These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


219 related items for PubMed ID: 8801158

  • 1. Endopap-versus Pipelle-sampling in the diagnosis of postmenopausal endometrial disease.
    Van den Bosch T, Vandendael A, Wranz PA, Lombard CJ.
    Eur J Obstet Gynecol Reprod Biol; 1996 Jan; 64(1):91-4. PubMed ID: 8801158
    [Abstract] [Full Text] [Related]

  • 2. Outpatient endometrial sampling with the Pipelle curette.
    Ben-Baruch G, Seidman DS, Schiff E, Moran O, Menczer J.
    Gynecol Obstet Invest; 1994 Jan; 37(4):260-2. PubMed ID: 8050731
    [Abstract] [Full Text] [Related]

  • 3. Pipelle versus fractional curettage for the endometrial sampling in postmenopausal women.
    Bunyavejchevin S, Triratanachat S, Kankeow K, Limpaphayom KK.
    J Med Assoc Thai; 2001 Jun; 84 Suppl 1():S326-30. PubMed ID: 11529353
    [Abstract] [Full Text] [Related]

  • 4. The accuracy of endometrial sampling in women with postmenopausal bleeding: a systematic review and meta-analysis.
    van Hanegem N, Prins MM, Bongers MY, Opmeer BC, Sahota DS, Mol BW, Timmermans A.
    Eur J Obstet Gynecol Reprod Biol; 2016 Feb; 197():147-55. PubMed ID: 26748390
    [Abstract] [Full Text] [Related]

  • 5. Combining vaginal ultrasonography and office endometrial sampling in the diagnosis of endometrial disease in postmenopausal women.
    Van den Bosch T, Vandendael A, Van Schoubroeck D, Wranz PA, Lombard CJ.
    Obstet Gynecol; 1995 Mar; 85(3):349-52. PubMed ID: 7862370
    [Abstract] [Full Text] [Related]

  • 6. Comparison the Diagnostic Value of Dilatation and Curettage Versus Endometrial Biopsy by Pipelle--a Clinical Trial.
    Sanam M, Majid MM.
    Asian Pac J Cancer Prev; 2015 Mar; 16(12):4971-5. PubMed ID: 26163624
    [Abstract] [Full Text] [Related]

  • 7.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 8.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 9.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 10. Investigating vaginal bleeding in postmenopausal women found to have an endometrial thickness of equal to or greater than 10 mm on ultrasonography.
    Turnbull HL, Akrivos N, Simpson P, Duncan TJ, Nieto JJ, Burbos N.
    Arch Gynecol Obstet; 2017 Feb; 295(2):445-450. PubMed ID: 27909879
    [Abstract] [Full Text] [Related]

  • 11. The role of Pipelle Mark II sampling in endometrial disease diagnosis.
    Polena V, Mergui JL, Zerat L, Sananes S.
    Eur J Obstet Gynecol Reprod Biol; 2007 Oct; 134(2):233-7. PubMed ID: 17029754
    [Abstract] [Full Text] [Related]

  • 12. Positive predictive value of endometrial polyps in Pipelle aspiration sampling: a histopathological study of 195 cases.
    Seto MT, Ip PP, Ngu SF, Cheung AN, Pun TC.
    Eur J Obstet Gynecol Reprod Biol; 2016 Aug; 203():12-5. PubMed ID: 27219202
    [Abstract] [Full Text] [Related]

  • 13. The performance of Pipelle endometrial sampling in a dedicated postmenopausal bleeding clinic.
    Elsandabesee D, Greenwood P.
    J Obstet Gynaecol; 2005 Jan; 25(1):32-4. PubMed ID: 16147690
    [Abstract] [Full Text] [Related]

  • 14. Factors affecting adequacy of Pipelle and Tao Brush endometrial sampling.
    Williams AR, Brechin S, Porter AJ, Warner P, Critchley HO.
    BJOG; 2008 Jul; 115(8):1028-36. PubMed ID: 18651884
    [Abstract] [Full Text] [Related]

  • 15.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 16. Ultrasound examination of the endometrium before and after Pipelle endometrial sampling.
    Van den Bosch T, Van Schoubroeck D, Ameye L, Van Huffel S, Timmerman D.
    Ultrasound Obstet Gynecol; 2005 Sep; 26(3):283-6. PubMed ID: 16082721
    [Abstract] [Full Text] [Related]

  • 17. Cost-effectiveness analysis of biopsy strategies for endometrial cancer diagnosis in women with postmenopausal bleeding: Pipelle sampling curette versus dilatation & curettage.
    Yi Y, Bryce CL, Adambekov S, Edwards RP, Goughnour SL, Linkov F.
    Gynecol Oncol; 2018 Jul; 150(1):112-118. PubMed ID: 29747864
    [Abstract] [Full Text] [Related]

  • 18. Which is the best technique for endometrial sampling? Aspiration (pipelle) versus dilatation and curettage (D&C).
    Demirkiran F, Yavuz E, Erenel H, Bese T, Arvas M, Sanioglu C.
    Arch Gynecol Obstet; 2012 Nov; 286(5):1277-82. PubMed ID: 22766754
    [Abstract] [Full Text] [Related]

  • 19. Outpatient endometrial biopsy: the pipelle.
    Youssif SN, McMillan DL.
    Br J Hosp Med; 2012 Nov; 54(5):198-201. PubMed ID: 8528525
    [Abstract] [Full Text] [Related]

  • 20. The accuracy of endometrial Pipelle sampling with and without sonographic measurement of endometrial thickness.
    Goldchmit R, Katz Z, Blickstein I, Caspi B, Dgani R.
    Obstet Gynecol; 1993 Nov; 82(5):727-30. PubMed ID: 8414316
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 11.