These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
840 related items for PubMed ID: 8572119
1. Cochlear pathology following reimplantation of a multichannel scala tympani electrode array in the macaque. Shepherd RK, Clark GM, Xu SA, Pyman BC. Am J Otol; 1995 Mar; 16(2):186-99. PubMed ID: 8572119 [Abstract] [Full Text] [Related]
2. [Evaluation of the insertion-trauma of the Nucleus Contour Advance electrode-array in a human temporal bone model]. Klenzner T, Richter B, Nagursky H, Schipper J, Laszig R, Aschendorff A. Laryngorhinootologie; 2004 Dec; 83(12):840-4. PubMed ID: 15611904 [Abstract] [Full Text] [Related]
3. The internal dimensions of the cochlear scalae with special reference to cochlear electrode insertion trauma. Biedron S, Prescher A, Ilgner J, Westhofen M. Otol Neurotol; 2010 Jul; 31(5):731-7. PubMed ID: 20142798 [Abstract] [Full Text] [Related]
5. [Cochlear pathology following chronic electrical stimulation in cats]. Ni DF. Zhonghua Er Bi Yan Hou Ke Za Zhi; 1993 Jul; 28(1):11-3, 58. PubMed ID: 8352990 [Abstract] [Full Text] [Related]
6. Combining perimodiolar electrode placement and atraumatic insertion properties in cochlear implantation -- fact or fantasy? Adunka OF, Pillsbury HC, Kiefer J. Acta Otolaryngol; 2006 May; 126(5):475-82. PubMed ID: 16698696 [Abstract] [Full Text] [Related]
7. Chronic electrical stimulation of the auditory nerve at high stimulus rates: a physiological and histopathological study. Xu J, Shepherd RK, Millard RE, Clark GM. Hear Res; 1997 Mar; 105(1-2):1-29. PubMed ID: 9083801 [Abstract] [Full Text] [Related]
12. Comparison of round window and cochleostomy approaches with a prototype hearing preservation electrode. Briggs RJ, Tykocinski M, Xu J, Risi F, Svehla M, Cowan R, Stover T, Erfurt P, Lenarz T. Audiol Neurootol; 2006 Mar; 11 Suppl 1():42-8. PubMed ID: 17063010 [Abstract] [Full Text] [Related]
13. [Evaluation of an electrode design for the combined electric-acoustic stimulation]. Adunka O, Kiefer J, Unkelbach MH, Radeloff A, Lehnert T, Gstöttner W. Laryngorhinootologie; 2004 Oct; 83(10):653-8. PubMed ID: 15476137 [Abstract] [Full Text] [Related]
14. Development and evaluation of an improved cochlear implant electrode design for electric acoustic stimulation. Adunka O, Kiefer J, Unkelbach MH, Lehnert T, Gstoettner W. Laryngoscope; 2004 Jul; 114(7):1237-41. PubMed ID: 15235353 [Abstract] [Full Text] [Related]
15. Electrical impedance measurements of cochlear structures using the four-electrode reflection-coefficient technique. Kumar G, Chokshi M, Richter CP. Hear Res; 2010 Jan; 259(1-2):86-94. PubMed ID: 19857561 [Abstract] [Full Text] [Related]