These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


70 related items for PubMed ID: 8682545

  • 1. A new double modeling approach for dynamic cardiac PET studies using noise and spillover contaminated LV measurements.
    Feng D, Li X, Huang SC.
    IEEE Trans Biomed Eng; 1996 Mar; 43(3):319-27. PubMed ID: 8682545
    [Abstract] [Full Text] [Related]

  • 2. Correction of spillover radioactivities for estimation of the blood time-activity curve from the imaged LV chamber in cardiac dynamic FDG PET studies.
    Lin KP, Huang SC, Choi Y, Brunken RC, Schelbert HR, Phelps ME.
    Phys Med Biol; 1995 Apr; 40(4):629-42. PubMed ID: 7610118
    [Abstract] [Full Text] [Related]

  • 3.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 4.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 5.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 6. Dual spillover problem in the myocardial septum with nitrogen-13-ammonia flow quantitation.
    Hove JD, Gambhir SS, Kofoed KF, Kelbaek H, Schelbert HR, Phelps ME.
    J Nucl Med; 1998 Apr; 39(4):591-8. PubMed ID: 9544662
    [Abstract] [Full Text] [Related]

  • 7. Simple noninvasive quantification method for measuring myocardial glucose utilization in humans employing positron emission tomography and fluorine-18 deoxyglucose.
    Gambhir SS, Schwaiger M, Huang SC, Krivokapich J, Schelbert HR, Nienaber CA, Phelps ME.
    J Nucl Med; 1989 Mar; 30(3):359-66. PubMed ID: 2786939
    [Abstract] [Full Text] [Related]

  • 8. A computer simulation study on the effects of input function measurement noise in tracer kinetic modeling with positron emission tomography (PET).
    Feng D, Wang X.
    Comput Biol Med; 1993 Jan; 23(1):57-68. PubMed ID: 8467639
    [Abstract] [Full Text] [Related]

  • 9.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 10. [Glucose metabolism in ischemic myocardium: quantitative imaging using positron emission tomography].
    Takahashi A, Ono Y, Sudo M, Araki K, Shishido F, Uemura K, Kadowaki K, Kumagai T.
    J Cardiogr; 1986 Jun; 16(2):291-9. PubMed ID: 3495606
    [Abstract] [Full Text] [Related]

  • 11. Measurement of input functions in rodents: challenges and solutions.
    Laforest R, Sharp TL, Engelbach JA, Fettig NM, Herrero P, Kim J, Lewis JS, Rowland DJ, Tai YC, Welch MJ.
    Nucl Med Biol; 2005 Oct; 32(7):679-85. PubMed ID: 16243642
    [Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 15. A computer simulation study on the input function sampling schedules in tracer kinetic modeling with positron emission tomography (PET).
    Feng D, Wang X, Yan H.
    Comput Methods Programs Biomed; 1994 Nov; 45(3):175-86. PubMed ID: 7705075
    [Abstract] [Full Text] [Related]

  • 16. Image-derived input functions for determination of MRGlu in cardiac (18)F-FDG PET scans.
    van der Weerdt AP, Klein LJ, Boellaard R, Visser CA, Visser FC, Lammertsma AA.
    J Nucl Med; 2001 Nov; 42(11):1622-9. PubMed ID: 11696630
    [Abstract] [Full Text] [Related]

  • 17. Spillover and partial-volume correction for image-derived input functions for small-animal 18F-FDG PET studies.
    Fang YH, Muzic RF.
    J Nucl Med; 2008 Apr; 49(4):606-14. PubMed ID: 18344438
    [Abstract] [Full Text] [Related]

  • 18. Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography.
    Feng D, Huang SC, Wang X.
    Int J Biomed Comput; 1993 Mar; 32(2):95-110. PubMed ID: 8449593
    [Abstract] [Full Text] [Related]

  • 19. A technique for extracting physiological parameters and the required input function simultaneously from PET image measurements: theory and simulation study.
    Feng D, Wong KP, Wu CM, Siu WC.
    IEEE Trans Inf Technol Biomed; 1997 Dec; 1(4):243-54. PubMed ID: 11020827
    [Abstract] [Full Text] [Related]

  • 20. Derivation of input function from FDG-PET studies in small hearts.
    Wu HM, Huang SC, Allada V, Wolfenden PJ, Schelbert HR, Phelps ME, Hoh CK.
    J Nucl Med; 1996 Oct; 37(10):1717-22. PubMed ID: 8862318
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 4.