These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


312 related items for PubMed ID: 8883656

  • 1. Spinal cord lesions in patients with multiple sclerosis: comparison of MR pulse sequences.
    Hittmair K, Mallek R, Prayer D, Schindler EG, Kollegger H.
    AJNR Am J Neuroradiol; 1996 Sep; 17(8):1555-65. PubMed ID: 8883656
    [Abstract] [Full Text] [Related]

  • 2. A comparison of sagittal short T1 inversion recovery and T2-weighted FSE sequences for detection of multiple sclerosis spinal cord lesions.
    Nayak NB, Salah R, Huang JC, Hathout GM.
    Acta Neurol Scand; 2014 Mar; 129(3):198-203. PubMed ID: 23980614
    [Abstract] [Full Text] [Related]

  • 3. Comparison of a conventional cardiac-triggered dual spin-echo and a fast STIR sequence in detection of spinal cord lesions in multiple sclerosis.
    Bot JC, Barkhof F, Lycklama à Nijeholt GJ, Bergers E, Polman CH, Adèr HJ, Castelijns JA.
    Eur Radiol; 2000 Mar; 10(5):753-8. PubMed ID: 10823627
    [Abstract] [Full Text] [Related]

  • 4. Short tau inversion recovery fast spin-echo (fast STIR) imaging of the spinal cord in multiple sclerosis.
    Thorpe JW, MacManus DG, Kendall BE, Tofts PS, Barker GJ, McDonald WI, Miller DH.
    Magn Reson Imaging; 1994 Mar; 12(7):983-9. PubMed ID: 7997103
    [Abstract] [Full Text] [Related]

  • 5. Comparison of two MR sequences for the detection of multiple sclerosis lesions in the spinal cord.
    Lycklama à Nijeholt GJ, Barkhof F, Castelijns JA, van Waesberghe JH, Valk J, Jongen PJ, Hommes OR.
    AJNR Am J Neuroradiol; 1996 Sep; 17(8):1533-8. PubMed ID: 8883653
    [Abstract] [Full Text] [Related]

  • 6. Liver MR imaging: comparison of respiratory triggered fast spin echo with T2-weighted spin-echo and inversion recovery.
    Keogan MT, Spritzer CE, Paulson EK, Paine SS, Harris L, Dahlke JL, MacFall JR.
    Abdom Imaging; 1996 Sep; 21(5):433-9. PubMed ID: 8832865
    [Abstract] [Full Text] [Related]

  • 7. Comparison of three MR sequences for the detection of cervical cord lesions in patients with multiple sclerosis.
    Rocca MA, Mastronardo G, Horsfield MA, Pereira C, Iannucci G, Colombo B, Moiola L, Comi G, Filippi M.
    AJNR Am J Neuroradiol; 1999 Oct; 20(9):1710-6. PubMed ID: 10543646
    [Abstract] [Full Text] [Related]

  • 8. Sagittal MR of multiple sclerosis in the spinal cord: fast versus conventional spin-echo imaging.
    Lycklama à Nijeholt GJ, Castelijns JA, Weerts J, Adèr H, van Waesberghe JH, Polman C, Barkhof F.
    AJNR Am J Neuroradiol; 1998 Feb; 19(2):355-60. PubMed ID: 9504494
    [Abstract] [Full Text] [Related]

  • 9. The low sensitivity of fluid-attenuated inversion-recovery MR in the detection of multiple sclerosis of the spinal cord.
    Keiper MD, Grossman RI, Brunson JC, Schnall MD.
    AJNR Am J Neuroradiol; 1997 Feb; 18(6):1035-9. PubMed ID: 9194430
    [Abstract] [Full Text] [Related]

  • 10. Comparison of MERGE and axial T2-weighted fast spin-echo sequences for detection of multiple sclerosis lesions in the cervical spinal cord.
    Martin N, Malfair D, Zhao Y, Li D, Traboulsee A, Lang D, Vertinsky AT.
    AJR Am J Roentgenol; 2012 Jul; 199(1):157-62. PubMed ID: 22733907
    [Abstract] [Full Text] [Related]

  • 11. A comparison of conventional spin-echo and fast spin-echo in the detection of multiple sclerosis.
    Patola WB, Coulter BA, Chipperfield PM, Lingawi SS.
    J Magn Reson Imaging; 2001 May; 13(5):657-67. PubMed ID: 11329186
    [Abstract] [Full Text] [Related]

  • 12. Comparison of T1-weighted fast spin-echo and T1-weighted fluid-attenuated inversion recovery images of the lumbar spine at 3.0 Tesla.
    Lavdas E, Vlychou M, Arikidis N, Kapsalaki E, Roka V, Fezoulidis IV.
    Acta Radiol; 2010 Apr; 51(3):290-5. PubMed ID: 20170294
    [Abstract] [Full Text] [Related]

  • 13. Comparison of Sagittal FSE T2, STIR, and T1-Weighted Phase-Sensitive Inversion Recovery in the Detection of Spinal Cord Lesions in MS at 3T.
    Alcaide-Leon P, Pauranik A, Alshafai L, Rawal S, Oh J, Montanera W, Leung G, Bharatha A.
    AJNR Am J Neuroradiol; 2016 May; 37(5):970-5. PubMed ID: 26797141
    [Abstract] [Full Text] [Related]

  • 14. Comparison of MRI pulse sequences for investigation of lesions of the cervical spinal cord.
    Campi A, Pontesilli S, Gerevini S, Scotti G.
    Neuroradiology; 2000 Sep; 42(9):669-75. PubMed ID: 11071441
    [Abstract] [Full Text] [Related]

  • 15. Detection of multiple sclerosis lesions in the cervical cord: which of the MAGNIMS 'mandatory' non-gadolinium enhanced sagittal sequences is optimal at 3T?
    Chang CA, Chong AL, Chandra RV, Butler E, Rajendran D, Chuah K, Stuckey S.
    Neuroradiol J; 2021 Dec; 34(6):600-606. PubMed ID: 34014786
    [Abstract] [Full Text] [Related]

  • 16. Axial 3D gradient-echo imaging for improved multiple sclerosis lesion detection in the cervical spinal cord at 3T.
    Ozturk A, Aygun N, Smith SA, Caffo B, Calabresi PA, Reich DS.
    Neuroradiology; 2013 Mar; 55(4):431-9. PubMed ID: 23208410
    [Abstract] [Full Text] [Related]

  • 17. Imaging of the spinal cord and brain in multiple sclerosis: a comparative study between fast FLAIR and fast spin echo.
    Stevenson VL, Gawne-Cain ML, Barker GJ, Thompson AJ, Miller DH.
    J Neurol; 1997 Feb; 244(2):119-24. PubMed ID: 9120494
    [Abstract] [Full Text] [Related]

  • 18. MR evaluation of vertebral metastases: T1-weighted, short-inversion-time inversion recovery, fast spin-echo, and inversion-recovery fast spin-echo sequences.
    Mehta RC, Marks MP, Hinks RS, Glover GH, Enzmann DR.
    AJNR Am J Neuroradiol; 1995 Feb; 16(2):281-8. PubMed ID: 7726074
    [Abstract] [Full Text] [Related]

  • 19. Comparison of MRI sequences for evaluation of multiple sclerosis of the cervical spinal cord at 3 T.
    Philpott C, Brotchie P.
    Eur J Radiol; 2011 Dec; 80(3):780-5. PubMed ID: 21041051
    [Abstract] [Full Text] [Related]

  • 20. Fast spin-echo and fast fluid-attenuated inversion-recovery versus conventional spin-echo sequences for MR quantification of multiple sclerosis lesions.
    Bastianello S, Bozzao A, Paolillo A, Giugni E, Gasperini C, Koudriavtseva T, Millefiorini E, Horsfield MA, Colonnese C, Toni D, Fiorelli M, Pozzilli C, Bozzao L.
    AJNR Am J Neuroradiol; 1997 Apr; 18(4):699-704. PubMed ID: 9127033
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 16.