These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
330 related items for PubMed ID: 8596819
1. Examination of a resin-modified glass-ionomer material as a pit and fissure sealant. Johnson LM, Duke ES, Camm J, Hermesch CB, Buikema DJ. Quintessence Int; 1995 Dec; 26(12):879-83. PubMed ID: 8596819 [Abstract] [Full Text] [Related]
2. In vitro evaluation of sealing pits and fissures with newer glass-ionomer cements developed for the ART technique. Smales RJ, Gao W, Ho FT. J Clin Pediatr Dent; 1997 Dec; 21(4):321-3. PubMed ID: 9484119 [Abstract] [Full Text] [Related]
3. The effect of a sealant on the microleakage of composite resin restorations: an in vivo study. Akyüz S, Menteş A, Oktay C. J Marmara Univ Dent Fac; 1992 Sep; 1(3):211-4. PubMed ID: 1308779 [Abstract] [Full Text] [Related]
4. Comparison between two glass-ionomer sealants placed using finger pressure (ART approach) and a ball burnisher. Beiruti N, Frencken JE, Mulder J. Am J Dent; 2006 Jun; 19(3):159-62. PubMed ID: 16838480 [Abstract] [Full Text] [Related]
5. Marginal leakage of two newer glass-ionomer-based sealant materials assessed using micro-CT. Chen X, Cuijpers V, Fan M, Frencken JE. J Dent; 2010 Sep; 38(9):731-5. PubMed ID: 20580767 [Abstract] [Full Text] [Related]
6. Handling and clinical performance of a glass ionomer sealant. Smales RJ, Lee YK, Lo FW, Tse CC, Chung MS. Am J Dent; 1996 Oct; 9(5):203-5. PubMed ID: 9545905 [Abstract] [Full Text] [Related]
7. Microleakage evaluation of pit and fissure sealants done with different procedures, materials, and laser after invasive technique. do Rego MA, de Araujo MA. J Clin Pediatr Dent; 1999 Oct; 24(1):63-8. PubMed ID: 10709546 [Abstract] [Full Text] [Related]
8. Microtensile bond strength to ground enamel by glass-ionomers, resin-modified glass-ionomers, and resin composites used as pit and fissure sealants. Papacchini F, Goracci C, Sadek FT, Monticelli F, Garcia-Godoy F, Ferrari M. J Dent; 2005 Jul; 33(6):459-67. PubMed ID: 15935265 [Abstract] [Full Text] [Related]
9. Caries-preventive effect of sealants produced with altered glass-ionomer materials, after 2 years. Chen X, Du MQ, Fan MW, Mulder J, Huysmans MC, Frencken JE. Dent Mater; 2012 May; 28(5):554-60. PubMed ID: 22300651 [Abstract] [Full Text] [Related]
10. Penetration of a light-cured glass ionomer and a resin sealant into occlusal fissures and etched enamel. Percinoto C, Cunha RF, Delbem AC, Aragones A. Am J Dent; 1995 Feb; 8(1):20-2. PubMed ID: 7546467 [Abstract] [Full Text] [Related]
11. Comparative evaluation of the marginal sealing ability of Fuji VII and Concise as pit and fissure sealants. Ganesh M, Shobha T. J Contemp Dent Pract; 2007 May 01; 8(4):10-8. PubMed ID: 17486182 [Abstract] [Full Text] [Related]
12. Short-term retention of glass-ionomer fissure sealants. Torppa-Saarinen E, Seppä L. Proc Finn Dent Soc; 1990 May 01; 86(2):83-8. PubMed ID: 2287613 [Abstract] [Full Text] [Related]
13. Effect of thermocycling on the microleakage of conventional and resin-modified glass ionomers. Doerr CL, Hilton TJ, Hermesch CB. Am J Dent; 1996 Feb 01; 9(1):19-21. PubMed ID: 9002809 [Abstract] [Full Text] [Related]
14. Enhanced retention of glass-ionomer sealant by enamel etching: a microleakage and scanning electron microscopic study. Birkenfeld LH, Schulman A. Quintessence Int; 1999 Oct 01; 30(10):712-8. PubMed ID: 10765856 [Abstract] [Full Text] [Related]
15. Penetration and microleakage of dental sealants in artificial fissures. Droz D, Schiele MJ, Panighi MM. J Dent Child (Chic); 2004 Oct 01; 71(1):41-4. PubMed ID: 15272655 [Abstract] [Full Text] [Related]
16. Moisture susceptibility of resin-modified glass-ionomer materials. Cho E, Kopel H, White SN. Quintessence Int; 1995 May 01; 26(5):351-8. PubMed ID: 7568759 [Abstract] [Full Text] [Related]
17. Effect of tooth preparation on sealant success--an in vitro study. Subramaniam P, Babu KL, Naveen HK. J Clin Pediatr Dent; 2009 May 01; 33(4):325-31. PubMed ID: 19725240 [Abstract] [Full Text] [Related]
18. A three-year follow-up of glass ionomer cement and resin fissure sealants. Karlzén-Reuterving G, van Dijken JW. ASDC J Dent Child; 1995 May 01; 62(2):108-10. PubMed ID: 7608367 [Abstract] [Full Text] [Related]
19. Microleakage of two fluoride-releasing sealants when applied following saliva contamination. Rirattanapong P, Vongsavan K, Surarit R. Southeast Asian J Trop Med Public Health; 2013 Sep 01; 44(5):931-4. PubMed ID: 24437329 [Abstract] [Full Text] [Related]
20. Microleakage at sealant/enamel interface of primary teeth: effect of Er:YAG laser ablation of pits and fissures. Borsatto MC, Corona SA, Ramos RP, Liporaci JL, Pécora JD, Palma-Dibb RG. J Dent Child (Chic); 2004 Sep 01; 71(2):143-7. PubMed ID: 15587098 [Abstract] [Full Text] [Related] Page: [Next] [New Search]