These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Environmental microbial challenges to an aseptic Blow-Fill-Seal process--a practical study. Jones DJ, Topping P, Sharp J. PDA J Pharm Sci Technol; 1995; 49(5):226-34. PubMed ID: 7489196 [Abstract] [Full Text] [Related]
3. Airborne microbial challenges of Blow/Fill/Seal equipment: a case study. Bradley A, Probert SP, Sinclair CS, Tallentire A. J Parenter Sci Technol; 1991; 45(4):187-92. PubMed ID: 1770413 [Abstract] [Full Text] [Related]
4. Current practice in the operation and validation of aseptic blow-fill-seal processes. Ljungqvist B, Reinmüller B, Löfgren A, Dewhurst E. PDA J Pharm Sci Technol; 2006; 60(4):254-8. PubMed ID: 17089694 [Abstract] [Full Text] [Related]
5. Challenges to a blow/fill/seal process with airborne microorganisms having different resistances to dry heat. Poisson P, Sinclair CS, Tallentire A. PDA J Pharm Sci Technol; 2006; 60(5):323-30. PubMed ID: 17089701 [Abstract] [Full Text] [Related]
6. Impact of Blow/Fill/Seal process variables in determining rate of vial contamination by air dispersed microorganisms. Leo F, Poisson P, Sinclair CS, Tallentire A. PDA J Pharm Sci Technol; 2005; 59(5):320-31. PubMed ID: 16316067 [Abstract] [Full Text] [Related]
7. The influence of clean room design on product contamination. Whyte W. J Parenter Sci Technol; 1984; 38(3):103-8. PubMed ID: 6747777 [No Abstract] [Full Text] [Related]
8. Airborne contamination during blow-fill-seal pharmaceutical production. Whyte W, Matheis W, Dean-Netcher M, Edwards A. PDA J Pharm Sci Technol; 1998; 52(3):89-99. PubMed ID: 9691671 [Abstract] [Full Text] [Related]
9. Performance of blow/fill/seal equipment under controlled airborne microbial challenges. Sinclair CS, Tallentire A. PDA J Pharm Sci Technol; 1995; 49(6):294-9. PubMed ID: 8581461 [Abstract] [Full Text] [Related]
10. Design control and validation of a facility for sterile clinical trial preparations. Staines L. J Parenter Sci Technol; 1984; 38(3):109-14. PubMed ID: 6747778 [No Abstract] [Full Text] [Related]
11. [Flow of laminar air: use in sterile rooms]. Lumini E. Boll Chim Farm; 1975 Jul; 114(7):361-74. PubMed ID: 1164445 [No Abstract] [Full Text] [Related]
12. Evaluation of Blow/Fill/Seal extrusion through processing polymer contaminated with bacterial spores and endotoxin. Leo F, Poisson P, Sinclair CS, Tallentire A. PDA J Pharm Sci Technol; 2004 Jul; 58(3):147-58. PubMed ID: 15233254 [Abstract] [Full Text] [Related]
13. A new laminar flow biological contamination control hood. Marsh RC. Bull Parenter Drug Assoc; 1970 Jul; 24(3):134-47. PubMed ID: 5422902 [No Abstract] [Full Text] [Related]
14. Some observations on airborne particles in the critical areas of a blow-fill-seal machine. Sundström S, Ljungqvist B, Reinmüller B. PDA J Pharm Sci Technol; 2009 Jul; 63(1):71-80. PubMed ID: 19455943 [Abstract] [Full Text] [Related]
15. A multicentred investigation of clean air requirements for terminally sterilized pharmaceuticals. Whyte W. J Parenter Sci Technol; 1983 Jul; 37(4):138-44. PubMed ID: 6620047 [No Abstract] [Full Text] [Related]
16. [Microbiological in-process control in drug manufacture]. Seyfarth VH. Arzneimittelforschung; 1985 Jul; 35(1A):205-16. PubMed ID: 4039162 [Abstract] [Full Text] [Related]
17. Panel discussion: Environmental sampling in an aseptic environment. III. Cross contamination control. Elias WF. Bull Parenter Drug Assoc; 1974 Jul; 28(6):263-9. PubMed ID: 4455322 [No Abstract] [Full Text] [Related]
18. In support of settle plates. Whyte W. PDA J Pharm Sci Technol; 1996 Jul; 50(4):201-4. PubMed ID: 8810833 [Abstract] [Full Text] [Related]