These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
150 related items for PubMed ID: 8662105
21. [Use of a gamma probe for intraoperative localization of parathyroid adenomas with Tc-99m-tetrofosmin and Tc-99m-sestamibi]. Gallowitsch HJ, Fellinger J, Kresnik E, Mikosch P, Pipam W, Unterweger OF, Lind P. Acta Med Austriaca; 1997; 24(2):73-8. PubMed ID: 9273810 [Abstract] [Full Text] [Related]
24. Technetium-99m tetrofosmin parathyroid imaging in patients with primary hyperparathyroidism. Hiromatsu Y, Ishibashi M, Nishida H, Okuda S, Miyake I. Intern Med; 2000 Feb; 39(2):101-6. PubMed ID: 10732824 [Abstract] [Full Text] [Related]
25. Detection and localization of parathyroid adenomas in patients with hyperparathyroidism using a single radionuclide imaging procedure with technetium-99m-sestamibi (double-phase study). Taillefer R, Boucher Y, Potvin C, Lambert R. J Nucl Med; 1992 Oct; 33(10):1801-7. PubMed ID: 1328564 [Abstract] [Full Text] [Related]
26. Quantitative comparison of technetium-99m tetrofosmin and thallium-201 images of the thyroid and abnormal parathyroid glands. Giordano A, Marozzi P, Meduri G, Ficola U, Calcagni ML, Vaccaro A, Rubini G, Attard M, Li Puma M, Ricci R, Corsello S. Eur J Nucl Med; 1999 Aug; 26(8):907-11. PubMed ID: 10436206 [Abstract] [Full Text] [Related]
31. Technetium 99m-MIBI-SPECT: A highly sensitive diagnostic tool for localization of parathyroid adenomas. Moka D, Voth E, Dietlein M, Larena-Avellaneda A, Schicha H. Surgery; 2000 Jul; 128(1):29-35. PubMed ID: 10876182 [Abstract] [Full Text] [Related]
32. Parathyroid dual tracer subtraction scintigraphy: small regions method for quantitative assessment of parathyroid adenoma uptake. Koljević Marković A, Janković MM, Marković I, Pupić G, Džodić R, Delaloye AB. Ann Nucl Med; 2014 Oct; 28(8):736-45. PubMed ID: 24947176 [Abstract] [Full Text] [Related]
34. Technetium-99m-sestamibi single agent localization versus high resolution ultrasonography for the preoperative localization of parathyroid glands in patients with primary hyperparathyroidism. Billy HT, Rimkus DR, Hartzman S, Latimer RG. Am Surg; 1995 Oct; 61(10):882-8. PubMed ID: 7668462 [Abstract] [Full Text] [Related]
36. [Use of 99mTc-tetrofosmin scintigraphy in the diagnosis of patients with hyperparathyroidism]. Vallejos V, Martín-Comín J, Mora J, González MT, Rafecas A, Muñoz A, Fernández A, Castell M, Ricard Y, Ramos M. Rev Esp Med Nucl; 1998 Oct; 17(2):94-101. PubMed ID: 9611279 [Abstract] [Full Text] [Related]