These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
116 related items for PubMed ID: 8655386
1. Collimator (head) scatter at extended distances in linear accelerator-generated photon beams. Khan FM, Gibbons JP, Roback DM. Int J Radiat Oncol Biol Phys; 1996 Jun 01; 35(3):605-8. PubMed ID: 8655386 [Abstract] [Full Text] [Related]
2. Part I: Out-of-field dose mapping for 6X and 6X-flattening-filter-free beams on the TrueBeam for extended distances. Wijesooriya K. Med Phys; 2019 Feb 01; 46(2):868-876. PubMed ID: 30589941 [Abstract] [Full Text] [Related]
3. Head-scatter factors and effective x-ray source positions in a 25-MV linear accelerator. Tatcher M, Bjärngard B. Med Phys; 1992 Feb 01; 19(3):685-6. PubMed ID: 1508107 [Abstract] [Full Text] [Related]
4. Flattening-filter-based empirical methods to parametrize the head scatter factor. Lam KL, Muthuswamy MS, Ten Haken RK. Med Phys; 1996 Mar 01; 23(3):343-52. PubMed ID: 8815376 [Abstract] [Full Text] [Related]
5. A generalized solution for the calculation of in-air output factors in irregular fields. Kim S, Palta JR, Zhu TC. Med Phys; 1998 Sep 01; 25(9):1692-701. PubMed ID: 9775375 [Abstract] [Full Text] [Related]
6. An analytical formalism to calculate phantom scatter factors for flattening filter free (FFF) mode photon beams. Chung H, Prado KL, Yi BY. Phys Med Biol; 2014 Feb 21; 59(4):951-60. PubMed ID: 24503449 [Abstract] [Full Text] [Related]
7. Out-of-field photon dose following removal of the flattening filter from a medical accelerator. Kry SF, Vassiliev ON, Mohan R. Phys Med Biol; 2010 Apr 21; 55(8):2155-66. PubMed ID: 20305334 [Abstract] [Full Text] [Related]
8. Dosimetric properties of equivalent-quality flattening filter-free (FFF) and flattened photon beams of Versa HD linear accelerator. Meshram MN, Pramanik S, Ranjith CP, Gopal SK, Dobhal R. J Appl Clin Med Phys; 2016 May 08; 17(3):358-370. PubMed ID: 27167293 [Abstract] [Full Text] [Related]
9. The equivalent square concept for the head scatter factor based on scatter from flattening filter. Kim S, Palta JR, Zhu TC. Phys Med Biol; 1998 Jun 08; 43(6):1593-604. PubMed ID: 9651028 [Abstract] [Full Text] [Related]
10. Dosimetric properties of photon beams from a flattening filter free clinical accelerator. Vassiliev ON, Titt U, Pönisch F, Kry SF, Mohan R, Gillin MT. Phys Med Biol; 2006 Apr 07; 51(7):1907-17. PubMed ID: 16552113 [Abstract] [Full Text] [Related]
11. Collimator-related radiation dose for different cobalt machines and linear accelerators. van der Giessen PH. Int J Radiat Oncol Biol Phys; 1996 May 01; 35(2):399-405. PubMed ID: 8635949 [Abstract] [Full Text] [Related]
12. The fraction of photons undergoing head scatter in x-ray beams. Zhu TC, Bjärngard BE. Phys Med Biol; 1995 Jun 01; 40(6):1127-34. PubMed ID: 7659734 [Abstract] [Full Text] [Related]
13. Measurements of in-air output ratios for a linear accelerator with and without the flattening filter. Zhu XR, Kang Y, Gillin MT. Med Phys; 2006 Oct 01; 33(10):3723-33. PubMed ID: 17089838 [Abstract] [Full Text] [Related]
14. Monte Carlo study of photon fields from a flattening filter-free clinical accelerator. Vassiliev ON, Titt U, Kry SF, Pönisch F, Gillin MT, Mohan R. Med Phys; 2006 Apr 01; 33(4):820-7. PubMed ID: 16696457 [Abstract] [Full Text] [Related]
15. Flattening filter free beams in SBRT and IMRT: dosimetric assessment of peripheral doses. Kragl G, Baier F, Lutz S, Albrich D, Dalaryd M, Kroupa B, Wiezorek T, Knöös T, Georg D. Z Med Phys; 2011 May 01; 21(2):91-101. PubMed ID: 20888199 [Abstract] [Full Text] [Related]
16. Blocked field effects on collimator scatter factors. Higgins PD, Mihailidis DN, Khan FM, Lee EJ, Ahuja AS. Phys Med Biol; 1997 Dec 01; 42(12):2435-47. PubMed ID: 9434299 [Abstract] [Full Text] [Related]
17. Modeling the output ratio in air for megavoltage photon beams. Zhu TC, Bjärngard BE, Xiao Y, Yang CJ. Med Phys; 2001 Jun 01; 28(6):925-37. PubMed ID: 11439489 [Abstract] [Full Text] [Related]
18. Flattening filter free in intensity-modulated radiotherapy (IMRT) - Theoretical modeling with delivery efficiency analysis. Ma C, Chen M, Long T, Parsons D, Gu X, Jiang S, Hou Q, Lu W. Med Phys; 2019 Jan 01; 46(1):34-44. PubMed ID: 30371944 [Abstract] [Full Text] [Related]