, Posner D.
    Australas Radiol; 1992 Feb; 36(1):59-61. PubMed ID: 1632750
    [No Abstract] [Full Text] [Related]

  • 23. Swan-Ganz-induced pulmonary artery rupture: management with stent graft implantation.
    Zuffi A, Biondi-Zoccai G, Colombo F.
    Catheter Cardiovasc Interv; 2010 Oct 01; 76(4):578-81. PubMed ID: 20506369
    [Abstract] [Full Text] [Related]

  • 24. Successfully treated pulmonary artery rupture complicated by aneurysm formation.
    Roberts LC, Ramsay MA, Alivizatos PA, Walling PT, Lee SP.
    J Cardiothorac Vasc Anesth; 1992 Feb 01; 6(1):70-2. PubMed ID: 1543859
    [No Abstract] [Full Text] [Related]

  • 25. It was a nice sunny day: it was just a right heart catheterization.
    Butman SM.
    Catheter Cardiovasc Interv; 2010 Oct 01; 76(4):582-3. PubMed ID: 20882663
    [No Abstract] [Full Text] [Related]

  • 26. Successful Management of a Patient With Pulmonary Artery Rupture in a Catheterization Suite.
    Addante RA, Chen J, Goswami S.
    J Cardiothorac Vasc Anesth; 2016 Dec 01; 30(6):1618-1620. PubMed ID: 27178098
    [No Abstract] [Full Text] [Related]

  • 27. [Massive endobronchial hemorrhage due to pulmonary artery rupture caused by a Swan-Ganz catheter].
    Santacana E, Litvan H, Aris A, Montiel J, Villar-Landeira JM.
    Rev Esp Anestesiol Reanim; 1993 Dec 01; 40(4):230-3. PubMed ID: 8372263
    [Abstract] [Full Text] [Related]

  • 28. Pulmonary artery rupture during Swan-Ganz catheterisation: a case report.
    Villaverde RV, Vanhaebost J, Grabherr S, Palmiere C.
    Leg Med (Tokyo); 2014 Mar 01; 16(2):76-80. PubMed ID: 24332120
    [Abstract] [Full Text] [Related]

  • 29.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 30.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 31. Pulmonary artery false aneurysms secondary to Swan-Ganz pulmonary artery catheters.
    Dieden JD, Friloux LA, Renner JW.
    AJR Am J Roentgenol; 1987 Nov 01; 149(5):901-6. PubMed ID: 3499793
    [Abstract] [Full Text] [Related]

  • 32.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 33. Avoiding pulmonary artery rupture.
    Wajon P.
    Anaesth Intensive Care; 1997 Oct 01; 25(5):578-9. PubMed ID: 9352774
    [No Abstract] [Full Text] [Related]

  • 34.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 35.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 36. Managing pulmonary artery catheter-induced pulmonary hemorrhage by bronchial occlusion.
    Schramm R, Abugameh A, Tscholl D, Schäfers HJ.
    Ann Thorac Surg; 2009 Jul 01; 88(1):284-7. PubMed ID: 19559249
    [Abstract] [Full Text] [Related]

  • 37. [Massive hemoptysis as an unusual complication of right heart catheterization. Temporary hemostasis with a Berman diagnostic catheter].
    Gallardo A, Jiménez-Mazuecos J, Gutiérrez A, Melehi D.
    Rev Esp Cardiol; 2008 Jan 01; 61(1):99-101. PubMed ID: 18221704
    [No Abstract] [Full Text] [Related]

  • 38.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 39.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 40.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]