These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
92 related items for PubMed ID: 8766128
1. [Experimental studies on the role of intramedullary alignment rods in the etiology of fat embolisms in knee endoprostheses]. Gleitz M, Hopf T, Hess T. Z Orthop Ihre Grenzgeb; 1996; 134(3):254-9. PubMed ID: 8766128 [Abstract] [Full Text] [Related]
4. [Intramedullary pressure in the femur during boring and nailing with modern compression interlocking nails--risk of fat embolism?]. Hopf T, Gleitz M, Hess T. Unfallchirurg; 1994 Sep; 97(9):458-61. PubMed ID: 7973749 [Abstract] [Full Text] [Related]
5. Blood-gas and circulatory changes during total knee replacement. Role of the intramedullary alignment rod. Fahmy NR, Chandler HP, Danylchuk K, Matta EB, Sunder N, Siliski JM. J Bone Joint Surg Am; 1990 Jan; 72(1):19-26. PubMed ID: 2104854 [Abstract] [Full Text] [Related]
6. [Pathophysiology of fat embolisms in orthopedics and traumatology]. Hofmann S, Huemer G, Kratochwill C, Koller-Strametz J, Hopf R, Schlag G, Salzer M. Orthopade; 1995 Apr; 24(2):84-93. PubMed ID: 7753543 [Abstract] [Full Text] [Related]
7. Fat embolism syndrome following the intramedullary alignment guide in total knee arthroplasty. Caillouette JT, Anzel SH. Clin Orthop Relat Res; 1990 Feb; (251):198-9. PubMed ID: 2295174 [Abstract] [Full Text] [Related]
9. [The effect of bone marrow embolization on the choice of procedure in the stabilization of femoral fractures]. Wenda K, Runkel M, Rudig L, Degreif J. Orthopade; 1995 Apr; 24(2):151-63. PubMed ID: 7753540 [Abstract] [Full Text] [Related]
10. Unusual complication associated with femoral intramedullary alignment guide in total knee arthroplasty. Yau WP, Ng TP, Chiu KY. J Arthroplasty; 2001 Feb; 16(2):247-9. PubMed ID: 11222904 [Abstract] [Full Text] [Related]
11. [Intramedullary pressure in intramedullary nailing of the femur and tibia]. Heim D, Schlegel U, Perren SM. Helv Chir Acta; 1994 Apr; 60(4):605-10. PubMed ID: 8034541 [Abstract] [Full Text] [Related]
12. Incidence of fat embolism syndrome after cemented or cementless bilateral simultaneous and unilateral total knee arthroplasty. Kim YH. J Arthroplasty; 2001 Sep; 16(6):730-9. PubMed ID: 11547371 [Abstract] [Full Text] [Related]
13. The influence of a one-step reamer-irrigator-aspirator technique on the intramedullary pressure in the pig femur. Husebye EE, Lyberg T, Madsen JE, Eriksen M, Røise O. Injury; 2006 Oct; 37(10):935-40. PubMed ID: 16934266 [Abstract] [Full Text] [Related]
14. Fatal fat embolism during cemented total knee arthroplasty: a case report. Orsini EC, Richards RR, Mullen JM. Can J Surg; 1986 Sep; 29(5):385-6. PubMed ID: 3756668 [Abstract] [Full Text] [Related]
15. Intramedullary pressure and pulmonary function during total knee arthroplasty. Ries MD, Rauscher LA, Hoskins S, Lott D, Richman JA, Lynch F. Clin Orthop Relat Res; 1998 Nov; (356):154-60. PubMed ID: 9917680 [Abstract] [Full Text] [Related]
16. [Modified surgical technique for reduction of bone marrow spilling in cement-free hip endoprosthesis]. Hofmann S, Hopf R, Huemer G, Kratochwill C, Koller-Strametz J, Schlag G, Salzer M. Orthopade; 1995 Apr; 24(2):130-7. PubMed ID: 7753537 [Abstract] [Full Text] [Related]
17. An in vitro study of femoral intramedullary pressures during hip replacement using modern cement technique. Song Y, Goodman SB, Jaffe RA. Clin Orthop Relat Res; 1994 May; (302):297-304. PubMed ID: 8168317 [Abstract] [Full Text] [Related]
18. Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty. Novotny J, Gonzalez MH, Amirouche FM, Li YC. J Arthroplasty; 2001 Aug; 16(5):641-7. PubMed ID: 11503125 [Abstract] [Full Text] [Related]
19. Curvature of the femur and the proximal entry point for an intramedullary rod. Harper MC, Carson WL. Clin Orthop Relat Res; 1987 Jul; (220):155-61. PubMed ID: 3594986 [Abstract] [Full Text] [Related]
20. [Influence of prosthesis design on intramedullary pressure formation in femur shaft implants of cemented hip endoprostheses]. Beck A, Strecker W, Gebhard F, Arand M, Krischak G, Kinzl L. Unfallchirurg; 2001 Dec; 104(12):1140-4. PubMed ID: 11803720 [Abstract] [Full Text] [Related] Page: [Next] [New Search]