These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
91 related items for PubMed ID: 8741548
1. [The problem of 19 mm St. Jude Medical valve prosthesis in the small aortic annuls--19 mm St. Jude Medical valve vs 23 mm St. Jude Medical valve]. Yamanaka K, Ando F, Okamoto F, Hanada M, Sasahashi N, Hanada T, Nishigaki Y, Matsuno S. Nihon Kyobu Geka Gakkai Zasshi; 1996 Jul; 44(7):906-11. PubMed ID: 8741548 [Abstract] [Full Text] [Related]
2. A 5 1/2 year experience with the St. Jude Medical cardiac valve prosthesis. Early and late results of 737 valve replacements in 671 patients. Baudet EM, Oca CC, Roques XF, Laborde MN, Hafez AS, Collot MA, Ghidoni IM. J Thorac Cardiovasc Surg; 1985 Jul; 90(1):137-44. PubMed ID: 3874324 [Abstract] [Full Text] [Related]
3. Regression of left ventricular hypertrophy after aortic valve replacement in patients over 55 years old with different valve types. Ozatik MA, Göl MK, Yildiz U, Göksel S, Yurdakök O, Yavas S, Tufekcioğlu O, Sener E, Tasdemir O. Med Sci Monit; 2003 Feb; 9(2):CR55-60. PubMed ID: 12601287 [Abstract] [Full Text] [Related]
4. [The long-term results of isolated aortic valve replacement with 19 mm prostheses]. Nakamura T, Shimamoto M, Yamazaki F, Yoshimura T, Itoi S, Ueno T, Oyanagi H, Nakai M, Shinozaki T. Kyobu Geka; 1995 Sep; 48(10):824-8. PubMed ID: 7474579 [Abstract] [Full Text] [Related]
5. Impact of valve prosthesis-patient mismatch on long-term survival and left ventricular mass regression after aortic valve replacement for aortic stenosis. Kato Y, Suehiro S, Shibata T, Sasaki Y, Hirai H. J Card Surg; 2007 Sep; 22(4):314-9. PubMed ID: 17661773 [Abstract] [Full Text] [Related]
7. Impact of postoperative blood pressure control on regression of left ventricular mass following valve replacement for aortic stenosis. Imanaka K, Kohmoto O, Nishimura S, Yokote Y, Kyo S. Eur J Cardiothorac Surg; 2005 Jun; 27(6):994-9. PubMed ID: 15896607 [Abstract] [Full Text] [Related]
8. Indexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly. Roscitano A, Benedetto U, Sciangula A, Merico E, Barberi F, Bianchini R, Tonelli E, Sinatra R. Eur J Cardiothorac Surg; 2006 Feb; 29(2):139-43. PubMed ID: 16376565 [Abstract] [Full Text] [Related]
9. [Long-term results of the 19 mm low-profile bileaflet valve prosthesis in the small aortic anulus]. Terada Y, Shiihara H, Ino T, Wanibuchi Y, Furuta S. Nihon Kyobu Geka Gakkai Zasshi; 1989 Mar; 37(3):470-7. PubMed ID: 2768922 [Abstract] [Full Text] [Related]
10. [Late complications following Björk-Shiley and St. Jude Medical heart valve replacement]. Horstkotte D, Körfer R, Budde T, Haerten K, Schulte HD, Bircks W, Loogen F. Z Kardiol; 1983 May; 72(5):251-61. PubMed ID: 6880335 [Abstract] [Full Text] [Related]
11. Excellent long-term results of cardiac valve replacement with the St Jude Medical valve prosthesis. Smith JA, Westlake GW, Mullerworth MH, Skillington PD, Tatoulis J. Circulation; 1993 Nov; 88(5 Pt 2):II49-54. PubMed ID: 8222196 [Abstract] [Full Text] [Related]
12. [Long-term results of conventional aortic valve replacement for small aortic annulus]. Miura Y, Miyairi T, Kitamura T, Kigawa I, Fukuda S. Kyobu Geka; 2006 Apr; 59(4):306-12. PubMed ID: 16613149 [Abstract] [Full Text] [Related]
13. An alternative option for elderly patients with a small aortic annulus: the 16 mm ATS valve. Nakamura Y, Nakano K, Tagusari O, Kataoka G, Seike Y, Domoto S, Ito Y. J Heart Valve Dis; 2009 Nov; 18(6):691-7. PubMed ID: 20099719 [Abstract] [Full Text] [Related]
14. Seven-year results with the St Jude Medical Silzone mechanical prosthesis. Jamieson WR, Fradet GJ, Abel JG, Janusz MT, Lichtenstein SV, MacNab JS, Stanford EA, Chan F. J Thorac Cardiovasc Surg; 2009 May; 137(5):1109-15.e2. PubMed ID: 19379975 [Abstract] [Full Text] [Related]
15. Long term clinical results with 19 mm or 21 mm standard aortic St. Jude Medical prosthesis. Hayashi J, Nakazawa S, Okazaki H, Ohzeki H, Saito A, Moro H, Yamamoto K, Eguchi S. J Heart Valve Dis; 1994 Sep; 3(5):537-42. PubMed ID: 8000589 [Abstract] [Full Text] [Related]
16. Antiplatelet drugs and the incidence of thromboembolic complications of the St. Jude Medical aortic prosthesis in patients with rheumatic heart disease. Ribeiro PA, Al Zaibag M, Idris M, Al Kasab S, Davies G, Mashat E, Wareham E, Al Fagih M. J Thorac Cardiovasc Surg; 1986 Jan; 91(1):92-8. PubMed ID: 3941564 [Abstract] [Full Text] [Related]
17. [Early and late results of St. Jude Medical prosthesis in aortic and mitral portion]. Kuboyama I, Sese A, Masaki H, Kohda Y, Ueno Y, Imoto H. Rinsho Kyobu Geka; 1989 Aug; 9(4):374-80. PubMed ID: 9301945 [Abstract] [Full Text] [Related]
18. Long-term follow up of patients undergoing reoperative surgery with aortic or mitral valve replacement using a St. Jude Medical prosthesis. Emery RW, Krogh CC, McAdams S, Emery AM, Holter AR. J Heart Valve Dis; 2010 Jul; 19(4):473-84. PubMed ID: 20845896 [Abstract] [Full Text] [Related]
19. [Rest and exercise performance of allografts, Bicer valves and St. Jude Medical valves in the aortic position]. Hasegawa J, Kitamura S, Kawachi K, Kawata T, Niwaya K, Kameda Y, Mizuguchi K, Kobayashi S, Yoshida Y. Nihon Kyobu Geka Gakkai Zasshi; 1995 Aug; 43(8):1132-7. PubMed ID: 7594847 [Abstract] [Full Text] [Related]
20. Long-term results with the Biocor-SJM stentless porcine aortic bioprosthesis. Vrandecic M, Fantini FA, Filho BG, de O, da C, Vrandecic E. J Heart Valve Dis; 2002 Jan; 11(1):47-53. PubMed ID: 11843505 [Abstract] [Full Text] [Related] Page: [Next] [New Search]